The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Multiscale PCA with application to multivariate statistical process monitoring
Abstract
Multiscale principal‐component analysis (MSPCA) combines the ability of PCA to decorrelate the variables by extracting a linear relationship with that of wavelet analysis to extract deterministic features and approximately decorrelate autocorrelated measurements. MSPCA computes the PCA of wavelet coefficients at each scale and then combines the results at relevant scales. Due to its multiscale nature, MSPCA is appropriate for the modeling of data containing contributions from events whose behavior changes over time and frequency. Process monitoring by MSPCA involves combining only those scales where significant events are detected, and is equivalent to adaptively filtering the scores and residuals, and adjusting the detection limits for easiest detection of deterministic changes in the measurements. Approximate decorrelation of wavelet coefficients also makes MSPCA effective for monitoring autocorrelated measurements without matrix augmentation or time‐series modeling. In addition to improving the ability to detect deterministic changes, monitoring by MSPCA also simultaneously extracts those features that represent abnormal operation. The superior performance of MSPCA for process monitoring is illustrated by several examples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
Orthonormal bases of compactly supported wavelets
Daubechies, I. (1988) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160410705 · Cited by 8,190
A User's Guide to Principal Components
Leigh, S., & Jackson, J. E. (1993) · Technometrics · doi:10.2307/1269292 · Cited by 3,332
Nonlinear principal component analysis using autoassociative neural networks
Kramer, M. A. (1991) · AIChE Journal · doi:10.1002/aic.690370209 · Cited by 3,037
A Use's Guide to Principal Components
Jackson, J. E. (1991) · Wiley Series in Probability and Statistics · doi:10.1002/0471725331 · Cited by 2,516
Blackwood, L. G., & Malinowski, E. R. (1994) · Technometrics · doi:10.2307/1269209 · Cited by 2,210
Briggs, W. L. (1987) · Cited by 1,868
Wavelet Shrinkage: Asymptopia?
Donoho, D. L., Johnstone, I. M., Kerkyacharian, G., & Picard, D. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02032.x · Cited by 1,749
(1992) · Analytica Chimica Acta · doi:10.1016/0003-2670(92)85390-r · Cited by 1,550
Cited by
A review of process fault detection and diagnosis
Venkatasubramanian, V., Rengaswamy, R., Yin, K., & Kavuri, S. N. (2003) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00160-6 · Cited by 2,723
A review of process fault detection and diagnosis
Venkatasubramanian, V., Rengaswamy, R., Kavuri, S. N., & Yin, K. (2003) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00162-x · Cited by 1,859
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Nonlinear process monitoring using kernel principal component analysis
Lee, J.-M., Yoo, C., Choi, S. W., Vanrolleghem, P. A., & Lee, I.-B. (2004) · Chemical Engineering Science · doi:10.1016/j.ces.2003.09.012 · Cited by 1,086
Statistical process monitoring with independent component analysis
Lee, J.-M., Yoo, C., & Lee, I.-B. (2004) · Journal of Process Control · doi:10.1016/j.jprocont.2003.09.004 · Cited by 746
Review of adaptation mechanisms for data-driven soft sensors
Kadlec, P., Grbić, R., & Gabrys, B. (2011) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2010.07.034 · Cited by 517
Kano, M., & Nakagawa, Y. (2008) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2007.07.005 · Cited by 508
Multimode process monitoring with Bayesian inference‐based finite Gaussian mixture models
Yu, J., & Qin, S. J. (2008) · AIChE Journal · doi:10.1002/aic.11515 · Cited by 494
Kevric, J., & Subasi, A. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.007 · Cited by 428
Monitoring independent components for fault detection
Kano, M., Tanaka, S., Hasebe, S., Hashimoto, I., & Ohno, H. (2003) · AIChE Journal · doi:10.1002/aic.690490414 · Cited by 410
Alickovic, E., Kevric, J., & Subasi, A. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.07.022 · Cited by 407
Multivariate process monitoring and fault diagnosis by multi-scale PCA
Misra, M., Yue, H. H., Qin, S. J., & Ling, C. (2002) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00093-5 · Cited by 325
Ensemble SVM Method for Automatic Sleep Stage Classification
Alickovic, E., & Subasi, A. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2799059 · Cited by 313
Fault identification for process monitoring using kernel principal component analysis
Cho, J.-H., Lee, J.-M., Wook Choi, S., Lee, D., & Lee, I.-B. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.08.007 · Cited by 305
Multiscale Energy and Eigenspace Approach to Detection and Localization of Myocardial Infarction
Sharma, L. N., Tripathy, R. K., & Dandapat, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2405134 · Cited by 296
Ge, Z., & Song, Z. (2007) · Industrial & Engineering Chemistry Research · doi:10.1021/ie061083g · Cited by 294
Reis, M., & Gins, G. (2017) · Processes · doi:10.3390/pr5030035 · Cited by 294
Intelligent integrated plant operation system for Six Sigma
Han, C., & Lee, Y.-H. (2002) · Annual Reviews in Control · doi:10.1016/s1367-5788(02)80008-6 · Cited by 63
Mwale, D., & Gan, T. Y. (2005) · Journal of Applied Meteorology and Climatology · doi:10.1175/jam2195.1 · Cited by 50
Vallone, F., Ottaviani, M. M., Dedola, F., Cutrone, A., Romeni, S., Panarese, A. M., Bernini, F., Cracchiolo, M., Strauss, I., Gabisonia, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d42 · Cited by 35
“Principal component analysis on the multivariate wavelet details was applied independently at two different scales [45] relative to frequency ranges of ∼ = 1500–3000 Hz and 3000–6000 Hz, respectively.”
Metadata
- Authors
- Bakshi, B. R.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1998-07
- Volume
- 44
- Issue
- 7
- Pages
- 1596-1610
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W1993694278
- Cited by
- 839
- References
- 37
- FWCI
- 29.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.