CoChat

The DOI matches its Crossref record; 151 of the 160 references it cites were found in a registry or an index.

The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective

Obidin, Nikita, Tasnim, Farita, Dagdeviren, Canan · 2020 · Advanced Materials

Abstract

The past two decades have seen unprecedented progress in the development of novel materials, form factors, and functionalities in neuroimplantable technologies, including electrocorticography (ECoG) systems, multielectrode arrays (MEAs), Stentrode, and deep brain probes. The key considerations for the development of such devices intended for acute implantation and chronic use, from the perspective of biocompatible hybrid materials incorporation, conformable device design, implantation procedures, and mechanical and biological risk factors, are highlighted. These topics are connected with the role that the U.S. Food and Drug Administration (FDA) plays in its regulation of neuroimplantable technologies based on the above parameters. Existing neuroimplantable devices and efforts to improve their materials and implantation protocols are first discussed in detail. The effects of device implantation with regards to biocompatibility and brain heterogeneity are then explored. Topics examined include brain‐specific risk factors, such as bacterial infection, tissue scarring, inflammation, and vasculature damage, as well as efforts to manage these dangers through emerging hybrid, bioelectronic device architectures. The current challenges of gaining clinical approval by the FDA—in particular, with regards to biological, mechanical, and materials risk factors—are summarized. The available regulatory pathways to accelerate next‐generation neuroimplantable devices to market are then discussed.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.201901482

Cites

151 of 151 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 160 references

Research works printed but not linked: 24

  1. Tenore F. V., 2011, Johns Hopkins APL Tech. Dig., 30, 230
  2. Krüger J., 2010, Front. Neuroeng., 3, 6
  3. Wise K., 1971, Solid‐State Circuits Conf. Digest of Technical Papers, 100
  4. Wang W., 2009, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, 586
  5. Potejanasak P., 2018, Fifth Int. Conf. on Industrial Engineering and Applications (ICIEA), 199
  6. Vetter R. J., 2005, Conf. Proc. IEEE Eng. Med. Biol. Soc., 7, 7341
  7. 10.1038/nmat3404 · DOI · Paper page
  8. Suzuki T., 2003, First Int. IEEE EMBS Conf. on Neural Engineering, 2003, 154
  9. Wu F., 2011, 16th Int. Solid‐State Sensors, Actuators and Microsystems Conf., 966
  10. Gilgunn P. J., 2012, 25th IEEE Int. Conf. on Micro Electro Mechanical Systems (MEMS), 56
  11. Barz F., 2015, 28th IEEE Int. Conf. on Micro Electro Mechanical Systems (MEMS), 636
  12. Schuhmann T. G., 2018, J. Visualized Exp., 137, E58003
  13. Strickland E., 2019, IEEE Spectrum
  14. Chamberlin S. L., 2005, Choice Rev. Online, 10, 42
  15. Escamilla‐Mackert T., 2009, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, 1616
  16. Wang A., 2005, American Institute of Chemical Engineering Annu. Meet.
  17. Tillman D.‐B., 2009, Letter to Patrick L. Johnson, Medtronic Neuromodulation
  18. Contreras‐Vidal J. L., 2014, FDA Public Workshop—Brain–Computer Interface (BCI) Devices for Patients with Paralysis and Amputation
  19. Voelker R., 2015, JAMA, J. Am. Med. Assoc., 314, 443
  20. Han M., 2008, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2008, 4220
  21. United States Food and Drug Administration, 2018, Agenda for Quarterly Meeting on MDUFA IV (FY 2018–2022) Performance
  22. Chan E., 2007, John M. Marshall J. Inf. Technol. Privacy Law, 25, 4
  23. Van Norman G. A., 2016, JACC, 1, 399
  24. Krucoff M. W., 2017, Harmonization by Doing (HBD) East 2017 Think Tank Meet.

Cited by

Items 101–126 of 126

Metadata

Authors
Obidin, N., Tasnim, F., & Dagdeviren, C.
Affiliations
  • MIT Media Lab (US)
  • MIT Media Lab Massachusetts Institute of Technology Cambridge MA 02139 USA
Venue
Advanced Materials
Publisher
Wiley
Published
2019-06-17
Volume
32
Issue
15
Pages
e1901482-e1901482
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2950959318
Cited by
126
References
160
Citations by year
2026: 6 · 2025: 27 · 2024: 21 · 2023: 21 · 2022: 14 · 2021: 21 · 2020: 15 · 2019: 1
FWCI
1.70
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
electrocorticography, microelectrode arrays, biocompatibility, hybrid materials, implantation procedure, device-related infection, neuroinflammation, bioelectronic devices, FDA regulation, regulatory pathways, chronic implantation
MeSH terms
Electrocorticography, Animals, Brain, Electrodes, Implanted, Humans, Risk Factors, Prostheses and Implants, Government Regulation, Wireless Technology, Optogenetics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.