Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Understanding brain functions at the circuit level requires time‐resolved simultaneous measurement of a large number of densely distributed neurons, which remains a great challenge for current neural technologies. In particular, penetrating neural electrodes allow for recording from individual neurons at high temporal resolution, but often have larger dimensions than the biological matrix, which induces significant damage to brain tissues and therefore precludes the high implant density that is necessary for mapping large neuronal populations with full coverage. Here, it is demonstrated that nanofabricated ultraflexible electrode arrays with cross‐sectional areas as small as sub‐10 µm 2 can overcome this physical limitation. In a mouse model, it is shown that these electrodes record action potentials with high signal‐to‐noise ratio; their dense arrays allow spatial oversampling; and their multiprobe implantation allows for interprobe spacing at 60 µm without eliciting chronic neuronal degeneration. These results present the possibility of minimizing tissue displacement by implanted ultraflexible electrodes for scalable, high‐density electrophysiological recording that is capable of complete neuronal circuitry mapping over chronic time scales.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Carbon Nanotube Substrates Boost Neuronal Electrical Signaling
Lovat, V., Pantarotto, D., Lagostena, L., Cacciari, B., Grandolfo, M., Righi, M., Spalluto, G., Prato, M., & Ballerini, L. (2005) · Nano Letters · doi:10.1021/nl050637m · Cited by 648
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Cited by
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Self-citationStabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K., Ma, X., Miller, L. E., & Pandarinath, C. (2022) · doi:10.1101/2022.04.06.487388 · Cited by 71
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
Metadata
- Authors
- Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2018-03-10
- Volume
- 5
- Issue
- 6
- Pages
- 1700625-1700625
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W2792916769
- Cited by
- 146
- References
- 17
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording. https://app.cochat.ai/papers/10.1002/advs.201700625
- The paper
- Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C. (2018). Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording. Advanced Science. https://doi.org/10.1002/advs.201700625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.