The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Microneedles for Transdermal Biosensing: Current Picture and Future Direction
Open accessAbstract
A novel trend is rapidly emerging in the use of microneedles, which are a miniaturized replica of hypodermic needles with length‐scales of hundreds of micrometers, aimed at the transdermal biosensing of analytes of clinical interest, e.g., glucose, biomarkers, and others. Transdermal biosensing via microneedles offers remarkable opportunities for moving biosensing technologies and biochips from research laboratories to real‐field applications, and envisages easy‐to‐use point‐of‐care microdevices with pain‐free, minimally invasive, and minimal‐training features that are very attractive for both developed and emerging countries. In addition to this, microneedles for transdermal biosensing offer a unique possibility for the development of biochips provided with end‐effectors for their interaction with the biological system under investigation. Direct and efficient collection of the biological sample to be analyzed will then become feasible in situ at the same length‐scale of the other biochip components by minimally trained personnel and in a minimally invasive fashion. This would eliminate the need for blood extraction using hypodermic needles and reduce, in turn, related problems, such as patient infections, sample contaminations, analysis artifacts, etc. The aim here is to provide a thorough and critical analysis of state‐of‐the‐art developments in this novel research trend, and to bridge the gap between microneedles and biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s062 · Cited by 5,491
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Managing preexisting diabetes for pregnancy
Kitzmiller, J. L., Block, J. M., Brown, F. M., Catalano, P. M., Conway, D. L., Coustan, D. R., Gunderson, E. P., Herman, W. H., Hoffman, L. D., Inturrisi, M., et al. (2008) · Diabetes Care · doi:10.2337/dc08-9020 · Cited by 476
Cell-Extracellular Matrix Interactions in Normal and Diseased Skin
Watt, F. M., & Fujiwara, H. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a005124 · Cited by 384
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Choi, J.-W., Wicker, R., Lee, S.-H., Choi, K.-H., Ha, C.-S., & Chung, I. (2009) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2009.05.004 · Cited by 200
Cited by
Zhi, D., Yang, T., O'Hagan, J., Zhang, S., & Donnelly, R. F. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.06.032 · Cited by 637
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Advances in Antimicrobial Microneedle Patches for Combating Infections
Jamaledin, R., Yiu, C. K. Y., Zare, E. N., Niu, L., Vecchione, R., Chen, G., Gu, Z., Tay, F. R., & Makvandi, P. (2020) · Advanced Materials · doi:10.1002/adma.202002129 · Cited by 461
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Metadata
- Authors
- Ventrelli, L., Marsilio Strambini, L., & Barillaro, G.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2015-10-06
- Volume
- 4
- Issue
- 17
- Pages
- 2606-2640
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W1858063304
- Cited by
- 235
- References
- 9
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microneedles for Transdermal Biosensing: Current Picture and Future Direction. https://app.cochat.ai/papers/10.1002/adhm.201500450
- The paper
- Ventrelli, L., Marsilio Strambini, L., & Barillaro, G. (2015). Microneedles for Transdermal Biosensing: Current Picture and Future Direction. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201500450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.