The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
High‐Resolution 3D NIR‐II Photoacoustic Imaging of Cerebral and Tumor Vasculatures Using Conjugated Polymer Nanoparticles as Contrast Agent
Abstract
Exogenous contrast‐agent‐assisted NIR‐II optical‐resolution photoacoustic microscopy imaging (ORPAMI) holds promise to decipher wide‐field 3D biological structures with deep penetration, large signal‐to‐background ratio (SBR), and high maximum imaging depth to depth resolution ratio. Herein, NIR‐II conjugated polymer nanoparticle (CP NP) assisted ORPAMI is reported for pinpointing cerebral and tumor vasculatures. The CP NPs exhibit a large extinction coefficient of 48.1 L g−1 at the absorption maximum of 1161 nm, with an ultrahigh PA sensitivity up to 2 µg mL−1. 3D ORPAMI of wide‐field mice ear allows clear visualization of regular vasculatures with a resolution of 19.2 µm and an SBR of 29.3 dB at the maximal imaging depth of 539 µm. The margin of ear tumor composed of torsional dense vessels among surrounding normal regular vessels can be clearly delineated via 3D angiography. In addition, 3D whole‐cortex cerebral vasculatures with large imaging area (48 mm 2), good resolution (25.4 µm), and high SBR (22.3 dB) at a depth up to 1001 µm are clearly resolved through the intact skull. These results are superior to the recently reported 3D NIR‐II fluorescence confocal vascular imaging, which opens up new opportunities for NIR‐II CP‐NP‐assisted ORPAMI in various biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A bright organic NIR-II nanofluorophore for three-dimensional imaging into biological tissues
Wan, H., Yue, J., Zhu, S., Uno, T., Zhang, X., Yang, Q., Yu, K., Hong, G., Wang, J., Li, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03505-4 · Cited by 450
Sheng, Z., Guo, B., Hu, D., Xu, S., Wu, W., Liew, W. H., Yao, K., Jiang, J., Liu, C., Zheng, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800766 · Cited by 445
Self-citationExploring the origin of high optical absorption in conjugated polymers
Vezie, M. S., Few, S., Meager, I., Pieridou, G., Dörling, B., Ashraf, R. S., Goñi, A. R., Bronstein, H., McCulloch, I., Hayes, S. C., et al. (2016) · Nature Materials · doi:10.1038/nmat4645 · Cited by 387
Cited by
Design of superior phototheranostic agents guided by Jablonski diagrams
Feng, G., Zhang, G.-Q., & Ding, D. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00671h · Cited by 783
Organic NIR-II molecule with long blood half-life for in vivo dynamic vascular imaging
Li, B., Zhao, M., Feng, L., Dou, C., Ding, S., Zhou, G., Lu, L., Zhang, H., Chen, F., Li, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16924-z · Cited by 374
The Chemistry of Organic Contrast Agents in the NIR‐II Window
Mu, J., Xiao, M., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202114722 · Cited by 305
Fluorination Enhances NIR‐II Fluorescence of Polymer Dots for Quantitative Brain Tumor Imaging
Liu, Y., Liu, J., Chen, D., Wang, X., Zhang, Z., Yang, Y., Jiang, L., Qi, W., Ye, Z., He, S., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202007886 · Cited by 173
Tan, J., Yin, K., Ouyang, Z., Wang, R., Pan, H., Wang, Z., Zhao, C., Guo, W., & Gu, X. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03926 · Cited by 52
Metadata
- Authors
- Guo, B., Chen, J., Chen, N., Middha, E., Xu, S., Pan, Y., Wu, M., Li, K., Liu, C., & Liu, B.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-05-07
- Volume
- 31
- Issue
- 25
- Pages
- e1808355-e1808355
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2944275891
- Cited by
- 159
- References
- 3
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.