The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Materials, Designs, and Operational Characteristics for Fully Biodegradable Primary Batteries
Abstract
Biodegradable electronics represent an emerging class of technology with potential to provide advanced semiconductor functionality in temporary biomedical implants. This work reported a biodegradable primary battery as a potential power source for these systems, which uses biodegradable metal foils and polyanhydride packages. Monolithically integrating cells yields battery packs with sufficient power to operate conventional light emitting diodes and radio transmitters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Self-citationControl of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
(2011) · Wiley eBooks · doi:10.1002/9780470872864 · Cited by 1,514
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Self-citation(2010) · Cited by 909
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.029 · Cited by 558
Dissolvable Metals for Transient Electronics
Yin, L., Cheng, H., Mao, S., Haasch, R., Liu, Y., Xie, X., Hwang, S., Jain, H., Kang, S., Su, Y., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201301847 · Cited by 487
Self-citationBiocompatible and Biodegradable Materials for Organic Field‐Effect Transistors
Irimia‐Vladu, M., Troshin, P. A., Reisinger, M., Shmygleva, L., Kanbur, Y., Schwabegger, G., Bodea, M., Schwödiauer, R., Mumyatov, A., Fergus, J. W., et al. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201001031 · Cited by 444
Organic Thin‐Film Transistors Fabricated on Resorbable Biomaterial Substrates
Bettinger, C. J., & Bao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200902322 · Cited by 423
Transient, Biocompatible Electronics and Energy Harvesters Based on ZnO
Dagdeviren, C., Hwang, S., Su, Y., Kim, S., Cheng, H., Gur, O., Haney, R., Omenetto, F. G., Huang, Y., & Rogers, J. A. (2013) · Small · doi:10.1002/smll.201300146 · Cited by 412
Self-citation
Cited by
High-performance green flexible electronics based on biodegradable cellulose nanofibril paper
Jung, Y. H., Chang, T.-H., Zhang, H., Yao, C., Zheng, Q., Yang, V. W., Mi, H., Kim, M., Cho, S. J., Park, D.-W., et al. (2015) · Nature Communications · doi:10.1038/ncomms8170 · Cited by 891
Recent advances in wearable tactile sensors: Materials, sensing mechanisms, and device performance
Yang, T., Xie, D., Li, Z., & Zhu, H. (2017) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2017.02.001 · Cited by 750
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Challenges and opportunities for supercapacitors
Huang, S., Zhu, X., Sarkar, S., & Zhao, Y. (2019) · APL Materials · doi:10.1063/1.5116146 · Cited by 533
Instant tough bonding of hydrogels for soft machines and electronics
Wirthl, D., Pichler, R., Drack, M., Kettlguber, G., Moser, R., Gerstmayr, R., Hartmann, F., Bradt, E., Kaltseis, R., Siket, C. M., et al. (2017) · Science Advances · doi:10.1126/sciadv.1700053 · Cited by 471
The Evolution of Flexible Electronics: From Nature, Beyond Nature, and To Nature
Wang, P., Hu, M., Wang, H., Chen, Z., Feng, Y., Wang, J., Ling, W., & Huang, Y. (2020) · Advanced Science · doi:10.1002/advs.202001116 · Cited by 397
Transient Electronics: Materials and Devices
Fu, K. K., Wang, Z., Dai, J., Carter, M., & Hu, L. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b04931 · Cited by 371
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Design Considerations for Unconventional Electrochemical Energy Storage Architectures
Vlad, A., Singh, N., Galande, C., & Ajayan, P. M. (2015) · Advanced Energy Materials · doi:10.1002/aenm.201402115 · Cited by 346
Biodegradable Materials for Sustainable Health Monitoring Devices
Hosseini, E. S., Dervin, S., Ganguly, P., & Dahiya, R. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01139 · Cited by 326
Yang, Q., Huang, Z., Li, X., Liu, Z., Li, H., Liang, G., Wang, D., Huang, Q., Zhang, S., Chen, S., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b03650 · Cited by 309
Emerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Self-citationBiodegradable electronics: cornerstone for sustainable electronics and transient applications
Tan, M. J., Owh, C., Chee, P. L., Kyaw, A. K. K., Kai, D., & Loh, X. J. (2016) · Journal of Materials Chemistry C · doi:10.1039/c6tc00678g · Cited by 288
Becoming Sustainable, The New Frontier in Soft Robotics
Hartmann, F., Baumgartner, M., & Kaltenbrunner, M. (2021) · Advanced Materials · doi:10.1002/adma.202004413 · Cited by 281
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Li, R., Qi, H., Ma, Y., Deng, Y., Liu, S., Jie, Y., Jing, J., He, J., Zhang, X., Wheatley, L., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17008-8 · Cited by 272
Self-citationThe 2021 battery technology roadmap
Ma, J., Li, Y., Grundish, N. S., Goodenough, J. B., Chen, Y., Guo, L., Peng, Z., Qi, X., Yang, F., Qie, L., et al. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/abd353 · Cited by 269
Fully Biodegradable Microsupercapacitor for Power Storage in Transient Electronics
Lee, G., Kang, S., Won, S. M., Gutruf, P., Jeong, Y. R., Koo, J., Lee, S., Rogers, J. A., & Ha, J. S. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201700157 · Cited by 263
Self-citationPowering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Sheng, H., Zhou, J., Li, B., He, Y., Zhang, X., Liang, J., Zhou, J., Su, Q., Xie, E., Lan, W., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe3097 · Cited by 180
Metadata
- Authors
- Yin, L., Huang, X., Xu, H., Zhang, Y., Lam, J., Cheng, J., & Rogers, J. A.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2014-03-20
- Volume
- 26
- Issue
- 23
- Pages
- 3879-3884
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2122977422
- Cited by
- 336
- References
- 20
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.