The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Flexible Organic/Inorganic Hybrid Near‐Infrared Photoplethysmogram Sensor for Cardiovascular Monitoring
Abstract
Wearable photoplethysmogram (PPG) sensors offer convenient and informative measurements for evaluating daily physiological states of individuals. In this work, epidermal and flexible near‐infrared (NIR) PPG sensors integrating a low‐power, high‐sensitivity organic phototransistor (OPT) with a high‐efficiency inorganic light‐emitting diode are developed. By exploiting an organic bulk heterojunction active layer and a bilayer gate dielectric design, a low voltage (<3 V) operated OPT with NIR responsivity as high as 3.5 × 10 5 A W−1 and noise equivalent power of 1.2 × 10−15 W Hz−1/2 is achieved, greatly surpassing commercial available silicon‐based photodetectors. In addition, the ultrathin encapsulation structure renders the device highly flexible and allows transfer printing of the device directly onto human skin. It is demonstrated that the epidermal/flexible PPG sensors are capable of continuously monitoring heart rate variability and precisely tracking the changes of pulse pressure at different postures of human subjects with the aid of electrocardiogram monitoring, exhibiting more reliable performance than commercial PPG sensors while consuming less power. The study suggests that the hybrid PPG sensor design may provide a promising solution for low‐power, real‐time physiological monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Rovere, M. T. L., Bigger, J. T., Marcus, F. I., Mortara, A., & Schwartz, P. J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11144-8 · Cited by 3,120
Hybrid graphene–quantum dot phototransistors with ultrahigh gain
Konstantatos, G., Badioli, M., Gaudreau, L., Osmond, J., Bernechea, M., de Arquer, F. P. G., Gatti, F., & Koppens, F. H. L. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.60 · Cited by 2,315
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Ultrasensitive solution-cast quantum dot photodetectors
Konstantatos, G., Howard, I., Fischer, A., Hoogland, S., Clifford, J., Klem, E., Levina, L., & Sargent, E. H. (2006) · Nature · doi:10.1038/nature04855 · Cited by 1,883
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Heart rate and cardiovascular mortality: The Framingham study
Kannel, W. B., Kannel, C., Paffenbarger, R. S., & Cupples, L. A. (1987) · American Heart Journal · doi:10.1016/0002-8703(87)90666-1 · Cited by 1,290
Blood Pressure as a Cardiovascular Risk Factor: Prevention and Treatment
Kannel, W. B. (1996) · JAMA · doi:10.1001/jama.1996.03530440051036 · Cited by 1,230
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Organic Photodetectors for Next‐Generation Wearable Electronics
Chow, P. C. Y., & Someya, T. (2020) · Advanced Materials · doi:10.1002/adma.201902045 · Cited by 779
Toward Flexible Surface‐Enhanced Raman Scattering (SERS) Sensors for Point‐of‐Care Diagnostics
Xu, K., Zhou, R., Takei, K., & Hong, M. (2019) · Advanced Science · doi:10.1002/advs.201900925 · Cited by 633
Multifunctional Skin‐Inspired Flexible Sensor Systems for Wearable Electronics
Xu, K., Lu, Y., & Takei, K. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800628 · Cited by 602
Ultrathin Air-Stable n-Type Organic Phototransistor Array for Conformal Optoelectronics
Liu, M., Wang, H., Tang, Q., Zhao, X., Tong, Y., & Liu, Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-35062-7 · Cited by 577
A High‐Performance Solution‐Processed Organic Photodetector for Near‐Infrared Sensing
Huang, J., Lee, J., Vollbrecht, J., Brus, V. V., Dixon, A. L., Cao, D. X., Zhu, Z., Du, Z., Wang, H., Cho, K., et al. (2020) · Advanced Materials · doi:10.1002/adma.201906027 · Cited by 492
Materials and Designs for Wearable Photodetectors
Cai, S., Xu, X., Yang, W., Chen, J., & Fang, X. (2019) · Advanced Materials · doi:10.1002/adma.201808138 · Cited by 445
Wang, C., Zhang, X., & Hu, W. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00431a · Cited by 428
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Wearable and flexible sensors for user-interactive health-monitoring devices
Ha, M., Lim, S., & Ko, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb01063c · Cited by 352
Exploration of Near-Infrared Organic Photodetectors
Li, Q., Guo, Y., & Liu, Y. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b00966 · Cited by 328
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Recent Progress on Broadband Organic Photodetectors and their Applications
Zhao, Z., Xu, C., Niu, L., Zhang, X., & Zhang, F. (2020) · Laser & Photonics Reviews · doi:10.1002/lpor.202000262 · Cited by 290
Ultraflexible Near‐Infrared Organic Photodetectors for Conformal Photoplethysmogram Sensors
Park, S., Fukuda, K., Wang, M., Lee, C., Yokota, T., Jin, H., Jinno, H., Kimura, H., Zalar, P., Matsuhisa, N., et al. (2018) · Advanced Materials · doi:10.1002/adma.201802359 · Cited by 275
Jinno, H., Yokota, T., Koizumi, M., Yukita, W., Saito, M., Osaka, I., Fukuda, K., & Someya, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22558-6 · Cited by 253
Homecare robotic systems for healthcare 4.0: visions and enabling technologies
Yang, G., Pang, Z., Jamal Deen, M., Dong, M., Zhang, Y.-T., Lovell, N., & Rahmani, A. M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2990529 · Cited by 213
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Xu, X., Zhang, X., Deng, W., Jie, J., & Zhang, X. (2018) · Small Methods · doi:10.1002/smtd.201700340 · Cited by 44
Metadata
- Authors
- Xu, H., Liu, J., Zhang, J., Zhou, G., Luo, N., & Zhao, N.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2017-06-14
- Volume
- 29
- Issue
- 31
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2625649160
- Cited by
- 298
- References
- 26
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.