The DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.
Contact Lens Sensors in Ocular Diagnostics
Abstract
Contact lenses as a minimally invasive platform for diagnostics and drug delivery have emerged in recent years. Contact lens sensors have been developed for analyzing the glucose composition of tears as a surrogate for blood glucose monitoring and for the diagnosis of glaucoma by measuring intraocular pressure. However, the eye offers a wider diagnostic potential as a sensing site and therefore contact lens sensors have the potential to improve the diagnosis and treatment of many diseases and conditions. With advances in polymer synthesis, electronics and micro/nanofabrication, contact lens sensors can be produced to quantify the concentrations of many biomolecules in ocular fluids. Non‐ or minimally invasive contact lens sensors can be used directly in a clinical or point‐of‐care setting to monitor a disease state continuously. This article reviews the state‐of‐the‐art in contact lens sensor fabrication, their detection, wireless powering, and readout mechanisms, and integration with mobile devices and smartphones. High‐volume manufacturing considerations of contact lenses are also covered and a case study of an intraocular pressure contact lens sensor is provided as an example of a successful product. This Review further analyzes the contact lens market and the FDA regulatory requirements for commercialization of contact lens sensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Blood and tear fluid have a compositional difference due to the blood–tear barrier; however, the concentrations of analytes in both fluids have a relationship as a result of plasma leakage.57”
From Wearables in Medicine (2018) · cites this paper as [57]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [94]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [94]
In the citing paper
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [94]
In the citing paper
“Given this background, a smart contact lens is a promising example of a wearable, health monitoring device (13, 14).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [13]
In the citing paper
“By considering the correlation between the tear glucose level and blood glucose level (15), a glucose sensor fitted on a contact lens can provide the noninvasive monitoring of user’s glucose levels from tear fluids with a consideration of the lag time between tear glucose level and blood glucose level in the range of 10 to 20 min (13–16).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [13]
In the citing paper
“In addition, the user’s tears can be collected in the contact lens by completely natural means, such as normal secretion and blinking, and used to assess various biomarkers found in the blood, such as glucose, cholesterol, sodium ions, and potassium ions (13).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [13]
Citations
Cites
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Fluorescence Spectroscopy of Single Biomolecules
Weiss, S. (1999) · Science · doi:10.1126/science.283.5408.1676 · Cited by 2,060
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA · doi:10.1001/jama.1990.03450210108045 · Cited by 2,040
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 2,017
Self-citationClinical Methods: The History, Physical, and Laboratory Examinations
(1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-7-563_2 · Cited by 1,408
Geigy, J. R. (1981) · Medical Entomology and Zoology · Cited by 1,221
The renaissance of fluorescence resonance energy transfer.
Selvin, P. R. (2000) · Nature Structural Biology · doi:10.1038/78948 · Cited by 998
Functional aspects of the tear film lipid layer
Bron, A. J., Tiffany, J. M., Gouveia, S. M., Yokoi, N., & Voon, L. W. (2003) · Experimental Eye Research · doi:10.1016/j.exer.2003.09.019 · Cited by 784
Solomon, A., Dursun, D., Liu, Z., Xie, Y., Macrì, A., & Pflugfelder, S. C. (2001) · PubMed · Cited by 721
Pflugfelder, S. C., Jones, D., Ji, Z., Afonso, A. A., & Monroy, D. C. (1999) · Current Eye Research · doi:10.1076/ceyr.19.3.201.5309 · Cited by 618
Flagged first, then by citations
Research works printed but not linked: 22
- Novartis International AG Press Release “Novartis to license Google “smart lens” technology” 2014 1.
- Google Press Release “What is Google doing with a smart contact lens?”2014.
- Yan J., 2011, Conf. Proc. IEEE Eng. Med. Biol. Soc
- Brusini P., 2014, Atlas of Glaucoma
- Mochizuki M., 2004, Yamagata Med. J., 22, 9
- Daum K. M., 1982, Invest. Ophthalmol. Vis. Sci., 22, 509
- Green‐Church K. B., 2008, Mol. Vis., 14, 456
- Solomon A., 2001, Invest. Ophthalmol. Vis. Sci., 42, 2283
- Grus F. H., 2002, BMC Ophthalmol., 6, 2
- Tsuji F., 2012, Metabolomics, 2, 1
- McEwen W. K., 1969, Eye, 3, 34
- Chen R., 1996, J. Capillary Electrophor., 3, 243
- Sfuchell R. N., 1984, Invest. Ophthalmol. Vis. Sci., 25, 374
- Fullard R. J., 1990, Invest. Ophthalmol. Vis. Sci., 31, 1119
- Geddes C. D., 2006, Topics in Fluoresence Spectroscopy: Glucose Sensing
- Bennett E. S., 2005, Clinical Contact Lens Practice
- Tseng C.‐K., 2012, 2012 IEEE Sensors
- Domschke A., 2004, Proc. IEEE Sensors 2004
- Newlove D., 1981, Journal of the British Contact Lens Association
- Moezzi A. M., 2014, J. Optom, 1
- Barr J. T., 2005, Clinical Contact Lens Practice
- Schifrin L. G., 1984, The Contact Lens Industry: Structure, Competition and Public Policy (Health Technology Case Study 31)
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,312
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 915
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Metadata
- Authors
- Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H.
- Affiliations
- Imperial College London (GB)
- University of Cambridge (GB)
- The University of Queensland (AU)
- Harvard University (US)
- Corresponding author
- Yetisen, Ali K.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2014-11-17
- Volume
- 4
- Issue
- 6
- Pages
- 792-810
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2055793978
- Cited by
- 466
- References
- 133
- Citations by year
- 2026: 16 · 2025: 29 · 2024: 42 · 2023: 48 · 2022: 47 · 2021: 51 · 2020: 52 · 2019: 50 · 2018: 44 · 2017: 37 · 2016: 24 · 2015: 18 · 2014: 8
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Healthcare Materials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Keywords
- contact lens sensor, ocular diagnostics, glucose monitoring, tear glucose, glaucoma diagnosis, intraocular pressure, minimally invasive diagnosis, point-of-care monitoring, wireless power transfer, smartphone integration, contact lens manufacturing, FDA regulation, ocular drug delivery
- MeSH terms
- Contact Lenses, Electronics, Glaucoma, Humans, Intraocular Pressure, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review