Maximum stable bubble size and gas holdup in high‐pressure slurry bubble columns
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Experiments of pressure effects on gas holdup and bubble size in slurry bubble columns at 5.6 MPa and at gas velocities up to 45 cm/s indicate that the gas holdup increases with an increase in pressure, especially at high slurry concentration. At ambient pressure, a higher solids concentration significantly lowers gas holdup over the entire gas‐velocity range, while at 5.6 MPa, the effect of solids concentration on gas holdup is relatively small at gas velocities above 25 cm/s. An empirical correlation was developed based on these data and those in the literature to predict gas holdup in bubble and slurry bubble columns over a wide range of operating conditions. An analysis of bubble flow characteristics during dynamic gas disengagement indicates that large bubbles play a key role in determining gas holdup due to the large bubble and wake volumes that induce the acceleration of small bubbles. Direct measurement of bubble size shows that elevated pressures lead to smaller bubble size and narrower bubble‐size distributions. Bubble size increases significantly with increasing solids concentration at ambient pressure, while at high pressures this effect is less pronounced. A theoretical analysis of circulation of gas inside the bubble yields an analytical expression for maximum stable bubble size in high‐pressure slurry bubble columns. Based on this internal circulation model, the maximum stable bubble size at high pressures is significantly smaller due to the high gas inertia and low gas–liquid surface tension. The smaller bubble size and its reduced bubble rise velocity account for the observed pressure effect on gas holdup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design parameters estimations for bubble column reactors
Shah, Y. T., Kelkar, B. G., Godbole, S. P., & Deckwer, W. ‐. (1982) · AIChE Journal · doi:10.1002/aic.690280302 · Cited by 1,202
Gas Holdup and Volumetric Mass Transfer Coefficient in Bubble Columns. Effects of Liquid Properties
Akita, K., & Yoshida, F. (1973) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260045a015 · Cited by 684
Cited by
Kantarci, N., Borak, F., & Ulgen, K. O. (2005) · Process Biochemistry · doi:10.1016/j.procbio.2004.10.004 · Cited by 1,057
“[4], gas holdup was found to be strongly affected by the type of gas distributor.”
BackgroundInfluentialA novel theoretical breakup kernel function for bubbles/droplets in a turbulent flow
Wang, T., Wang, J., & Jin, Y. (2003) · Chemical Engineering Science · doi:10.1016/j.ces.2003.07.009 · Cited by 260
Bubble size distributions in a bubble column reactor under industrial conditions
Schäfer, R., Merten, C., & Eigenberger, G. (2002) · Experimental Thermal and Fluid Science · doi:10.1016/s0894-1777(02)00189-9 · Cited by 217
Two-Phase Bubble Columns: A Comprehensive Review
Besagni, G., Inzoli, F., & Ziegenhein, T. (2018) · ChemEngineering · doi:10.3390/chemengineering2020013 · Cited by 190
Heat Transfer in a Slurry Bubble Column Reactor: A Critical Overview
Jhawar, A. K., & Prakash, A. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie201108b · Cited by 41
Kantarci, N., Ulgen, K. O., & Borak, F. (2005) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450830417 · Cited by 34
Metadata
- Authors
- Luo, X., Lee, D. J., Lau, R., Yang, G., & Fan, L.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1999-04
- Volume
- 45
- Issue
- 4
- Pages
- 665-680
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2153744792
- Cited by
- 250
- References
- 2
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.