Concurrent monitoring of operating condition deviations and process dynamics anomalies with slow feature analysis
Open accessAbstract
Latent variable (LV) models have been widely used in multivariate statistical process monitoring. However, whatever deviation from nominal operating condition is detected, an alarm is triggered based on classical monitoring methods. Therefore, they fail to distinguish real faults incurring dynamics anomalies from normal deviations in operating conditions. A new process monitoring strategy based on slow feature analysis (SFA) is proposed for the concurrent monitoring of operating point deviations and process dynamics anomalies. Slow features as LVs are developed to describe slowly varying dynamics, yielding improved physical interpretation. In addition to classical statistics for monitoring deviation from design conditions, two novel indices are proposed to detect anomalies in process dynamics through the slowness of LVs. The proposed approach can distinguish whether the changes in operating conditions are normal or real faults occur. Two case studies show the validity of the SFA‐based process monitoring approach. © 2015 American Institute of Chemical Engineers AIChE J, 61: 3666–3682, 2015
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Casella, G., & Berger, R. (2024) · Chapman & Hall/CRC eBooks · doi:10.1201/9781003456285 · Cited by 5,711
A plant-wide industrial process control problem
Downs, J. J., & Vogel, E. F. (1993) · Computers & Chemical Engineering · doi:10.1016/0098-1354(93)80018-i · Cited by 3,348
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Disturbance detection and isolation by dynamic principal component analysis
Ku, W., Storer, R. H., & Georgakis, C. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00076-3 · Cited by 1,483
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Fault Detection and Diagnosis in Industrial Systems
Braatz, L. H. C. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/10/706 · Cited by 1,416
Slow Feature Analysis: Unsupervised Learning of Invariances
Wiskott, L., & Sejnowski, T. J. (2002) · Neural Computation · doi:10.1162/089976602317318938 · Cited by 1,350
Fault Detection and Diagnosis in Industrial Systems
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9 · Cited by 1,318
Yin, S., Ding, S. X., Haghani, A., Hao, H., & Zhang, P. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.06.009 · Cited by 1,294
Control Procedures for Residuals Associated With Principal Component Analysis
Jackson, J. E., & Mudholkar, G. S. (1979) · Technometrics · doi:10.1080/00401706.1979.10489779 · Cited by 1,237
The process chemometrics approach to process monitoring and fault detection
Wise, B. M., & Gallagher, N. B. (1996) · Journal of Process Control · doi:10.1016/0959-1524(96)00009-1 · Cited by 852
Process monitoring and diagnosis by multiblock PLS methods
MacGregor, J. F., Jaeckle, C., Kiparissides, C., & Koutoudi, M. (1994) · AIChE Journal · doi:10.1002/aic.690400509 · Cited by 773
Statistical process monitoring with independent component analysis
Lee, J.-M., Yoo, C., & Lee, I.-B. (2004) · Journal of Process Control · doi:10.1016/j.jprocont.2003.09.004 · Cited by 746
Valle, S., Li, W., & Qin, S. J. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie990110i · Cited by 549
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00058-7 · Cited by 525
On-line batch process monitoring using dynamic PCA and dynamic PLS models
Chen, J., & Liu, K.-C. (2002) · Chemical Engineering Science · doi:10.1016/s0009-2509(01)00366-9 · Cited by 431
Fault detection and diagnosis based on modified independent component analysis
Lee, J., Qin, S. J., & Lee, I. (2006) · AIChE Journal · doi:10.1002/aic.10978 · Cited by 419
Monitoring independent components for fault detection
Kano, M., Tanaka, S., Hasebe, S., Hashimoto, I., & Ohno, H. (2003) · AIChE Journal · doi:10.1002/aic.690490414 · Cited by 410
Subspace approach to multidimensional fault identification and reconstruction
Dunia, R. H., & Qin, S. J. (1998) · AIChE Journal · doi:10.1002/aic.690440812 · Cited by 382
Principal Components and Factor Analysis: Part I—Principal Components
Jackson, J. E. (1980) · Journal of Quality Technology · doi:10.1080/00224065.1980.11980967 · Cited by 373
Slow Feature Analysis for Change Detection in Multispectral Imagery
Wu, C., Du, B., & Zhang, L. (2014) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2013.2266673 · Cited by 349
Slow feature analysis for human action recognition
Zhang, Z., & Tao, D. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.157 · Cited by 307
Slow feature analysis yields a rich repertoire of complex cell properties
Berkes, P., & Wiskott, L. (2005) · Journal of Vision · doi:10.1167/5.6.9 · Cited by 280
Monitoring, fault diagnosis, fault-tolerant control and optimization: Data driven methods
MacGregor, J., & Cinar, A. (2012) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2012.06.017 · Cited by 277
Qin, S. J., & Zheng, Y. (2013) · AIChE Journal · doi:10.1002/aic.13959 · Cited by 263
Statistical monitoring of multivariable dynamic processes with state‐space models
Negiz, A., & Çlinar, A. (1997) · AIChE Journal · doi:10.1002/aic.690430810 · Cited by 259
Isolation and handling of actuator faults in nonlinear systems
Mhaskar, P., McFall, C., Gani, A., Christofides, P. D., & Davis, J. F. (2008) · Automatica · doi:10.1016/j.automatica.2007.05.006 · Cited by 230
Reconstruction based fault prognosis for continuous processes
Li, G., Qin, S. J., Ji, Y., et al. (2010) · Control Engineering Practice · doi:10.1016/j.conengprac.2010.05.012 · Cited by 140
How are complex cell properties adapted to the statistics of natural stimuli?
Körding, K. P., Kayser, C., Einhäuser, W., & König, P. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00149.2003 · Cited by 121
A Maximum-Likelihood Interpretation for Slow Feature Analysis
Turner, R. E., & Sahani, M. (2007) · Neural Computation · doi:10.1162/neco.2007.19.4.1022 · Cited by 107
Isolation and handling of sensor faults in nonlinear systems
Du, M., & Mhaskar, P. (2014) · Automatica · doi:10.1016/j.automatica.2014.02.017 · Cited by 101
Enhancing dynamic soft sensors based on DPLS: A temporal smoothness regularization approach
Shang, C., Huang, X., Suykens, J. A. K., & Huang, D. (2015) · Journal of Process Control · doi:10.1016/j.jprocont.2015.02.006 · Cited by 77
Self-citationWhat Is the Relation Between Slow Feature Analysis and Independent Component Analysis?
Blaschke, T., Berkes, P., & Wiskott, L. (2006) · Neural Computation · doi:10.1162/neco.2006.18.10.2495 · Cited by 76
Independent Slow Feature Analysis and Nonlinear Blind Source Separation
Blaschke, T., Zito, T., & Wiskott, L. (2007) · Neural Computation · doi:10.1162/neco.2007.19.4.994 · Cited by 60
An extension of slow feature analysis for nonlinear blind source separationPreprint
Sprekeler, H., Zito, T., & Wiskott, L. (2014) · CogPrints (University of Southampton) · Cited by 56
Negiz, A., & Çınar, A. (1997) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(97)00035-x · Cited by 53
Cited by
Shang, C., & You, F. (2019) · Engineering · doi:10.1016/j.eng.2019.01.019 · Cited by 332
Self-citation
Metadata
- Authors
- Shang, C., Yang, F., Gao, X., Huang, X., Suykens, J. A. K., & Huang, D.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2015-06-08
- Volume
- 61
- Issue
- 11
- Pages
- 3666-3682
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2111637385
- Cited by
- 300
- References
- 38
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.