The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Macroporous nanowire nanoelectronic scaffolds for synthetic tissues
Open accessAbstract
The development of three-dimensional (3D) synthetic biomaterials as structural and bioactive scaffolds is central to fields ranging from cellular biophysics to regenerative medicine. As of yet, these scaffolds cannot electrically probe the physicochemical and biological micro-environments throughout their 3D and macroporous interior, although this capability could have a marked impact in both electronics and biomaterials. Here, we address this challenge using macroporous, flexible and free-standing nanowire nanoelectronic scaffolds (nanoES), and their hybrids with synthetic or natural biomaterials. 3D macroporous nanoES mimic the structure of natural tissue scaffolds, and they were formed by self-organization of coplanar reticular networks with built-in strain and by manipulation of 2D mesh matrices. NanoES exhibited robust electronic properties and have been used alone or combined with other biomaterials as biocompatible extracellular scaffolds for 3D culture of neurons, cardiomyocytes and smooth muscle cells. Additionally, we show the integrated sensory capability of the nanoES by real-time monitoring of (i) the local electrical activity within 3D nanoES/cardiomyocyte constructs, (ii) the response of 3D nanoES based neural and cardiac tissue models to drugs, and (iii) distinct pH changes inside and outside tubular vascular smooth muscle constructs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [313]
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“The bottom PLGA layer was made either by inserting an existing layer underneath the mesh-like scaffold or by directly electrospinning on the nanoES.”
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Ultralight Metallic Microlattices
Schaedler, T. A., Jacobsen, A. J., Torrents, A., Sorensen, A. E., Lian, J., Greer, J. R., Valdevit, L., & Carter, W. B. (2011) · Science · doi:10.1126/science.1211649 · Cited by 1,784 · cited 2×
“c, SEM image of a single-kinked-nanowire FET within a reticular scaffold, showing (1) the kinked nanowire, (2) metallic interconnects (dashed magenta lines) and (3) the SU-8 backbone.”
Photodegradable Hydrogels for Dynamic Tuning of Physical and Chemical Properties
Kloxin, A. M., Kasko, A. M., Salinas, C. N., & Anseth, K. S. (2009) · Science · doi:10.1126/science.1169494 · Cited by 1,748 · cited 1×
“(5) The silicon substrate was then coated with MMA and PMMA double layer resist, the resist was patterned over the chosen SU-8 ribbons, and then nonsymmetrical Cr/ Pd/Cr (1.”
Interfering with pH regulation in tumours as a therapeutic strategy
Neri, D., & Supuran, C. T. (2011) · Nature Reviews Drug Discovery · doi:10.1038/nrd3554 · Cited by 1,547
Nanoelectronics from the bottom up
Lu, W., & Lieber, C. M. (2007) · Nature Materials · doi:10.1038/nmat2028 · Cited by 1,545
Self-citationA completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Self-citationA Rubberlike Stretchable Active Matrix Using Elastic Conductors
Sekitani, T., Noguchi, Y., Hata, K., Fukushima, T., Aida, T., & Someya, T. (2008) · Science · doi:10.1126/science.1160309 · Cited by 1,366
Research works printed but not linked: 1
- Zipes, D. P. & Jalife, J. Cardiac Electrophysiology: From Cell to Bedside 5th edn (Saunders, 2009).
Cited by
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Fractal design concepts for stretchable electronics
Fan, J. A., Yeo, W.-H., Su, Y., Hattori, Y., Lee, W., Jung, S.-Y., Zhang, Y., Liu, Z., Cheng, H., Falgout, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms4266 · Cited by 1,088
“square, (2) thick mesh, (3) thin mesh, (4) horizontal and vertical stripes separated by a spacer, (5) Peano curve, (6) Hilbert curve, (7) Serpentine Greek”
BackgroundFunctional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Self-citation3D biofabrication strategies for tissue engineering and regenerative medicine
Bajaj, P., Schweller, R. M., Khademhosseini, A., West, J. L., & Bashir, R. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105155 · Cited by 632
“8-mm separation in a nanoES/cardiac construct (168).”
Background
Metadata
- Authors
- Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Kohane, Daniel S.
- Lieber, Charles M.
- ORCID
- Venue
- Nature Materials
- Published
- 2012-08-26
- Volume
- 11
- Issue
- 11
- Pages
- 986-994
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- PMC
- PMC3623694
- OpenAlex
- W1566118744
- Semantic Scholar
- a2e3dd875e3921aac870aa425019584caf823e20
- Cited by
- 20
- References
- 43
- Citations by year
- 2025: 2 · 2023: 6 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 3 · 2014: 2 · 2013: 2
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion)
- PMC
- Funders
- National Institutes of Health (5r01de016516-10, DP1OD003900)
- National Institute of General Medical Sciences (GM073626, R01GM073626)
- National Institute of Dental and Craniofacial Research (DE016516, R01-DE016516, DE013023, R01DE013023)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Keywords
- macroporous scaffolds, 3D biomaterials, vascular smooth muscle, drug response, pH sensing, regenerative medicine
- MeSH terms
- Biocompatible Materials, Humans, Muscle, Smooth, Vascular, Silicon, Transistors, Electronic, Porosity, Tissue Engineering, Nanotechnology, Nanowires, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Macroporous nanowire nanoelectronic scaffolds for synthetic tissues. https://app.cochat.ai/papers/10.1038/nmat3404
- The paper
- Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M. (2012). Macroporous nanowire nanoelectronic scaffolds for synthetic tissues. Nature Materials. https://doi.org/10.1038/nmat3404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.