Magnetically Guided Microcatheter for Targeted Injection of Magnetic Particle Swarms
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The initial delivery of small‐scale magnetic devices such as microrobots is a key, but often overlooked, aspect for their use in clinical applications. The deployment of these devices within the dynamic environment of the human body presents significant challenges due to their dispersion caused by circulatory flows. Here, a method is introduced to effectively deliver a swarm of magnetic nanoparticles in fluidic flows. This approach integrates a magnetically navigated robotic microcatheter equipped with a reservoir for storing the magnetic nanoparticles. The microfluidic flow within the reservoir facilitates the injection of magnetic nanoparticles into the fluid stream, and a magnetic field gradient guides the swarm through the oscillatory flow to a target site. The microcatheter and reservoir are engineered to enable magnetic steering and injection of the magnetic nanoparticles. To demonstrate this approach, experiments are conducted utilizing a spinal cord phantom simulating intrathecal catheter delivery for applications in the central nervous system. These results demonstrate that the proposed microcatheter successfully concentrates nanoparticles near the desired location through the precise manipulation of magnetic field gradients, offering a promising solution for the controlled deployment of untethered magnetic micro‐/nanodevices within the complex physiological circulatory systems of the human body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dobrovolskaia, M. A., Aggarwal, P., Hall, J. B., & McNeil, S. E. (2008) · Molecular Pharmaceutics · doi:10.1021/mp800032f · Cited by 1,022
Mechanisms of fluid movement into, through and out of the brain: evaluation of the evidence
Hladky, S. B., & Barrand, M. A. (2014) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-11-26 · Cited by 633
Iron Oxide Nanoparticles for Magnetically-Guided and Magnetically-Responsive Drug Delivery
Estelrich, J., Escribano, E., Queralt, J., & Busquets, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16048070 · Cited by 532
Research works printed but not linked: 40
- 10.1126/science.adh3073 · DOI · Paper page
- 10.1126/scirobotics.abd2813 · DOI · Paper page
- 10.1039/C4CS00345D · DOI · Paper page
- 10.1002/chem.201903475 · DOI
- 10.1002/smll.201101909 · DOI · Paper page
- 10.1002/advs.202004458 · DOI
- 10.1038/nnano.2011.112 · DOI · Paper page
- 10.1021/acsnano.3c06085 · DOI
- 10.1002/adma.201901592 · DOI · Paper page
- 10.1002/adhm.202001031 · DOI
- Landers F. C., 2023, Adv. Mater.
- 10.1038/s41467-018-05749-6 · DOI · Paper page
- 10.1038/s41467-019-13576-6 · DOI · Paper page
- 10.1021/acs.accounts.1c00619 · DOI
- 10.3390/nano11112991 · DOI
- 10.1038/s41536-018-0046-3 · DOI
- 10.1038/s42256-022-00510-7 · DOI
- 10.1002/advs.201800807 · DOI
- 10.3389/fnbot.2021.749024 · DOI
- 10.1002/advs.202101290 · DOI
- 10.1002/advs.202103277 · DOI
- 10.1055/s-2006-948000 · DOI
- 10.1016/j.apt.2016.06.029 · DOI
- 10.1146/annurev-chembioeng-060718-030203 · DOI
- 10.1016/j.addr.2010.05.006 · DOI · Paper page
- 10.1021/cn100100e · DOI · Paper page
- 10.1016/j.colsurfb.2015.11.028 · DOI
- 10.3389/fpain.2022.900566 · DOI
- 10.3109/2000656X.2015.1058269 · doi:10.3109/2000656x.2015.1058269
- 10.1016/j.jclinane.2017.03.025 · doi:10.1016/j.jclinane.2017.03.025
- 10.1213/00000539-199412000-00014 · doi:10.1213/00000539-199412000-00014
- 10.4097/kjae.2000.39.5.651 · doi:10.4097/kjae.2000.39.5.651
- 10.1080/02688699550040927 · doi:10.1080/02688699550040927
- 10.1016/0730-725X(93)90238-9 · DOI
- 10.2217/nnm.13.69 · DOI
- 10.1186/s12987-017-0085-y · DOI
- 10.1016/j.amc.2012.11.071 · DOI
- 10.1137/120903385 · DOI
- 10.1371/journal.pone.0173680 · DOI
- 10.1080/10255842.2017.1393805 · DOI
Cited by
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., et al. (2025) · Science Advances · doi:10.1126/sciadv.adv1682 · Cited by 36
Metadata
- Authors
- Torlakcik, H., Sevim, S., Alves, P., Mattmann, M., Llacer‐Wintle, J., Pinto, M., Moreira, R., Flouris, A. D., Landers, F. C., Chen, X., Puigmartí‐Luis, J., Boehler, Q., Mayor, T. S., Kim, M., Nelson, B. J., & Pané, S.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2024-08-09
- Volume
- 11
- Issue
- 38
- ISSN
- 2198-3844
- Cited by
- 21
- References
- 3
- Language
- en
- Funders
- European Research Council (771565)
- Eidgenössische Technische Hochschule Zürich (22‐2 ETH‐040)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (198643, 197017)
- H2020 Future and Emerging Technologies (952152)
- H2020 European Research Council (801464)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetically Guided Microcatheter for Targeted Injection of Magnetic Particle Swarms. https://app.cochat.ai/papers/10.1002/advs.202404061
- The paper
- Torlakcik, H., Sevim, S., Alves, P., Mattmann, M., Llacer‐Wintle, J., Pinto, M., Moreira, R., Flouris, A. D., Landers, F. C., Chen, X., Puigmartí‐Luis, J., Boehler, Q., Mayor, T. S., Kim, M., Nelson, B. J., & Pané, S. (2024). Magnetically Guided Microcatheter for Targeted Injection of Magnetic Particle Swarms. Advanced Science. https://doi.org/10.1002/advs.202404061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.