Integrated medical feedback systems for drug delivery
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Drugs are now administered at frequencies and doses based on averages optimized for large populations. Because the optimal frequency and dose for an individual differs, transiently or permanently, from that of a population's average, the dosing is necessarily suboptimal. Feedback loop‐based individualized integrated medical systems, comprising an implanted sensor, battery, amplifier, processor, and actuator are now in use in cardiac pacemakers and defibrillators. Drug‐delivering medical feedback loops, comprising miniature sensors and drug pumps, would individualize, and thereby improve the effectiveness and safety of drugs. Their sensor would continuously or frequently monitor the effect of the drug and adjust, through a medical control algorithm, its flow to the minimum necessary for effectiveness, reducing thereby side effects and improving the success rate of experimental drugs. The pace of integration of the drug delivering feedback loops depends on the availability of proven miniature components and of medical control algorithms. © 2005 American Institute of Chemical Engineers AIChE J, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Catalysis for Low Temperature Fuel Cells: PART I: THE CATHODE CHALLENGES
Ralph, T. R., & Hogarth, M. P. (2002) · Platinum Metals Review · doi:10.1595/003214002x461314 · Cited by 338
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citationQuinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Self-citationBiocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Self-citation
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationPolymers for Drug Delivery Systems
Liechty, W. B., Kryscio, D. R., Slaughter, B. V., & Peppas, N. A. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100847 · Cited by 1,608
Recent advances in polymeric drug delivery systems
Sung, Y. K., & Kim, S. W. (2020) · Biomaterials Research · doi:10.1186/s40824-020-00190-7 · Cited by 732
Enzymatic fuel cells: Recent progress
Leech, D., Kavanagh, P., & Schuhmann, W. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.02.087 · Cited by 446
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021) · Sensors · doi:10.3390/s21144672 · Cited by 364
Electron-conducting redox hydrogels: design, characteristics and synthesis
Heller, A. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.09.018 · Cited by 352
Self-citationO2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Application of Micro- and Nano-Electromechanical Devices to Drug Delivery
Staples, M., Daniel, K., Cima, M. J., & Langer, R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9906-4 · Cited by 311
The significance of artificial intelligence in drug delivery system design
Hassanzadeh, P., Atyabi, F., & Dinarvand, R. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.05.001 · Cited by 305
Biosensors and bioelectrochemistry
Murphy, L. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.02.023 · Cited by 225
Recent Advances in Enzymatic Fuel Cells: Experiments and Modeling
Ivanov, I., Vidaković-Koch, T., & Sundmacher, K. (2010) · Energies · doi:10.3390/en3040803 · Cited by 212
“, for diabetes monitoring and control [34].”
Wang, J., & Katz, E. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3746-0 · Cited by 170
Hydrogel-based biosensors and sensing devices for drug delivery
Peppas, N. A., & Van Blarcom, D. S. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.11.022 · Cited by 164
Metadata
- Authors
- Heller, A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2005-03-08
- Volume
- 51
- Issue
- 4
- Pages
- 1054-1066
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2084045663
- Cited by
- 117
- References
- 4
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.