The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Cavitation reactors: Efficiency assessment using a model reaction
Abstract
Acoustic and hydrodynamic cavitation can be used for a variety of applications ranging from biological applications such as cell disruption to chemical reactions such as oxidation of organic pollutants in aqueous effluents, including biorefractory toxic chemicals. Different equipment used for cavitational effects was compared based on a model reaction (decomposition of potassium iodide resulting into iodine liberation). A correlation was developed for the prediction of the cavitational yield in terms of the cavity collapse pressure. This correlation, when used with earlier correlations for the pressure amplitude generated during the violent collapse of cavities, will help design engineers to choose particular equipment, operating conditions, and geometric parameters to achieve a desired chemical change. The developed equation relating the macroscopic reaction rates with the collapse pressure is the first of its kind reported in the literature. Pilot‐plant‐scale hydrodynamic cavitation orifice plate setup is most energy‐efficient, with significantly higher cavitational yields for the model reaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic cavitation and its chemical consequences
Suslick, K. S., Didenko, Y., Fang, M. M., Hyeon, T., Kolbeck, K. J., McNamara, W. B., Mdleleni, M. M., & Wong, M. (1999) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.1999.0330 · Cited by 810
Mechanisms of impulsive pressure generation and damage pit formation by bubble collapse
Tomita, Y., & Shima, A. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086000745 · Cited by 616
Optimization of Ultrasonic Irradiation as an Advanced Oxidation Technology
Hua, I., & Hoffmann, M. R. (1997) · Environmental Science & Technology · doi:10.1021/es960717f · Cited by 435
Wastewater treatment: a novel energy efficient hydrodynamic cavitational technique
Sivakumar, M., & Pandit, A. B. (2002) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(01)00122-5 · Cited by 325
Self-citationCavitation Reaction Engineering
Shah, Y. T., Pandit, A. B., & Moholkar, V. S. (1999) · The Plenum Chemical Engineering Series · doi:10.1007/978-1-4615-4787-7 · Cited by 299
Self-citationHYDRODYNAMIC CAVITATION REACTORS: A STATE OF THE ART REVIEW
Gogate, P. R., & Pandit, A. B. (2001) · Reviews in Chemical Engineering · doi:10.1515/revce.2001.17.1.1 · Cited by 289
Self-citationUltrasound enhanced degradation of Rhodamine B: optimization with power density
Sivakumar, M., & Pandit, A. B. (2001) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(01)00082-7 · Cited by 287
Self-citationCavitation: an auxiliary technique in wastewater treatment schemes
Gogate, P. R. (2002) · Advances in Environmental Research · doi:10.1016/s1093-0191(01)00067-3 · Cited by 275
Self-citationEngineering design methods for cavitation reactors II: Hydrodynamic cavitation
Gogate, P. R., & Pandit, A. B. (2000) · AIChE Journal · doi:10.1002/aic.690460815 · Cited by 252
Self-citationAromatic Compound Degradation in Water Using a Combination of Sonolysis and Ozonolysis
Weavers, L. K., Ling, F. H., & Hoffmann, M. R. (1998) · Environmental Science & Technology · doi:10.1021/es970675a · Cited by 243
Cited by
A standard method to calibrate sonochemical efficiency of an individual reaction system
Koda, S., Kimura, T., Kondo, T., & Mitome, H. (2003) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(03)00084-1 · Cited by 778
A review of imperative technologies for wastewater treatment II: hybrid methods
Gogate, P. R., & Pandit, A. B. (2004) · Advances in Environmental Research · doi:10.1016/s1093-0191(03)00031-5 · Cited by 769
Self-citationAdvances in ultrasound assisted extraction of bioactive compounds from cash crops–A review
Wen, C., Zhang, J., Zhang, H., Dzah, C. S., Zandile, M., Duan, Y., Ma, H., & Luo, X. (2018) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2018.07.018 · Cited by 721
A review of applications of cavitation in biochemical engineering/biotechnology
Gogate, P. R., & Kabadi, A. M. (2009) · Biochemical Engineering Journal · doi:10.1016/j.bej.2008.10.006 · Cited by 664
Self-citationGogate, P. R. (2008) · Chemical Engineering and Processing: Process Intensification · doi:10.1016/j.cep.2007.09.014 · Cited by 525
Self-citationUltrasound-enhanced conversion of biomass to biofuels
Luo, J., Fang, Z., & Smith, R. L. (2014) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2013.11.001 · Cited by 421
A review and assessment of hydrodynamic cavitation as a technology for the future
Gogate, P. R., & Pandit, A. B. (2005) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2004.03.007 · Cited by 353
Self-citationBhat, A. P., & Gogate, P. R. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123657 · Cited by 308
Self-citationCavitation: an auxiliary technique in wastewater treatment schemes
Gogate, P. R. (2002) · Advances in Environmental Research · doi:10.1016/s1093-0191(01)00067-3 · Cited by 275
Self-citationUltrasonic atomization: Effect of liquid phase properties
Avvaru, B., Patil, M. N., Gogate, P. R., & Pandit, A. B. (2006) · Ultrasonics · doi:10.1016/j.ultras.2005.09.003 · Cited by 260
Self-citationUltrasound-intensified mineral carbonation
Santos, R. M., François, D., Mertens, G., Elsen, J., & Van Gerven, T. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.03.035 · Cited by 141
The secondary Bjerknes force between two gas bubbles under dual-frequency acoustic excitation
Zhang, Y., Zhang, Y., & Li, S. (2016) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2015.08.022 · Cited by 134
Ma, H., Huang, L., Peng, L., Wang, Z., & Yang, Q. (2015) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2014.10.020 · Cited by 40
Metadata
- Authors
- Gogate, P. R., Shirgaonkar, I. Z., Sivakumar, M., Senthilkumar, P., Vichare, N. P., & Pandit, A. B.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2001-11
- Volume
- 47
- Issue
- 11
- Pages
- 2526-2538
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2076148263
- Cited by
- 306
- References
- 31
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.