Near‐Infrared Tandem Organic Photodiodes for Future Application in Artificial Retinal Implants
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Photovoltaic retinal prostheses show great potential to restore sight in patients suffering from degenerative eye diseases by electrical stimulation of the surviving neurons in the retinal network. Herein, organic photodiodes (OPDs) sensitive to near‐infrared (NIR) light are evaluated as photovoltaic pixels for future application in retinal prostheses. Single‐junction and tandem OPDs are compared. In the latter, two nominally identical single‐junction cells are processed on top of each other, effectively doubling the open‐circuit voltage (V OC). Both single‐junction and tandem OPD micropixels can deliver the required charge to stimulate neurons under pulsed NIR light at physiologically safe intensities when connected to stimulating microelectrodes in a physiological saline solution. However, only tandem OPD pixels can cover the entire charge per pulse neural stimulation window due to their higher V OC (≈1.4 V). This demonstrates the viability of high‐resolution retinal prostheses based on flexible OPD arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Cited by
Exploration of Near-Infrared Organic Photodetectors
Li, Q., Guo, Y., & Liu, Y. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b00966 · Cited by 328
Near‐Infrared Materials: The Turning Point of Organic Photovoltaics
Meng, D., Zheng, R., Zhao, Y., Zhang, E., Dou, L., & Yang, Y. (2022) · Advanced Materials · doi:10.1002/adma.202107330 · Cited by 286
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
A conformable imager for biometric authentication and vital sign measurement
Yokota, T., Nakamura, T., Kato, H., Mochizuki, M., Tada, M., Uchida, M., Lee, S., Koizumi, M., Yukita, W., Takimoto, A., et al. (2020) · Nature Electronics · doi:10.1038/s41928-019-0354-7 · Cited by 227
Flexible Sensors—From Materials to Applications
Costa, J. C., Spina, F., Lugoda, P., Garcia-Garcia, L., Roggen, D., & Münzenrieder, N. (2019) · Technologies · doi:10.3390/technologies7020035 · Cited by 220
“Flexible substrates have been involved in the realisation of artificial retina implants thanks to their conformability to biological tissues [194,196].”
BackgroundMethodSelf‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Photovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63
Xu, Z., Wu, C., Zhu, Y., Ju, S., Ma, F., Guo, T., Li, F., & Kim, T. W. (2021) · Nanoscale · doi:10.1039/d0nr06550a · Cited by 26
Metadata
- Authors
- Simone, G., Di Carlo Rasi, D., de Vries, X., Heintges, G. H. L., Meskers, S. C. J., Janssen, R. A. J., & Gelinck, G. H.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-10-15
- Volume
- 30
- Issue
- 51
- Pages
- e1804678-e1804678
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2897811633
- Cited by
- 100
- References
- 5
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.