A flexible and physically transient electrochemical sensor for real-time wireless nitric oxide monitoring
Open accessAbstract
Real-time sensing of nitric oxide (NO) in physiological environments is critically important in monitoring neurotransmission, inflammatory responses, cardiovascular systems, etc. Conventional approaches for NO detection relying on indirect colorimetric measurement or built with rigid and permanent materials cannot provide continuous monitoring and/or require additional surgical retrieval of the implants, which comes with increased risks and hospital cost. Herein, we report a flexible, biologically degradable and wirelessly operated electrochemical sensor for real-time NO detection with a low detection limit (3.97 nmol), a wide sensing range (0.01–100 μM), and desirable anti-interference characteristics. The device successfully captures NO evolution in cultured cells and organs, with results comparable to those obtained from the standard Griess assay. Incorporated with a wireless circuit, the sensor platform achieves continuous sensing of NO levels in living mammals for several days. The work may provide essential diagnostic and therapeutic information for health assessment, treatment optimization and postsurgical monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide synthases: regulation and function
Forstermann, U., & Sessa, W. C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr304 · Cited by 4,409
Nitric oxide and the immune response
Bogdan, C. (2001) · Nature Immunology · doi:10.1038/ni1001-907 · Cited by 3,447
Plasmonic photothermal therapy (PPTT) using gold nanoparticles
Huang, X., Jain, P. K., El-Sayed, I. H., & El-Sayed, M. A. (2008) · Lasers in Medical Science · doi:10.1007/s10103-007-0470-x · Cited by 2,376
Nutrition Board. Panel on Micronutrients (2001) · Medical Entomology and Zoology · Cited by 1,675
Particle size-dependent organ distribution of gold nanoparticles after intravenous administration
De Jong, W. H., Hagens, W. I., Krystek, P., Burger, M. C., Sips, A. J. A. M., & Geertsma, R. E. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.037 · Cited by 1,615
Nitric oxide in the central nervous system: neuroprotection versus neurotoxicity
Calabrese, V., Mancuso, C., Calvani, M., Rizzarelli, E., Butterfield, D. A., & Giuffrida Stella, A. M. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2214 · Cited by 1,543
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Self-citationBioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Nitric oxide signalling in cardiovascular health and disease
Farah, C., Michel, L. Y. M., & Balligand, J.-L. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.224 · Cited by 779
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Cited by
Lu, P., Ruan, D., Huang, M., Tian, M., Zhu, K., Gan, Z., & Xiao, Z. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01852-x · Cited by 667
Sheng, H., Zhou, J., Li, B., He, Y., Zhang, X., Liang, J., Zhou, J., Su, Q., Xie, E., Lan, W., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe3097 · Cited by 180
Design, printing, and engineering of regenerative biomaterials for personalized bone healthcare
Jia, Z., Xu, X., Zhu, D., & Zheng, Y. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101072 · Cited by 176
Chen, J., Chen, L., Fang, Y., Zeng, F., & Wu, S. (2022) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2021.100570 · Cited by 29
An Auto Adjustable Transimpedance Readout System for Wearable Healthcare Devices
Park, H., Lakshminarayana, S., Pan, C., Chung, H.-J., & Jung, S. (2022) · Electronics · doi:10.3390/electronics11081181 · Cited by 9
Metadata
- Authors
- Li, R., Qi, H., Ma, Y., Deng, Y., Liu, S., Jie, Y., Jing, J., He, J., Zhang, X., Wheatley, L., Huang, C., Sheng, X., Zhang, M., & Yin, L.
- Venue
- Nature Communications
- Published
- 2020-06-25
- Volume
- 11
- Issue
- 1
- Pages
- 3207-3207
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3037843633
- Cited by
- 272
- References
- 56
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A flexible and physically transient electrochemical sensor for real-time wireless nitric oxide monitoring. https://app.cochat.ai/papers/10.1038/s41467-020-17008-8
- The paper
- Li, R., Qi, H., Ma, Y., Deng, Y., Liu, S., Jie, Y., Jing, J., He, J., Zhang, X., Wheatley, L., Huang, C., Sheng, X., Zhang, M., & Yin, L. (2020). A flexible and physically transient electrochemical sensor for real-time wireless nitric oxide monitoring. Nature Communications. https://doi.org/10.1038/s41467-020-17008-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.