Characterization of a Polymer‐Based, Fully Organic Prosthesis for Implantation into the Subretinal Space of the Rat
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Replacement strategies arise as promising approaches in case of inherited retinal dystrophies leading to blindness. A fully organic retinal prosthesis made of conjugated polymers layered onto a silk fibroin substrate is engineered. First, the biophysical and surface properties are characterized; then, the long‐term biocompatibility is assessed after implantation of the organic device in the subretinal space of 3‐months‐old rats for a period of five months. The results indicate a good stability of the subretinal implants over time, with preservation of the physical properties of the polymeric layer and a tight contact with the outer retina. Immunoinflammatory markers detect only a modest tissue reaction to the surgical insult and the foreign body that peaks shortly after surgery and progressively decreases with time to normal levels at five months after implantation. Importantly, the integrity of the polymeric layer in direct contact with the retinal tissue is preserved after five months of implantation. The recovery of the foreign‐body tissue reaction is also associated with a normal b‐wave in the electroretinographic response. The results demonstrate that the device implanted in nondystrophic eyes is well tolerated, highly biocompatible, and suitable as retinal prosthesis in case of photoreceptor degeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Silk fibroin biomaterials for tissue regenerations
Kundu, B., Rajkhowa, R., Kundu, S. C., & Wang, X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.043 · Cited by 1,391
Structures, mechanical properties and applications of silk fibroin materials
Koh, L.-D., Cheng, Y., Teng, C.-P., Khin, Y.-W., Loh, X.-J., Tee, S.-Y., Low, M., Ye, E., Yu, H.-D., Zhang, Y.-W., et al. (2015) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2015.02.001 · Cited by 1,241
Organic photonics for communications
Clark, J., & Lanzani, G. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.160 · Cited by 823
Self-citationInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Water-insoluble silk films with silk I structure
Lu, Q., Hu, X., Wang, X., Kluge, J. A., Lu, S., Cebe, P., & Kaplan, D. L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.041 · Cited by 654
Age-related macular degeneration
Coleman, H. R., Chan, C.-C., Ferris, F. L., & Chew, E. Y. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61759-6 · Cited by 542
Müller Glial Cells in Retinal Disease
Bringmann, A., & Wiedemann, P. (2012) · Ophthalmologica · doi:10.1159/000328979 · Cited by 436
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
Gallego, B. I., Salazar, J. J., de Hoz, R., Rojas, B., Ramírez, A. I., Salinas-Navarro, M., Ortín-Martínez, A., Valiente-Soriano, F. J., Avilés-Trigueros, M., Villegas-Perez, M. P., et al. (2012) · Journal of Neuroinflammation · doi:10.1186/1742-2094-9-92 · Cited by 224
Cited by
Choi, C., Choi, M. K., Liu, S., Kim, M., Park, O. K., Im, C., Kim, J., Qin, X., Lee, G. J., Cho, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01824-6 · Cited by 540
A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya-Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Di Paolo, M., Di Marco, S., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 290
Self-citationDesign and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183
Self-citationChenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Self-citationSpatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73
Self-citationVisual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“Photovoltaic polymers and quantum dots (QDs) were proposed as a photoelectrical retinal interface (Bareket-Keren and Hanein, 2014; Gautam et al., 2014; Antognazza et al., 2016; Maya-Vetencourt et al., 2017).”
BackgroundPhotovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63
Self-citationAdvances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Self-citationChenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3913 · Cited by 24
Metadata
- Authors
- Antognazza, M. R., Di Paolo, M., Ghezzi, D., Mete, M., Di Marco, S., Maya‐Vetencourt, J. F., Maccarone, R., Desii, A., Di Fonzo, F., Bramini, M., Russo, A., Laudato, L., Donelli, I., Cilli, M., Freddi, G., Pertile, G., Lanzani, G., Bisti, S., & Benfenati, F.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2016-05-30
- Volume
- 5
- Issue
- 17
- Pages
- 2271-2282
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2412137904
- Cited by
- 88
- References
- 11
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.