CoChat

Characterization of a Polymer‐Based, Fully Organic Prosthesis for Implantation into the Subretinal Space of the Rat

Open access
Antognazza, Maria Rosa, Di Paolo, Mattia, Ghezzi, Diego, Mete, Maurizio, Di Marco, Stefano, Maya‐Vetencourt, José Fernando, Maccarone, Rita, Desii, Andrea, Di Fonzo, Fabio, Bramini, Mattia, Russo, Angela, Laudato, Lucia, Donelli, Ilaria, Cilli, Michele, Freddi, Giuliano, Pertile, Grazia, Lanzani, Guglielmo, Bisti, Silvia, Benfenati, Fabio · 2016 · Advanced Healthcare Materials
Cited by 88

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Replacement strategies arise as promising approaches in case of inherited retinal dystrophies leading to blindness. A fully organic retinal prosthesis made of conjugated polymers layered onto a silk fibroin substrate is engineered. First, the biophysical and surface properties are characterized; then, the long‐term biocompatibility is assessed after implantation of the organic device in the subretinal space of 3‐months‐old rats for a period of five months. The results indicate a good stability of the subretinal implants over time, with preservation of the physical properties of the polymeric layer and a tight contact with the outer retina. Immunoinflammatory markers detect only a modest tissue reaction to the surgical insult and the foreign body that peaks shortly after surgery and progressively decreases with time to normal levels at five months after implantation. Importantly, the integrity of the polymeric layer in direct contact with the retinal tissue is preserved after five months of implantation. The recovery of the foreign‐body tissue reaction is also associated with a normal b‐wave in the electroretinographic response. The results demonstrate that the device implanted in nondystrophic eyes is well tolerated, highly biocompatible, and suitable as retinal prosthesis in case of photoreceptor degeneration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201600318

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Antognazza, M. R., Di Paolo, M., Ghezzi, D., Mete, M., Di Marco, S., Maya‐Vetencourt, J. F., Maccarone, R., Desii, A., Di Fonzo, F., Bramini, M., Russo, A., Laudato, L., Donelli, I., Cilli, M., Freddi, G., Pertile, G., Lanzani, G., Bisti, S., & Benfenati, F.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2016-05-30
Volume
5
Issue
17
Pages
2271-2282
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2412137904
Cited by
88
References
11
FWCI
5.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.