The DOI matches its Crossref record; 171 of the 171 references it cites were found in a registry or an index.
The Chemistry of Organic Contrast Agents in the NIR‐II Window
Abstract
Optical imaging, especially fluorescence and photoacoustic imaging, is a non‐invasive imaging approach with high spatial and temporal resolution and high sensitivity, compared to positron emission tomography (PET) or magnetic resonance imaging (MRI). Due to the merits of imaging using the second near‐infrared (NIR‐II) window, like deeper penetration depth, high signal‐to‐noise ratio, high resolution, and low tissue damage, researchers have devoted great effort to developing contrast agents with NIR‐II absorption or emission. In this Review, we summarize recently developed organic luminescent and photoacoustic materials, ranging from small molecules to conjugated polymers. Then, we systematically introduce engineering strategies and describe the imaging performance classified by the skeleton cores. Finally, we elucidate the challenges and prospects of these NIR‐II organic dyes for potential clinical applications. We expect our summary can inspire researchers to expand the spectrum of NIR‐II contrast agents for diverse bioapplications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., Fuchs, H. E., & Jemal, A. (2021) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21654 · Cited by 16,522
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Semiconducting polymer nanoparticles as photoacoustic molecular imaging probes in living mice
Pu, K., Shuhendler, A. J., Jokerst, J. V., Mei, J., Gambhir, S. S., Bao, Z., & Rao, J. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.302 · Cited by 1,185
Molecular imaging in drug development
Willmann, J. K., van Bruggen, N., Dinkelborg, L. M., & Gambhir, S. S. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2290 · Cited by 1,171
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Cited by
NIR-II light in clinical oncology: opportunities and challenges
Zhang, Z., Du, Y., Shi, X., Wang, K., Qu, Q., Liang, Q., Ma, X., He, K., Chi, C., Tang, J., et al. (2024) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-024-00892-0 · Cited by 341
Song, S., Zhao, Y., Kang, M., Zhang, F., Wu, Q., Niu, N., Yang, H., Wen, H., Fu, S., Li, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202309748 · Cited by 147
Wang, L., Li, N., Wang, W., Mei, A., Shao, J., Wang, W., & Dong, X. (2024) · ACS Nano · doi:10.1021/acsnano.3c12316 · Cited by 127
Ma, D., Bian, H., Gu, M., Wang, L., Chen, X., & Peng, X. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.215677 · Cited by 124
Self-citationWan, Y., Chen, W., Liu, Y., Lee, K., Gao, Y., Zhang, D., Li, Y., Huang, Z., Luo, J., Lee, C., et al. (2024) · Advanced Materials · doi:10.1002/adma.202405966 · Cited by 90
Metadata
- Authors
- Mu, J., Xiao, M., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2022-02-03
- Volume
- 61
- Issue
- 14
- Pages
- e202114722-e202114722
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W4200233375
- Cited by
- 305
- References
- 171
- FWCI
- 14.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Chemistry of Organic Contrast Agents in the NIR‐II Window. https://app.cochat.ai/papers/10.1002/anie.202114722
- The paper
- Mu, J., Xiao, M., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X. (2022). The Chemistry of Organic Contrast Agents in the NIR‐II Window. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202114722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.