CoChat

Cutaneous Ionogel Mechanoreceptors for Soft Machines, Physiological Sensing, and Amputee Prostheses

Shen, Zequn, Zhu, Xiangyang, Majidi, Carmel, Gu, Guoying · 2021 · Advanced Materials

The DOI matches its Crossref record; 47 of the 48 references it cites were found in a registry or an index.

Abstract

Touch sensing has a central role in robotic grasping and emerging human–machine interfaces for robot‐assisted prosthetics. Although advancements in soft conductive polymers have promoted the creation of diverse pressure sensors, these sensors are difficult to be employed as touch skins for robotics and prostheses due to their limited sensitivity, narrow pressure range, and complex structure and fabrication process. Here, a highly sensitive and robust soft touch skin is presented with ultracapacitive sensing that combines ionic hydrogels with commercially available conductive fabrics. Prototypical designs of the capacitive sensors through facile manufacturing methods are introduced and a high sensitivity up to 1.5 kPa −1 (≈44 times higher than conventional parallel‐plate capacitive counterparts), a broad pressure detection range of over four orders of magnitudes (≈35 Pa to 330 kPa), ultrahigh baseline of capacitance, fast response time (≈18 ms), and good repeatability are demonstrated. Ionogel skins composed of an array of cutaneous mechanoreceptors capable of monitoring various physiological signals and shape detection are further developed. The touch skin can be integrated within a soft bionic hand and provide an industrial robot and an amputee with robust tactile feedback when handling delicate objects, illustrating its potential applications in next‐generation human‐in‐the‐loop robotic systems with tactile sensing.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.202102069

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Gu G., 2021, Nat. Biomed. Eng.

Cited by

See all 291

Metadata

Authors
Shen, Z., Zhu, X., Majidi, C., & Gu, G.
Affiliations
  • Shanghai Jiao Tong University (CN)
  • Carnegie Mellon University (US)
Corresponding author
  • Majidi, Carmel
  • Gu, Guoying
Venue
Advanced Materials
Publisher
Wiley
Published
2021-08
Volume
33
Issue
38
Pages
e2102069-e2102069
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3192827693
Cited by
291
References
48
Citations by year
2026: 39 · 2025: 58 · 2024: 66 · 2023: 68 · 2022: 55 · 2021: 5
FWCI
14.74
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (52025057, 91948302)
  • Science and Technology Commission of Shanghai Municipality (20550712100)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Dielectric materials and actuators
Keywords
ionogels, mechanoreceptors, tactile sensing, capacitive pressure sensor, ionic hydrogels, conductive textiles, soft robotics, bionic hand, tactile feedback, physiological sensing, shape detection, human-machine interaction
MeSH terms
Wearable Electronic Devices, Amputees, Artificial Limbs, Humans, Mechanoreceptors, Prosthesis Design, Robotics, Skin, Touch, Hydrogels, Electric Capacitance, Touch Perception

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.