CoChat

Hybrid Metamaterial Absorber Platform for Sensing of CO 2 Gas at Mid‐IR

Open access
Hasan, Dihan, Lee, Chengkuo · 2018 · Advanced Science

The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.

Abstract

Application of two major classes of CO 2 gas sensors, i.e., electrochemical and nondispersive infrared is predominantly impeded by the poor selectivity and large optical interaction length, respectively. Here, a novel “ hybrid metamaterial ” absorber platform is presented by integrating the state‐of‐the‐art complementary metal–oxide–semiconductor compatible metamaterial with a smart, gas‐selective‐trapping polymer for highly selective and miniaturized optical sensing of CO 2 gas in the 5–8 µm mid‐IR spectral window. The sensor offers a minimum of 40 ppm detection limit at ambient temperature on a small footprint (20 µm by 20 µm), fast response time (≈2 min), and low hysteresis. As a proof‐of‐concept, net absorption enhancement of 0.0282%/ppm and wavelength shift of 0.5319 nm ppm −1 are reported. Furthermore, the gas‐ selective smart polymer is found to enable dual‐mode multiplexed sensing for crosschecking and validation of gas concentration on a single platform. Additionally, unique sensing characteristics as determined by the operating wavelength and bandwidth are demonstrated. Also, large differential response of the metamaterial absorber platform for all‐optical monitoring is explored. The results will pave the way for a physical understanding of metamaterial‐based sensing when integrated with the mid‐IR detector for readout and extending the mid‐IR functionalities of selective polymers for the detection of technologically relevant gases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.201700581

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 a) Increasing emission of CO2 as one of the emerging environmental risk factors for living beings demanding large‐scale deployment of sensors achievable only under low cost, CMOS platform. b) Conceptual diagram of state‐of‐the‐art nondispersive infrared (NDIR) sensing platform. “Active metamaterial” absorber platform with the potential for physically trapping CO2 gas and thereby, reducing the gas cell length for miniaturized sensor is indicated accordingly. c) Proposed “hybrid metamaterial” absorber integrated with thin film membrane for selective gas sensing. d) FESEM (field emission scanning electron microscopy) image of the array of the metamaterial patterns (Inset: zoomed in view of the unit cell). e) AFM image of the PEI surface coated on the metamaterial patterns. f) AFM height profile of the PEI surface. g) Crosswire metamaterial pattern for polarization independent sensing characteristics h). i) 3D FDTD (finite‐difference time‐domain) simulated electric field and magnetic field intensity distribution along XY plane and XZ plane of the absorber device, respectively, at the perfect absorber resonant condition. Confinement of H‐field in the dielectric spacer region leading to antiparallel current flow between the top metal and bottom metal at absorption resonance is marked by the white rectangular boundary. j) Coupling of metamaterial absorption resonance mediated by thin film interference into the vibrational modes of CO2 selective layer for the sensing (adsorption and desorption) k). l) Energy diagram representation and effect of coupling to closely spaced material vibrations on metamaterial resonance, respectively. Presence of infrared material vibrations is strongly subject to gas adsorption and desorption providing multiple routes for the selective detection of CO2 gas.
Figure 1 a) Increasing emission of CO2 as one of the emerging environmental risk factors for living beings demanding large‐scale deployment of sensors achievable only under low cost, CMOS platform. b) Conceptual diagram of state‐of‐the‐art nondispersive infrared (NDIR) sensing platform. “Active metamaterial” absorber platform with the potential for physically trapping CO2 gas and thereby, reducing the gas cell length for miniaturized sensor is indicated accordingly. c) Proposed “hybrid metamaterial” absorber integrated with thin film membrane for selective gas sensing. d) FESEM (field emission scanning electron microscopy) image of the array of the metamaterial patterns (Inset: zoomed in view of the unit cell). e) AFM image of the PEI surface coated on the metamaterial patterns. f) AFM height profile of the PEI surface. g) Crosswire metamaterial pattern for polarization independent sensing characteristics h). i) 3D FDTD (finite‐difference time‐domain) simulated electric field and magnetic field intensity distribution along XY plane and XZ plane of the absorber device, respectively, at the perfect absorber resonant condition. Confinement of H‐field in the dielectric spacer region leading to antiparallel current flow between the top metal and bottom metal at absorption resonance is marked by the white rectangular boundary. j) Coupling of metamaterial absorption resonance mediated by thin film interference into the vibrational modes of CO2 selective layer for the sensing (adsorption and desorption) k). l) Energy diagram representation and effect of coupling to closely spaced material vibrations on metamaterial resonance, respectively. Presence of infrared material vibrations is strongly subject to gas adsorption and desorption providing multiple routes for the selective detection of CO2 gas.CC BY · PubMed Central
Figure 2 a) Chemical reactions followed by the adsorption and desorption of the CO2 sensitive layer and frequency assignments for the possible byproducts of the reaction path. Upon heating in a nitrogen environment, the formed species can recover back to original polyetheleneimine with negligible loss. b) Schematic of the gas sensing setup and c) gas sensing setup used for the experiment. The volume of the gas chamber used is 100 cm3. Gas flow rate is maintained at 500 mL min−1 with N2 used as the carrier gas. d) Comparison between as prepared (exposed to 600 ppm CO2 in ambient) and thermally desorped (treated at 100 °C for 2 min) PEI film. e) Effects of as prepared and thermally desorped PEI film on the resonance profile of the crosswire absorber structure. Five distinct frequency points are identified (pt1: 6.06 µm, pt2: 6.57 µm, pt3: 6.75 µm, pt4: 7.092 µm, and pt5: 7.57 µm) for studying the gas sensing characteristics of the hybrid geometry. f) Response of the metamaterial absorber structure in the absence of gas‐selective layer as exposed to various CO2 concentrations at 70% ambient humidity.
Figure 2 a) Chemical reactions followed by the adsorption and desorption of the CO2 sensitive layer and frequency assignments for the possible byproducts of the reaction path. Upon heating in a nitrogen environment, the formed species can recover back to original polyetheleneimine with negligible loss. b) Schematic of the gas sensing setup and c) gas sensing setup used for the experiment. The volume of the gas chamber used is 100 cm3. Gas flow rate is maintained at 500 mL min−1 with N2 used as the carrier gas. d) Comparison between as prepared (exposed to 600 ppm CO2 in ambient) and thermally desorped (treated at 100 °C for 2 min) PEI film. e) Effects of as prepared and thermally desorped PEI film on the resonance profile of the crosswire absorber structure. Five distinct frequency points are identified (pt1: 6.06 µm, pt2: 6.57 µm, pt3: 6.75 µm, pt4: 7.092 µm, and pt5: 7.57 µm) for studying the gas sensing characteristics of the hybrid geometry. f) Response of the metamaterial absorber structure in the absence of gas‐selective layer as exposed to various CO2 concentrations at 70% ambient humidity.CC BY · PubMed Central
Figure 3 Thickness versus wavelength map of the reflection spectrum of the polymer‐metal geometry. a) Oscillator strength εlorentz fixed at 0.0005. b) Oscillator strength εlorentz fixed at 0.0025. c) Length dependence of the reflection spectra of the metamaterial patterns (C1–C10) coated with 300 nm PEI film (as prepared, i.e., exposed to ambient CO2) when the back metal reflector is removed. d) Reflection spectra of the similar C1 structure coated with 300 nm PEI film at two different states: (i) as prepared (ii) thermally desorped showing no strong coupling with the background resonance of the pattern.
Figure 3 Thickness versus wavelength map of the reflection spectrum of the polymer‐metal geometry. a) Oscillator strength εlorentz fixed at 0.0005. b) Oscillator strength εlorentz fixed at 0.0025. c) Length dependence of the reflection spectra of the metamaterial patterns (C1–C10) coated with 300 nm PEI film (as prepared, i.e., exposed to ambient CO2) when the back metal reflector is removed. d) Reflection spectra of the similar C1 structure coated with 300 nm PEI film at two different states: (i) as prepared (ii) thermally desorped showing no strong coupling with the background resonance of the pattern.CC BY · PubMed Central
Figure 4 Geometry‐dependent gas sensing characteristics of the hybrid absorber structures a–j) C1–C10 geometry, respectively. The dashed arrow line locates the spectral position of CO2 molecule trapped inside the PEI overlayer. The gray region indicates the spectral position of the metamaterial absorption resonance in the background. Clearly, a significant spectral broadening is observed (e.g., C9) as the absorption resonance overlaps with the densely positioned vibrational modes of the gas sensitive layer. Also, the broadening increases as the gas concentration increases. Obvious redshift is observed as well (C1) as the gas concentration increases.
Figure 4 Geometry‐dependent gas sensing characteristics of the hybrid absorber structures a–j) C1–C10 geometry, respectively. The dashed arrow line locates the spectral position of CO2 molecule trapped inside the PEI overlayer. The gray region indicates the spectral position of the metamaterial absorption resonance in the background. Clearly, a significant spectral broadening is observed (e.g., C9) as the absorption resonance overlaps with the densely positioned vibrational modes of the gas sensitive layer. Also, the broadening increases as the gas concentration increases. Obvious redshift is observed as well (C1) as the gas concentration increases.CC BY · PubMed Central
Figure 5 Geometry dependence of on–off switching observed in the differential spectra of the perfect absorber structures as a function of gas concentration a–j) C1–C10 geometry, respectively. The gray region indicates the spectral location of the metamaterial absorption resonance in each case. The peak switching contrast is observed to be in C5 geometry (≈9.85) as an outcome of the perfect impedance matching obtained in the hybrid geometry for a given thickness of the gas‐selective layer (≈300 nm). A pronounced splitting of the switching peak is observed (C6 and C7) that results from the interplay between the coupling of closely spaced vibrational modes and the background metamaterial absorption resonance. In all cases, the switching contrast scales up with the increased gas concentration.
Figure 5 Geometry dependence of on–off switching observed in the differential spectra of the perfect absorber structures as a function of gas concentration a–j) C1–C10 geometry, respectively. The gray region indicates the spectral location of the metamaterial absorption resonance in each case. The peak switching contrast is observed to be in C5 geometry (≈9.85) as an outcome of the perfect impedance matching obtained in the hybrid geometry for a given thickness of the gas‐selective layer (≈300 nm). A pronounced splitting of the switching peak is observed (C6 and C7) that results from the interplay between the coupling of closely spaced vibrational modes and the background metamaterial absorption resonance. In all cases, the switching contrast scales up with the increased gas concentration.CC BY · PubMed Central
Figure 6 Demonstration of multiplexed sensing on the proposed platform at steady state condition a) design of super cell composed of unit cell I and unit cell II for multiplexed sensor b). Simulated resonance profile of the supercell geometry overlaid by the gas‐selective layer. Polarization of the incoming radiation is fixed along y‐axis c). d) Electric field (at XY plane) and magnetic field (at XZ plane) distribution, respectively, when unit cell I is resonant at 5.25 µm e). f) Electric field (at xy plane) and magnetic field (at xz plane) distribution, respectively, when unit cell II is resonant at 6.75 µm. g) Steady‐state sensing characteristics of the multiplexed platform. Inset: fabricated superpixel.
Figure 6 Demonstration of multiplexed sensing on the proposed platform at steady state condition a) design of super cell composed of unit cell I and unit cell II for multiplexed sensor b). Simulated resonance profile of the supercell geometry overlaid by the gas‐selective layer. Polarization of the incoming radiation is fixed along y‐axis c). d) Electric field (at XY plane) and magnetic field (at XZ plane) distribution, respectively, when unit cell I is resonant at 5.25 µm e). f) Electric field (at xy plane) and magnetic field (at xz plane) distribution, respectively, when unit cell II is resonant at 6.75 µm. g) Steady‐state sensing characteristics of the multiplexed platform. Inset: fabricated superpixel.CC BY · PubMed Central
Figure 7 a) Dynamic behavior of average absorption in C9 geometry obtained by integrating the normalized absorption within the spectral window: 5–8 µm. b) Differential absorption at steady state fitted under 2 parameter exponential model ( f(x) = a*exp(b*x) + c*exp(d*x)) indicating saturation behavior of the sensor as the gas concentration increases in continuous mode. The fitting values of a, b, c, and d are 0.04555, 0.0004665, −0.04551, and −0.0691, respectively, with R‐square value of 0.9993.
Figure 7 a) Dynamic behavior of average absorption in C9 geometry obtained by integrating the normalized absorption within the spectral window: 5–8 µm. b) Differential absorption at steady state fitted under 2 parameter exponential model ( f(x) = a*exp(b*x) + c*exp(d*x)) indicating saturation behavior of the sensor as the gas concentration increases in continuous mode. The fitting values of a, b, c, and d are 0.04555, 0.0004665, −0.04551, and −0.0691, respectively, with R‐square value of 0.9993.CC BY · PubMed Central
Figure 8 a) Steady‐state normalized reflection of C9 absorber structure at different concentrations. b) Time evolution of normalized reflection at two distinct spectral regions: pt2 and pt4 as the concentration increases in continuous mode. c) Extracted steady state normalized reflection. d–h) Time‐dependent average absorption as a function of gas concentration integrated over a bandwidth of 400 nm around pt1, pt2, pt3, pt4, and pt5 spectral position, respectively. Increasing trend is observed for pt1, pt2, and pt5 whereas decreasing trend is observed for pt4. Average absorption is found to reach a maximum at intermediate concentration (80 ppm) at pt3 location.
Figure 8 a) Steady‐state normalized reflection of C9 absorber structure at different concentrations. b) Time evolution of normalized reflection at two distinct spectral regions: pt2 and pt4 as the concentration increases in continuous mode. c) Extracted steady state normalized reflection. d–h) Time‐dependent average absorption as a function of gas concentration integrated over a bandwidth of 400 nm around pt1, pt2, pt3, pt4, and pt5 spectral position, respectively. Increasing trend is observed for pt1, pt2, and pt5 whereas decreasing trend is observed for pt4. Average absorption is found to reach a maximum at intermediate concentration (80 ppm) at pt3 location.CC BY · PubMed Central
Figure 9 Characterization of 300 nm PEI film coated on a flat metal surface as exposed to a concentration of 1000 ppm followed by a flush with ambient CO2 gas at 75th second. The initial condition is maintained at ambient CO2 concentration, i.e., 600 ppm a). Broadband mid‐IR spectra of the three consecutive cases b). Time evolution of the signals at three distinct wavelengths of the spectra. Fast recovery of the PEI film is clearly observed at the bottom panel (R3) c). Dynamic response of metamaterial average absorption band (400 nm) around the two different wavelengths (pt1: 6 µm and pt2: 6.60 µm) as exposed to 1000 ppm CO2. Left inset: Broadband mid‐IR spectra at three instances: ti (initial condition: blue solid line), te (exposure: red solid line), and ts (steady state: black solid line). Right inset: Differential spectra at two instances: te and ts indicating large switching contrast achievable for detecting gas concentration above safety range.
Figure 9 Characterization of 300 nm PEI film coated on a flat metal surface as exposed to a concentration of 1000 ppm followed by a flush with ambient CO2 gas at 75th second. The initial condition is maintained at ambient CO2 concentration, i.e., 600 ppm a). Broadband mid‐IR spectra of the three consecutive cases b). Time evolution of the signals at three distinct wavelengths of the spectra. Fast recovery of the PEI film is clearly observed at the bottom panel (R3) c). Dynamic response of metamaterial average absorption band (400 nm) around the two different wavelengths (pt1: 6 µm and pt2: 6.60 µm) as exposed to 1000 ppm CO2. Left inset: Broadband mid‐IR spectra at three instances: ti (initial condition: blue solid line), te (exposure: red solid line), and ts (steady state: black solid line). Right inset: Differential spectra at two instances: te and ts indicating large switching contrast achievable for detecting gas concentration above safety range.CC BY · PubMed Central
Figure 10 a) Wavelength versus time mapping of resonance profile of hybrid metamaterial absorber structure (C9) as exposed to representative volatile organic compound (acetone vapor) at the 58th second. The structure is pre‐exposed to 177 ppm CO2 before acetone exposure. Presence of transient vibrational modes of acetone is indicated accordingly. b) Extracted resonance profiles at three different instances. Transient interferences caused by the acetone molecule are marked the gray region in the spectra. Only the pt4 and pt5 spectral locations are affected due to the transient coupling with the δ CH3 finger print of volatile organic compound.
Figure 10 a) Wavelength versus time mapping of resonance profile of hybrid metamaterial absorber structure (C9) as exposed to representative volatile organic compound (acetone vapor) at the 58th second. The structure is pre‐exposed to 177 ppm CO2 before acetone exposure. Presence of transient vibrational modes of acetone is indicated accordingly. b) Extracted resonance profiles at three different instances. Transient interferences caused by the acetone molecule are marked the gray region in the spectra. Only the pt4 and pt5 spectral locations are affected due to the transient coupling with the δ CH3 finger print of volatile organic compound.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Research works printed but not linked: 2

  1. Mori T., 2016, Proc. Micro Electro Mech. Syst. Invest. Micro Struct. Sens. Actuators Mach. Rob. Systems, 257
  2. Jelicic V., 2015, 2015 6th Int. Workshop Advances Sens. Interfaces, 271

Cited by

See all 173

Metadata

Authors
Hasan, D., & Lee, C.
Affiliations
National University of Singapore (SG)
Corresponding author
Lee, Chengkuo
Venue
Advanced Science
Publisher
Wiley
Published
2018-02-21
Volume
5
Issue
5
Pages
1700581-1700581
ISSN
2198-3844 (ISSN-L)
OpenAlex
W2789755800
Cited by
173
References
35
Citations by year
2026: 9 · 2025: 15 · 2024: 16 · 2023: 25 · 2022: 25 · 2021: 29 · 2020: 25 · 2019: 21 · 2018: 8
FWCI
7.93
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • National University of Singapore (submittedVersion)
Funders
National Natural Science Foundation of China (61474078)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
Keywords
CO2 gas sensing, mid-infrared absorption, metamaterial absorber, absorption enhancement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.