Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

High‐Density Stretchable Electrode Grids for Chronic Neural Recording

Open access

Abstract

Electrical interfacing with neural tissue is key to advancing diagnosis and therapies for neurological disorders, as well as providing detailed information about neural signals. A challenge for creating long‐term stable interfaces between electronics and neural tissue is the huge mechanical mismatch between the systems. So far, materials and fabrication processes have restricted the development of soft electrode grids able to combine high performance, long‐term stability, and high electrode density, aspects all essential for neural interfacing. Here, this challenge is addressed by developing a soft, high‐density, stretchable electrode grid based on an inert, high‐performance composite material comprising gold‐coated titanium dioxide nanowires embedded in a silicone matrix. The developed grid can resolve high spatiotemporal neural signals from the surface of the cortex in freely moving rats with stable neural recording quality and preserved electrode signal coherence during 3 months of implantation. Due to its flexible and stretchable nature, it is possible to minimize the size of the craniotomy required for placement, further reducing the level of invasiveness. The material and device technology presented herein have potential for a wide range of emerging biomedical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201706520

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Stretchable Au-TiO2NW-PDMS composite. a) The TiO2NWs are coated with gold by reducing HAuCl4 salt with HDA in the presence of a capping agent (PVP). b) The addition of HCl stabilizes the dispersion and promotes a color change from brown–grey to orange–red. c–e) SEM images of the Au-TiO2NWs at different stages during the coating process. c) A partial gold coating is produced when 1/10 of the gold salt solution has been added. d) At the end of the reaction, a continuous gold coating has been produced. e) The initial gold coating is rough (left), but smoothens out after one week (right). f) The sheet resistance RS of films made from freshly produced Au-TiO2NWs improves over time (■). The conductivity of the NWs stored in the dispersion improves over time as well . g) Stretchable conductors are produced by embedding the NWs in PDMS. The sheet resistance remains below 10 Ω □−1 up to 100% strain. h) The conductors show excellent stability for 1000 strain cycles at 20%, 50%, and 100% strain. Scale bars: c,d) 500 nm, e) 200 nm.
Figure 1 Stretchable Au-TiO2NW-PDMS composite. a) The TiO2NWs are coated with gold by reducing HAuCl4 salt with HDA in the presence of a capping agent (PVP). b) The addition of HCl stabilizes the dispersion and promotes a color change from brown–grey to orange–red. c–e) SEM images of the Au-TiO2NWs at different stages during the coating process. c) A partial gold coating is produced when 1/10 of the gold salt solution has been added. d) At the end of the reaction, a continuous gold coating has been produced. e) The initial gold coating is rough (left), but smoothens out after one week (right). f) The sheet resistance RS of films made from freshly produced Au-TiO2NWs improves over time (■). The conductivity of the NWs stored in the dispersion improves over time as well . g) Stretchable conductors are produced by embedding the NWs in PDMS. The sheet resistance remains below 10 Ω □−1 up to 100% strain. h) The conductors show excellent stability for 1000 strain cycles at 20%, 50%, and 100% strain. Scale bars: c,d) 500 nm, e) 200 nm.CC BY-NC · PubMed Central
Figure 2 Soft and stretchable electrode grids. a) The electrode grid is made of Au-TiO2NW conductors embedded in PDMS and comprises 32 electrodes with 200 μm pitch. b) The stretchability allows the SEG to establish conformal contact around curved surfaces. c) An opening in the PDMS layer is etched to form the 50 μm large electrodes. A thin layer of platinum is electroplated onto the exposed Au-TiO2NWs to improve electrode performance. d) Optical surface profilometry reveals that the electrode openings are ≈7 μm deep. e) The SEM image of the electrode shows how the Pt-coated Au-TiO2NWs are partially embedded in the PDMS. f) The impedance of the electrode before (—) and after (—) electroplating of platinum. g) Measured impedance at 1 kHz of the electrodes of an SEG before (◆) and after Pt coating. h) Microscopy images of the electrode at 0% and 30% strain. i) The impedance of an electrode at 0% (—) and 30% (—) strain. Scale bars: a) 1 mm, b) 500 μm, c) 50 μm, e) 20 μm and 1 μm, h) 50 μm.
Figure 2 Soft and stretchable electrode grids. a) The electrode grid is made of Au-TiO2NW conductors embedded in PDMS and comprises 32 electrodes with 200 μm pitch. b) The stretchability allows the SEG to establish conformal contact around curved surfaces. c) An opening in the PDMS layer is etched to form the 50 μm large electrodes. A thin layer of platinum is electroplated onto the exposed Au-TiO2NWs to improve electrode performance. d) Optical surface profilometry reveals that the electrode openings are ≈7 μm deep. e) The SEM image of the electrode shows how the Pt-coated Au-TiO2NWs are partially embedded in the PDMS. f) The impedance of the electrode before (—) and after (—) electroplating of platinum. g) Measured impedance at 1 kHz of the electrodes of an SEG before (◆) and after Pt coating. h) Microscopy images of the electrode at 0% and 30% strain. i) The impedance of an electrode at 0% (—) and 30% (—) strain. Scale bars: a) 1 mm, b) 500 μm, c) 50 μm, e) 20 μm and 1 μm, h) 50 μm.CC BY-NC · PubMed Central
Figure 3 Implantation and in vivo neural recording of soft SEGs. a) Intraoperative microphotograph of soft SEG showing the probe in a craniotomy lying on the surface of the brain. Note the hydrophobic nature of the device demonstrated by a drop of water on the ribbon area. b) Zoomed-in microscopy image showing the ability of the probe to be inserted in smaller craniotomy than the probe geometry. c) Freely moving rat with chronically implanted SEG. d) Intraoperative recording of SSEPs using the soft SEG. Top: raw LFP time traces showing SSEPs generated by hind limb electrical stimulation. Right: heat map demonstrating the anatomical localization of SSEPs to the somatosensory cortex. Left: electric impedance of the SEGs at 1 kHz, showing a uniform impedance range across devices. Scale bars: a,b) 1 mm, c) 10 mm, d) 100 ms, 500 μV.
Figure 3 Implantation and in vivo neural recording of soft SEGs. a) Intraoperative microphotograph of soft SEG showing the probe in a craniotomy lying on the surface of the brain. Note the hydrophobic nature of the device demonstrated by a drop of water on the ribbon area. b) Zoomed-in microscopy image showing the ability of the probe to be inserted in smaller craniotomy than the probe geometry. c) Freely moving rat with chronically implanted SEG. d) Intraoperative recording of SSEPs using the soft SEG. Top: raw LFP time traces showing SSEPs generated by hind limb electrical stimulation. Right: heat map demonstrating the anatomical localization of SSEPs to the somatosensory cortex. Left: electric impedance of the SEGs at 1 kHz, showing a uniform impedance range across devices. Scale bars: a,b) 1 mm, c) 10 mm, d) 100 ms, 500 μV.CC BY-NC · PubMed Central
Figure 4 In vivo chronic recording and spatial distribution of local field potential. a) Time–frequency spectrogram of LFP recorded by the soft SEG during sleep in somatosensory cortex. The spectrogram during an NREM epoch contains slow oscillations (2–4 Hz) and sleep spindles (9–16 Hz); during a REM epoch theta (4–8 Hz) and gamma (30–80 Hz) oscillations were seen. Colors represent normalized power, with warmer colors indicating higher power. b) Raw LFP trace (top) and corresponding spectrogram (bottom) from 3 month chronically implanted SEG during an NREM epoch. c) Raw LFP trace highlighting a spatially patterned gamma oscillation during an NREM epoch. d) Average coherence between recording electrodes at each frequency band in an NREM session (— 2–4 Hz), (— 4–8 Hz), (— 9–16 Hz), (— 30–80 Hz). e) Mean power of recorded signal after 1 (—), 2 (—), and 3 (—) months of implantation. f) Number of functional recording electrodes after 1, 2, and 3 months of implantation, with high-quality recording electrodes in blue and low-quality recording electrodes in light blue. Scale bar: c) 100 ms.
Figure 4 In vivo chronic recording and spatial distribution of local field potential. a) Time–frequency spectrogram of LFP recorded by the soft SEG during sleep in somatosensory cortex. The spectrogram during an NREM epoch contains slow oscillations (2–4 Hz) and sleep spindles (9–16 Hz); during a REM epoch theta (4–8 Hz) and gamma (30–80 Hz) oscillations were seen. Colors represent normalized power, with warmer colors indicating higher power. b) Raw LFP trace (top) and corresponding spectrogram (bottom) from 3 month chronically implanted SEG during an NREM epoch. c) Raw LFP trace highlighting a spatially patterned gamma oscillation during an NREM epoch. d) Average coherence between recording electrodes at each frequency band in an NREM session (— 2–4 Hz), (— 4–8 Hz), (— 9–16 Hz), (— 30–80 Hz). e) Mean power of recorded signal after 1 (—), 2 (—), and 3 (—) months of implantation. f) Number of functional recording electrodes after 1, 2, and 3 months of implantation, with high-quality recording electrodes in blue and low-quality recording electrodes in light blue. Scale bar: c) 100 ms.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Research works printed but not linked: 2

  1. Lacour S. P., 2016, Nat. Rev. Mater., 1
  2. Linden H., 2011, Neuroendocrinology, 72, 859

Cited by

See all 306

Metadata

Authors
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J.
Affiliations
  • Linköping University (SE)
  • New York University (US)
  • ETH Zurich (CH)
Corresponding author
  • Tybrandt, Klas
  • Khodagholy, Dion
Venue
Advanced Materials
Publisher
Wiley
Published
2018-02-28
Volume
30
Issue
15
Pages
e1706520-e1706520
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2790457354
Cited by
286
References
38
Citations by year
2026: 14 · 2025: 32 · 2024: 38 · 2023: 50 · 2022: 38 · 2021: 46 · 2020: 31 · 2019: 29 · 2018: 8
FWCI
12.98
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
  • Europe PMC (PubMed Central) (acceptedVersion, cc-by-nc)
  • PubMed Central (acceptedVersion, cc-by-nc)
  • KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
  • Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by-nc)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
  • ETH Zürich Research Collection
  • Zurich Open Repository and Archive (University of Zurich)
Funders
  • Vetenskapsrådet (637‐2013‐7301)
  • Eidgenössische Technische Hochschule Zürich (UO1NS099705, U01NS090583)
  • Simons Foundation
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
stretchable electrodes, neural recording, silicone matrix, chronic implantation, cortical recording, mechanical mismatch, freely moving rats
MeSH terms
Animals, Electrodes, Rats, Nanowires

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐Density Stretchable Electrode Grids for Chronic Neural Recording. https://app.cochat.ai/papers/10.1002/adma.201706520
The paper
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018). High‐Density Stretchable Electrode Grids for Chronic Neural Recording. Advanced Materials. https://doi.org/10.1002/adma.201706520

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.