The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
The DOI matches its Crossref record; 151 of the 160 references it cites were found in a registry or an index.
Abstract
The past two decades have seen unprecedented progress in the development of novel materials, form factors, and functionalities in neuroimplantable technologies, including electrocorticography (ECoG) systems, multielectrode arrays (MEAs), Stentrode, and deep brain probes. The key considerations for the development of such devices intended for acute implantation and chronic use, from the perspective of biocompatible hybrid materials incorporation, conformable device design, implantation procedures, and mechanical and biological risk factors, are highlighted. These topics are connected with the role that the U.S. Food and Drug Administration (FDA) plays in its regulation of neuroimplantable technologies based on the above parameters. Existing neuroimplantable devices and efforts to improve their materials and implantation protocols are first discussed in detail. The effects of device implantation with regards to biocompatibility and brain heterogeneity are then explored. Topics examined include brain‐specific risk factors, such as bacterial infection, tissue scarring, inflammation, and vasculature damage, as well as efforts to manage these dangers through emerging hybrid, bioelectronic device architectures. The current challenges of gaining clinical approval by the FDA—in particular, with regards to biological, mechanical, and materials risk factors—are summarized. The available regulatory pathways to accelerate next‐generation neuroimplantable devices to market are then discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Of the two, non-invasive sensors are more extensively researched and is generally preferred by many patients.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [292]
Citations
Cites
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861
Howard, D. M., Adams, M. J., Clarke, T.-K., Hafferty, J. D., Gibson, J., Shirali, M., Coleman, J. R. I., Hagenaars, S. P., Ward, J., Wigmore, E. M., et al. (2019) · Nature Neuroscience · doi:10.1038/s41593-018-0326-7 · Cited by 2,565
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Presurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669
Transfer printing by kinetic control of adhesion to an elastomeric stamp
Meitl, M. A., Zhu, Z.-T., Kumar, V., Lee, K. J., Feng, X., Huang, Y. Y., Adesida, I., Nuzzo, R. G., & Rogers, J. A. (2006) · Nature Materials · doi:10.1038/nmat1532 · Cited by 1,548
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Transfer Printing Techniques for Materials Assembly and Micro/Nanodevice Fabrication
Carlson, A., Bowen, A. M., Huang, Y., Nuzzo, R. G., & Rogers, J. A. (2012) · Advanced Materials · doi:10.1002/adma.201201386 · Cited by 917
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
The functional neuroanatomy of bipolar disorder: a review of neuroimaging findings
Strakowski, S. M., DelBello, M. P., & Adler, C. M. (2005) · Molecular Psychiatry · doi:10.1038/sj.mp.4001585 · Cited by 818
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Georges, P. C., Miller, W. J., Meaney, D. F., Sawyer, E. S., & Janmey, P. A. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.073114 · Cited by 724
Mechanical properties of gray and white matter brain tissue by indentation
Budday, S., Nay, R., de Rooij, R., Steinmann, P., Wyrobek, T., Ovaert, T. C., & Kuhl, E. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.02.024 · Cited by 692
Channelrhodopsin-2 and optical control of excitable cells
Zhang, F., Wang, L.-P., Boyden, E. S., & Deisseroth, K. (2006) · Nature Methods · doi:10.1038/nmeth936 · Cited by 689
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Jasper, H., & Penfield, W. (1949) · Archiv f�r Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01062488 · Cited by 682
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Macroporous Nanowire Nanoelectronic Scaffolds for Synthetic Tissues
Jia Liu, B., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., Lieber, C. M., & Tian, B. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 642
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Viscoelastic properties of individual glial cells and neurons in the CNS
Lu, Y.-B., Franze, K., Seifert, G., Steinhäuser, C., Kirchhoff, F., Wolburg, H., Guck, J., Janmey, P., Wei, E.-Q., Käs, J., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606150103 · Cited by 578
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Yu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Mechanical properties of brain tissue in-vivo: experiment and computer simulation
Miller, K., Chinzei, K., Orssengo, G., & Bednarz, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00120-2 · Cited by 501
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Fenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
Invasive recordings from the human brain: clinical insights and beyond
Engel, A. K., Moll, C. K. E., Fried, I., & Ojemann, G. A. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1585 · Cited by 419
Attenuation, scattering, and absorption of ultrasound in the skull bone
Pinton, G., Aubry, J.-F., Bossy, E., Muller, M., Pernot, M., & Tanter, M. (2011) · Medical Physics · doi:10.1118/1.3668316 · Cited by 405
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
Conducting Polymers for Neural Prosthetic and Neural Interface Applications
Green, R., & Abidian, M. R. (2015) · Advanced Materials · doi:10.1002/adma.201501810 · Cited by 392
Adrian, E. D. (1954) · BMJ · doi:10.1136/bmj.1.4857.287 · Cited by 381
Transfer printing techniques for flexible and stretchable inorganic electronics
Linghu, C., Zhang, S., Wang, C., & Song, J. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0037-x · Cited by 357
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Clinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
Hans Berger (1873-1941), Richard Caton (1842-1926), and electroencephalography
Haas, L. F. (2003) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.74.1.9 · Cited by 314
(2020) · ANSI/AAMI/ISO 10993-1:2018; Biological evaluation of medical devices—Part 1: Evaluation and testing within a risk management process · doi:10.2345/9781570207556.ch1 · Cited by 297
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Dynamic mechanical properties of human brain tissue
Fallenstein, G. T., Hulce, V. D., & Melvin, J. W. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90079-7 · Cited by 288
High‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Medical Device Recalls and the FDA Approval Process
Zuckerman, D. M., Brown, P., & Nissen, S. E. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.30 · Cited by 265
Predicting neurosurgical outcomes in focal epilepsy patients using computational modelling
Sinha, N., Dauwels, J., Kaiser, M., Cash, S. S., Brandon Westover, M., Wang, Y., & Taylor, P. N. (2017) · Brain · doi:10.1093/brain/aww299 · Cited by 254
Accelerated aging for testing polymeric biomaterials and medical devices
Hukins, D. W. L., Mahomed, A., & Kukureka, S. N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.001 · Cited by 247
Gardner, J. (2013) · Social Studies of Science · doi:10.1177/0306312713483678 · Cited by 243
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240
Toxicity evaluation of PEDOT/biomolecular composites intended for neural communication electrodes
Asplund, M., Thaning, E., Lundberg, J., Sandberg-Nordqvist, A. C., Kostyszyn, B., Inganäs, O., & von Holst, H. (2009) · Biomedical Materials · doi:10.1088/1748-6041/4/4/045009 · Cited by 227
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227
A history of optogenetics: the development of tools for controlling brain circuits with light
Boyden, E. S. (2011) · F1000 Biology Reports · doi:10.3410/b3-11 · Cited by 224
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 216
Somatic APP gene recombination in Alzheimer’s disease and normal neurons
Lee, M.-H., Siddoway, B., Kaeser, G. E., Segota, I., Rivera, R., Romanow, W. J., Liu, C. S., Park, C., Kennedy, G., Long, T., et al. (2018) · Nature · doi:10.1038/s41586-018-0718-6 · Cited by 210
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Medical Device Development: From Prototype to Regulatory Approval
Kaplan, A. V., Baim, D. S., Smith, J. J., Feigal, D. A., Simons, M., Jefferys, D., Fogarty, T. J., Kuntz, R. E., & Leon, M. B. (2004) · Circulation · doi:10.1161/01.cir.0000134695.65733.64 · Cited by 194
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
Kozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 190
NeuroMEMS: Neural Probe Microtechnologies
HajjHassan, M., Chodavarapu, V., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 190
Kourbeti, I. S., Vakis, A. F., Ziakas, P., Karabetsos, D., Potolidis, E., Christou, S., & Samonis, G. (2015) · Journal of Neurosurgery · doi:10.3171/2014.8.jns132557 · Cited by 187 · cited 1×
“A study by Kourbeti et al. (2015) found that the main infection-associated risk factors during the implantation process were meningitis (4.8% of cases) and gram negative bacteria such as Acinetobacter and Klebsiella spp. (44% of cases).”
BackgroundInfluentialSpencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-02107-2 · Cited by 181
Role of subdural electrocorticography in prediction of long-term seizure outcome in epilepsy surgery
Asano, E., Juhász, C., Shah, A., Sood, S., & Chugani, H. T. (2009) · Brain · doi:10.1093/brain/awp025 · Cited by 175
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
Corrosion of tungsten microelectrodes used in neural recording applications
Patrick, E., Orazem, M. E., Sanchez, J. C., & Nishida, T. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.012 · Cited by 167
Future of brain stimulation: New targets, new indications, new technology
Hariz, M. I., Blomstedt, P. C., & Zrinzo, L. U. (2013) · Movement Disorders · doi:10.1002/mds.25665 · Cited by 163
Wen, X., Wang, B., Huang, S., Liu, T. “., Lee, M.-S., Chung, P.-S., Chow, Y. T., Huang, I.-W., Monbouquette, H. G., Maidment, N. T., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.060 · Cited by 163
(2013) · Biological and Medical Physics, Biomedical Engineering · doi:10.1007/978-3-642-29746-5 · Cited by 162
Materials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Elektrobiologische Vorgänge an der menschlichen Hirnrinde
Foerster, O., & Altenburger, H. (1935) · Journal of Neurology · doi:10.1007/bf01732786 · Cited by 156
Djakovic-Svajcer, K. (2002) · Medicinski pregled · doi:10.2298/mpns0202005d · Cited by 155
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Bjerknes, S., Skogseid, I. M., Sæhle, T., Dietrichs, E., & Toft, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105288 · Cited by 145
Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wong, Y. T., Gerboni, G., Yoo, P. E., Lovell, T. J. H., Scordas, T. C. M., Wilson, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0321-z · Cited by 137
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Recent advances in neural dust: towards a neural interface platform
Neely, R., Piech, D. K., Santacruz, S. R., Maharbiz, M. M., & Carmena, J. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.12.010 · Cited by 134
Performance of conducting polymer electrodes for stimulating neuroprosthetics
Green, R. A., Matteucci, P. B., Hassarati, R. T., Giraud, B., Dodds, C. W. D., Chen, S., Byrnes-Preston, P. J., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016009 · Cited by 126
Deep Brain Stimulation: A Paradigm Shifting Approach to Treat Parkinson's Disease
Hickey, P., & Stacy, M. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00173 · Cited by 125
Kinetically controlled, adhesiveless transfer printing using microstructured stamps
Kim, T. H., Carlson, A., Ahn, J., Won, S. M., Wang, S., Huang, Y. Y., & Rogers, J. A. (2009) · Applied Physics Letters · doi:10.1063/1.3099052 · Cited by 114
Recent advances in silicon-based neural microelectrodes and microsystems: a review
Fekete, Z. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.055 · Cited by 111
Li, Z., Zhang, J., Yan, Y., & Li, X. (2016) · Stereotactic and Functional Neurosurgery · doi:10.1159/000449206 · Cited by 111
Mundinger, F. (2009) · Confinia Neurologica · doi:10.1159/000104030 · Cited by 110
Wafer-scale fabrication of penetrating neural microelectrode arrays
Bhandari, R., Negi, S., & Solzbacher, F. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9434-1 · Cited by 110
Lee, Y. K., Yu, K. J., Song, E., Barati Farimani, A., Vitale, F., Xie, Z., Yoon, Y., Kim, Y., Richardson, A., Luan, H., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b06697 · Cited by 109
Degenhart, A. D., Eles, J. R., Dum, R. P., Mischel, J., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler‐Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 108
Freire, M. A. M., Morya, E., Faber, J., dos Santos, J. R., Guimarães, J. S., Lemos, N. A. M., Sameshima, K., Pereira, A., Ribeiro, S. T. G., & Nicolelis, M. A. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027554 · Cited by 107
Miniaturized neural system for chronic, local intracerebral drug delivery
Dağdeviren, C., Ramadi, K. B., Joe, P., Spencer, K. C., Schwerdt, H. N., Shimazu, H., Delcasso, S., Amemori, K., Nunez-Lopez, C., Graybiel, A. M., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aan2742 · Cited by 107
Muir, J., Lopez, J., & Bagot, R. C. (2018) · Neuropsychopharmacology · doi:10.1038/s41386-018-0291-6 · Cited by 105
Penfield, W. G. (1936) · Archives of Neurology And Psychiatry · doi:10.1001/archneurpsyc.1936.02260090002001 · Cited by 104
Son, Y., Jenny Lee, H., Kim, J., Shin, H., Choi, N., Justin Lee, C., Yoon, E.-S., Yoon, E., Wise, K. D., Geun Kim, T., et al. (2015) · Scientific Reports · doi:10.1038/srep15466 · Cited by 101
A polymer-based neural microimplant for optogenetic applications: design and first in vivo study
Rubehn, B., Wolff, S. B. E., Tovote, P., Lüthi, A., & Stieglitz, T. (2013) · Lab on a Chip · doi:10.1039/c2lc40874k · Cited by 100
Implantation of Neural Probes in the Brain Elicits Oxidative Stress
Ereifej, E. S., Rial, G. M., Hermann, J. K., Smith, C. S., Meade, S. M., Rayyan, J., Chen, K., He, F., & Capadona, J. R. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00009 · Cited by 98
Microfluidic neural probes: in vivo tools for advancing neuroscience
Sim, J. Y., Haney, M. P., Park, S. I., McCall, J. G., & Jeong, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00103g · Cited by 92
Morishita, T., Hilliard, J. D., Okun, M. S., Neal, D., Nestor, K. A., Peace, D., Hozouri, A. A., Davidson, M. R., Bova, F. J., Sporrer, J. M., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0183711 · Cited by 86
The Ewing Amputation: The First Human Implementation of the Agonist-Antagonist Myoneural Interface
Clites, T. R., Herr, H., Srinivasan, S. S., Zorzos, A. N., & Carty, M. J. (2018) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000001997 · Cited by 85
Silk-Backed Structural Optimization of High-Density Flexible Intracortical Neural Probes
Wu, F., Tien, L. W., Chen, F., Berke, J. D., Kaplan, D. L., & Yoon, E. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2375326 · Cited by 80
Kristensen, B. W., Noraberg, J., Thiébaud, P., Koudelka‐Hep, M., & Zimmer, J. (2001) · Brain Research · doi:10.1016/s0006-8993(00)03304-7 · Cited by 76
Wu, F., Im, M., & Yoon, E. (2011) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2011.5969356 · Cited by 75
Parylene Coatings in Medical Devices and Implants: A Review
Kuppusami, S., & Oskouei, R. H. (2015) · Universal Journal of Biomedical Engineering · doi:10.13189/ujbe.2015.030201 · Cited by 74
Seven years of recording from monkey cortex with a chronically implanted multiple microelectrode
Krüger, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00006 · Cited by 73
A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes
Pas, J., Rutz, A. L., Quilichini, P., Slézia, A., Ghestem, A., Kaszás, A., Donahue, M. J., Curto, V. F., O'Connor, R. P., Bernard, C., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aadc1d · Cited by 72
Signal quality of simultaneously recorded endovascular, subdural and epidural signals are comparable
John, S. E., Opie, N. L., Wong, Y. T., Rind, G. S., Ronayne, S. M., Gerboni, G., Bauquier, S. H., O'Brien, T. J., May, C. N., Grayden, D. B., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26457-7 · Cited by 69
Panov, F. E., Levin, E. L., de Hemptinne, C., Swann, N. C., Qasim, S. E., Miocinovic, S., Ostrem, J. L., & Starr, P. A. (2016) · Journal of neurosurgery · doi:10.3171/2015.11.jns151341 · Cited by 66
A silicon carbide array for electrocorticography and peripheral nerve recording
Diaz-Botia, C. A., Luna, L. E., Neely, R., Chamanzar, M., Carraro, C., Carmena, J. M., Sabes, P. N., Maboudian, R., & Maharbiz, M. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7698 · Cited by 64
Shen, W., Karumbaiah, L., Liu, X., Saxena, T. K., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.10 · Cited by 62
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025010 · Cited by 61
Köhler, P., Wolff, A., Ejserholm, F., Wallman, L., Schouenborg, J., & Linsmeier, C. E. (2015) · PLoS ONE · doi:10.1371/journal.pone.0119340 · Cited by 56
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 56
Dynamic expression of genes associated with schizophrenia and bipolar disorder across development
Clifton, N. E., Hannon, E. J., Harwood, J. C., Florio, A. D., Thomas, K. L., Holmans, P., Walters, J., O’Donovan, M. C., Owen, M. J., Pocklington, A. J., et al. (2019) · Translational Psychiatry · doi:10.1038/s41398-019-0405-x · Cited by 56
Tseng, W.-T., Yen, C., & Tsai, M. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.08.028 · Cited by 54
Schwarz, E., Doan, N. T., Pergola, G., Westlye, L. T., Kaufmann, T., Wolfers, T., Brecheisen, R., Quarto, T., Ing, A., Carlo, P. D., et al. (2019) · Translational Psychiatry · doi:10.1038/s41398-018-0225-4 · Cited by 54
Awake craniotomy: A qualitative review and future challenges
Ghazanwy, M., Chakrabarti, R., Tewari, A., & Sinha, A. C. (2014) · Saudi Journal of Anaesthesia · doi:10.4103/1658-354x.140890 · Cited by 53
Near-Field Wireless Power Transfer to Stent-Based Biomedical Implants
Wiseman, G., Redoute, J.-M., Ganesan, K., Rind, G. S., John, S. E., Ronayne, S. M., Opie, N. L., Garrett, D. J., & Prawer, S. (2018) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2833386 · Cited by 49
Electrophysiological Mapping of Cat Primary Auditory Cortex with Multielectrode Arrays
Kim, S.-J., Manyam, S. C., Warren, D. J., & Normann, R. A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9037-9 · Cited by 45
DiLorenzo, D. J., Jankovic, J. J., Simpson, R. K., Takei, H., & Powell, S. Z.-E. (2014) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12192 · Cited by 44
Tissue-like Neural Probes for Understanding and Modulating the Brain
Hong, G., Viveros, R. D., Zwang, T. J., Yang, X., & Lieber, C. M. (2018) · Biochemistry · doi:10.1021/acs.biochem.8b00122 · Cited by 43
Flexible deep brain neural probe for localized stimulation and detection with metal guide
Kim, J. H., Lee, G. H., Kim, S., Chung, H. W., Lee, J. H., Lee, S. M., Kang, C. Y., & Lee, S. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.035 · Cited by 43
Vitale, F., Shen, W., Driscoll, N., Burrell, J. C., Richardson, A. G., Adewole, D. O., Murphy, B. B., Ananthakrishnan, A., Oh, H., Wang, T., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206137 · Cited by 43
Coles, J. A., Stewart-Hutchinson, P. J., Myburgh, E., & Brewer, J. M. (2017) · Methods · doi:10.1016/j.ymeth.2017.03.020 · Cited by 41
Intracerebral Infections as a Complication of Deep Brain Stimulation
Blomstedt, P. C., & Bjartmarz, H. (2012) · Stereotactic and Functional Neurosurgery · doi:10.1159/000335712 · Cited by 39
Matrigel coatings for P arylene sheath neural probes
Lee, C. D., Hara, S. A., Yu, L., Kuo, J. T. W., Kim, B., Hoang, T., Pikov, V., & Meng, E. F. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33390 · Cited by 37
Hess‐Dunning, A., & Tyler, D. J. (2018) · Micromachines · doi:10.3390/mi9110583 · Cited by 32
Shamir, R. R., Zaidel, A., Leo Joskowicz, B., Bergman, H., & Israel, Z. H. (2012) · Stereotactic and Functional Neurosurgery · doi:10.1159/000338252 · Cited by 31
Zhang, J., Wang, T., Zhang, C., Zeljic, K., Zhan, S., Sun, B., & Li, D. (2017) · Clinical Interventions in Aging · doi:10.2147/cia.s130882 · Cited by 30
The History and Horizons of Microscale Neural Interfaces
Kozai, T. D. Y. (2018) · Micromachines · doi:10.3390/mi9090445 · Cited by 30
Focal, remote-controlled, chronic chemical modulation of brain microstructures
Ramadi, K. B., Dağdeviren, C., Spencer, K. C., Joe, P., Cotler, M. J., Rousseau, E. B., Nunez-Lopez, C., Graybiel, A. M., Langer, R., & Cima, M. J. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1804372115 · Cited by 29
Easy-to-Prepare Assembly Array of Tungsten Microelectrodes
Takahashi, H., Suzurikawa, J., Nakao, M., Mase, F., & Kaga, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845224 · Cited by 27
Baumann, A. P., O'Neill, C., Owens, M. C., Weber, S. C., Sivan, S., D’Amico, R., Carmody, S., Bini, S. A., Sawyer, A., Lotz, J. C., et al. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24833 · Cited by 26 · cited 1×
“Adapted with permission.[118] Copyright 2018, M.”
Flexible deep brain neural probes based on a parylene tube structure
Zhao, Z., Kim, E. H., Luo, H., Zhang, J., & Xu, Y. P. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa9d61 · Cited by 25
Anderson, L., Antkowiak, P., Asefa, A., Ballard, A., Bansal, T., Bello, A., Berne, B. H., Bowsher, K. A., Blumenkopf, B., Broverman, I., et al. (2016) · Neuron · doi:10.1016/j.neuron.2016.10.036 · Cited by 21
Falconer, R. A., Rogers, S. L., & Shenai, M. B. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00544 · Cited by 20
Nanoscale tipped microwire arrays enhance electrical trap and depth injection of nanoparticles
Goryu, A., Numano, R., Ikedo, A., Ishida, M., & Kawano, T. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/41/415301 · Cited by 18
Some Aspects of Stimulation and Recording from the Basal Ganglia in Patients with Abnormal Movements
French, L. A., Story, J. L., Galicich, J. H., & Schultz, E. A. (2007) · Confinia Neurologica · doi:10.1159/000104370 · Cited by 17
Electroconductive polymer-coated silk fiber electrodes for neural recording and stimulation in vivo
Watanabe, S. P., Takahashi, H., & Torimitsu, K. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.037001 · Cited by 12
FDA Regulation of Invasive Neural Recording Electrodes: A Daunting Task for Medical Innovators
Welle, C. G., & Krauthamer, V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2181022 · Cited by 11
Badstübner-Meeske, K., Kröger, T., Mix, E., Gimsa, U., Benecke, R., & Gimsa, J. (2013) · Communications in computer and information science · doi:10.1007/978-3-642-38256-7_19 · Cited by 9
A.E.W. (1958) · Neurology · doi:10.1212/wnl.8.11.872-a · Cited by 8
Rothman, A., Davidson, S., Wiencek, R. G., Evans, W. N., Restrepo, H., Sarukhanov, V., Ruoslahti, E. I., Williams, R. M., & Mann, D. (2013) · Pulmonary Circulation · doi:10.4103/2045-8932.109913 · Cited by 7
Moon, T., Pellinen, D. S., Purcell, E. K., Seymour, J. P., & Kipke, D. R. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_896 · Cited by 3
Partially Hydrogenated Oils Are Out
Voelker, R. (2015) · JAMA · doi:10.1001/jama.2015.8387 · Cited by 3
Materials and Designs for Multimodal Flexible Neural Probes
Sunwoo, S. H., & Kim, T. (2016) · Microsystems and nanosystems · doi:10.1007/978-3-319-28694-5_15 · Cited by 3
Research works printed but not linked: 24
- Tenore F. V., 2011, Johns Hopkins APL Tech. Dig., 30, 230
- Krüger J., 2010, Front. Neuroeng., 3, 6
- Wise K., 1971, Solid‐State Circuits Conf. Digest of Technical Papers, 100
- Wang W., 2009, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, 586
- Potejanasak P., 2018, Fifth Int. Conf. on Industrial Engineering and Applications (ICIEA), 199
- Vetter R. J., 2005, Conf. Proc. IEEE Eng. Med. Biol. Soc., 7, 7341
- 10.1038/nmat3404 · DOI · Paper page
- Suzuki T., 2003, First Int. IEEE EMBS Conf. on Neural Engineering, 2003, 154
- Wu F., 2011, 16th Int. Solid‐State Sensors, Actuators and Microsystems Conf., 966
- Gilgunn P. J., 2012, 25th IEEE Int. Conf. on Micro Electro Mechanical Systems (MEMS), 56
- Barz F., 2015, 28th IEEE Int. Conf. on Micro Electro Mechanical Systems (MEMS), 636
- Schuhmann T. G., 2018, J. Visualized Exp., 137, E58003
- Strickland E., 2019, IEEE Spectrum
- Chamberlin S. L., 2005, Choice Rev. Online, 10, 42
- Escamilla‐Mackert T., 2009, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, 1616
- Wang A., 2005, American Institute of Chemical Engineering Annu. Meet.
- Tillman D.‐B., 2009, Letter to Patrick L. Johnson, Medtronic Neuromodulation
- Contreras‐Vidal J. L., 2014, FDA Public Workshop—Brain–Computer Interface (BCI) Devices for Patients with Paralysis and Amputation
- Voelker R., 2015, JAMA, J. Am. Med. Assoc., 314, 443
- Han M., 2008, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2008, 4220
- United States Food and Drug Administration, 2018, Agenda for Quarterly Meeting on MDUFA IV (FY 2018–2022) Performance
- Chan E., 2007, John M. Marshall J. Inf. Technol. Privacy Law, 25, 4
- Van Norman G. A., 2016, JACC, 1, 399
- Krucoff M. W., 2017, Harmonization by Doing (HBD) East 2017 Think Tank Meet.
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Soft Fiber Electronics Based on Semiconducting Polymer
Sun, F., Jiang, H., Wang, H., Zhong, Y., Xu, Y., Xing, Y., Yu, M., Feng, L.-W., Tang, Z., Liu, J., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00720 · Cited by 164
Metadata
- Authors
- Obidin, N., Tasnim, F., & Dagdeviren, C.
- Affiliations
- MIT Media Lab (US)
- MIT Media Lab Massachusetts Institute of Technology Cambridge MA 02139 USA
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-06-17
- Volume
- 32
- Issue
- 15
- Pages
- e1901482-e1901482
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2950959318
- Cited by
- 126
- References
- 160
- Citations by year
- 2026: 6 · 2025: 27 · 2024: 21 · 2023: 21 · 2022: 14 · 2021: 21 · 2020: 15 · 2019: 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- electrocorticography, microelectrode arrays, biocompatibility, hybrid materials, implantation procedure, device-related infection, neuroinflammation, bioelectronic devices, FDA regulation, regulatory pathways, chronic implantation
- MeSH terms
- Electrocorticography, Animals, Brain, Electrodes, Implanted, Humans, Risk Factors, Prostheses and Implants, Government Regulation, Wireless Technology, Optogenetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.