Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Corannulene‐Incorporated AIE Nanodots with Highly Suppressed Nonradiative Decay for Boosted Cancer Phototheranostics In Vivo

Gu, Xinggui, Zhang, Xiaoyan, Ma, Huili, Jia, Shaorui, Zhang, Pengfei, Zhao, Yanjun, Liu, Qian, Wang, Jianguo, Zheng, Xiaoyan, Lam, Jacky W. Y., Ding, Dan, Tang, Ben Zhong·2018·Advanced Materials

Abstract

Fluorescent nanoparticles (NPs) based on luminogens with aggregation‐induced emission characteristic (AIEgens), namely AIE dots, have received wide attention because of their antiquenching attitude in emission and reactive oxygen species (ROS) generation when aggregated. However, few reports are available on how to control and optimize their fluorescence and ROS generation ability. Herein, it is reported that enhancing the intraparticle confined microenvironment is an effective approach to advanced AIE dots, permitting boosted cancer phototheranostics in vivo. Formulation of a “rotor‐rich” and inherently charged near‐infrared (NIR) AIEgen with 1,2‐distearoyl‐sn‐glycero‐3‐phosphoethanolamine‐N‐[methoxy(polyethylene glycol)‐2000] and corannulene‐decorated PEG affords DSPE‐AIE dots and Cor‐AIE dots, respectively. Compared to DSPE‐AIE dots, Cor‐AIE dots show 4.0‐fold amplified fluorescence quantum yield and 5.4‐fold enhanced ROS production, because corannulene provides intraparticle rigidity and strong interactions with the AIEgen to restrict the intramolecular rotation of AIEgen to strongly suppress the nonradiative decay and significantly facilitate the fluorescence pathway and intersystem crossing. Thus, it tremendously promotes phototheranostic efficacies in terms of NIR image‐guided cancer surgery and photodynamic therapy using a peritoneal carcinomatosis‐bearing mouse model. Collectively, it not only provides a novel strategy to advanced AIE dots for cancer phototheranostics, but also brings new insights into the design of superior fluorescent NPs for biomedical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201801065

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 198

Metadata

Authors
Gu, X., Zhang, X., Ma, H., Jia, S., Zhang, P., Zhao, Y., Liu, Q., Wang, J., Zheng, X., Lam, J. W. Y., Ding, D., & Tang, B. Z.
Venue
Advanced Materials
Publisher
Wiley
Published
2018-05-16
Volume
30
Issue
26
Pages
e1801065-e1801065
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2804247992
Cited by
198
References
4
FWCI
10.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Corannulene‐Incorporated AIE Nanodots with Highly Suppressed Nonradiative Decay for Boosted Cancer Phototheranostics In Vivo. https://app.cochat.ai/papers/10.1002/adma.201801065
The paper
Gu, X., Zhang, X., Ma, H., Jia, S., Zhang, P., Zhao, Y., Liu, Q., Wang, J., Zheng, X., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2018). Corannulene‐Incorporated AIE Nanodots with Highly Suppressed Nonradiative Decay for Boosted Cancer Phototheranostics In Vivo. Advanced Materials. https://doi.org/10.1002/adma.201801065

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.