The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Stability of molded polydimethylsiloxane microstructures
Abstract
How stable are the features in elastomeric stamps—as used in microcontact printing (μCP) and micromolding in capillaries (MIMIC)—during their formation and subsequent application? Their stability is examined with respect to aspect ration and forces during handling. In the Figure, lines in the structure (gold on silicon), produced using an elastomeric stamp, can be seen to have merged into larger ensembles.magnified image
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imprint Lithography with 25-Nanometer Resolution
Chou, S. Y., Krauss, P. R., & Renstrom, P. J. (1996) · Science · doi:10.1126/science.272.5258.85 · Cited by 2,277
Kumar, A., & Whitesides, G. M. (1993) · Applied Physics Letters · doi:10.1063/1.110628 · Cited by 1,605
Patterning Self-Assembled Monolayers: Applications in Materials Science
Kumar, A., Biebuyck, H. A., & Whitesides, G. M. (1994) · Langmuir · doi:10.1021/la00017a030 · Cited by 1,114
Self-citationSupercritical fluids as solvents for chemical and materials processing
Eckert, C. A., Knutson, B. L., & Debenedetti, P. G. (1996) · Nature · doi:10.1038/383313a0 · Cited by 923
Polymer microstructures formed by moulding in capillaries
Kim, E., Xia, Y., & Whitesides, G. M. (1995) · Nature · doi:10.1038/376581a0 · Cited by 878
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Complex Optical Surfaces Formed by Replica Molding Against Elastomeric Masters
Xia, Y., Kim, E., Zhao, X.-M., Rogers, J. A., Prentiss, M., & Whitesides, G. M. (1996) · Science · doi:10.1126/science.273.5273.347 · Cited by 643
Microfabrication by microcontact printing of self‐assembled monolayers
Wilbur, J. L., Kumar, A., Kim, E., & Whitesides, G. M. (1994) · Advanced Materials · doi:10.1002/adma.19940060719 · Cited by 463
Fabrication of Submicrometer Features on Curved Substrates by Microcontact Printing
Jackman, R. J., Wilbur, J. L., & Whitesides, G. M. (1995) · Science · doi:10.1126/science.7624795 · Cited by 434
Mechanism of Resist Pattern Collapse during Development Process
Tanaka, T., Mitsuaki Morigami, M. M., & Nobufumi Atoda, N. A. (1993) · Japanese Journal of Applied Physics · doi:10.1143/jjap.32.6059 · Cited by 353
Cited by
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Nanostructured Plasmonic Sensors
Stewart, M. E., Anderton, C. R., Thompson, L. B., Maria, J., Gray, S. K., Rogers, J. A., & Nuzzo, R. G. (2008) · Chemical Reviews · doi:10.1021/cr068126n · Cited by 2,415
Soft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334
New Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Metadata
- Authors
- Delamarche, E., Schmid, H., Michel, B., & Biebuyck, H.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 9
- Issue
- 9
- Pages
- 741-746
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2048368134
- Cited by
- 360
- References
- 10
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.