Cited by 672Innovative Energy Harvesting TechnologiesAdvanced Sensor and Energy Harvesting MaterialsFerroelectric and Piezoelectric Materials

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Self‐Powered Cardiac Pacemaker Enabled by Flexible Single Crystalline PMN‐PT Piezoelectric Energy Harvester

Open access

Abstract

A flexible single-crystalline PMN-PT piezoelectric energy harvester is demonstrated to achieve a self-powered artificial cardiac pacemaker. The energy-harvesting device generates a short-circuit current of 0.223 mA and an open-circuit voltage of 8.2 V, which are enough not only to meet the standard for charging commercial batteries but also for stimulating the heart without an external power source.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.201400562

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 40 references

Research works printed but not linked: 8

  1. Nelson G. D., 1993, Texas Heart Institute Journal, 20, 12
  2. Mallela V. S., 2004, Indian Pacing and Electrophysiology J., 4, 201
  3. Wang X. D., 2013, Am. Ceram. Soc. Bull, 92, 18
  4. Park K.‐I., 2014, Adv. Mater., 26, 2154
  5. Bedell S. W., 2013, J. Phys. D Appl. Phys., 46
  6. Chen L. P., 2011, Epl‐Europhys. Lett., 93
  7. Henderson I. R., 2006, Piezoelectric Ceramics: Principles and Applications
  8. Tian J., 2007, IEEE T. on, 54, 1895

Cited by

Sorted by citations

Items 201–300 of 672

Metadata

Authors
Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., Kwon, H., Lee, S., Joung, B., & Lee, K. J.
Affiliations
  • Korea Advanced Institute of Science and Technology (KR)
  • Yonsei University (KR)
  • Ibule Photonics (South Korea) (KR)
Corresponding author
Lee, Keon Jae
Venue
Advanced Materials
Publisher
Wiley
Published
2014-04-17
Volume
26
Issue
28
Pages
4880-4887
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W1968395095
Cited by
672
References
40
Citations by year
2026: 24 · 2025: 36 · 2024: 46 · 2023: 55 · 2022: 67 · 2021: 64 · 2020: 76 · 2019: 73 · 2018: 75 · 2017: 66 · 2016: 47 · 2015: 33 · 2014: 10
FWCI
60.54
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
  • YUHSpace (Yonsei University Medical Library) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
Keywords
PMN-PT single crystal, piezoelectric energy harvesting, flexible energy harvester, biomedical implants, cardiac pacing, battery charging, piezoelectric materials
MeSH terms
Crystallization, Energy Transfer, Equipment Design, Lead, Materials Testing, Niobium, Oxides, Pacemaker, Artificial, Electric Power Supplies, Titanium, Equipment Failure Analysis, Prostheses and Implants, Elastic Modulus, Micro-Electrical-Mechanical Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review