A randomized, double‐blind, phase 2 study of erythropoietin in optic neuritis

Sühs, Kurt‐Wolfram, Hein, Katharina, Sättler, Muriel B., Görlitz, Anke, Ciupka, Christoph, Scholz, Kerstin, Käsmann‐Kellner, Barbara, Papanagiotou, Panagiotis, Schäffler, Nina, Restemeyer, Cordula, Bittersohl, Diana, Hassenstein, Andrea, Seitz, Berthold, Reith, Wolfgang, Fassbender, Klaus, Hilgers, Reinhard, Heesen, Christoph, Bähr, Mathias, Diem, Ricarda · 2012 · Annals of Neurology
Cited by 155

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: Based on findings in animal models of autoimmune optic nerve inflammation, we have assessed the safety and efficacy of erythropoietin in patients presenting with a first episode of optic neuritis. Methods: Patients with optic neuritis who attended the University Hospitals of Homburg/Saar, Göttingen, or Hamburg (Germany) were included in this double‐blind, placebo‐controlled, phase 2 study (ClinicalTrials.gov, NCT00355095). They were randomly assigned to groups receiving either 33,000IU recombinant human erythropoietin intravenously daily for 3 days or placebo as an add‐on therapy to methylprednisolone. The primary outcome parameter was change in retinal nerve fiber layer (RNFL) thickness after 16 weeks. Secondary outcome parameters included optic nerve atrophy as assessed by magnetic resonance imaging, and changes in visual acuity, visual field, and visual evoked potentials (VEPs). Results: Forty patients were assigned to the treatment groups (21/19 erythropoietin/placebo). Safety monitoring revealed no relevant issues. Thirty‐seven patients (20/17 erythropoietin/placebo) were analyzed for the primary endpoint according to the intention‐to‐treat protocol. RNFL thinning was less apparent after erythropoietin treatment. Thickness of the RNFL decreased by a median of 7.5μm by week 16 (mean ± standard deviation, 10.55 ± 17.54μm) compared to a median of 16.0μm (22.65 ± 29.18μm) in the placebo group (p = 0.0357). Decrease in retrobulbar diameter of the optic nerve was smaller in the erythropoietin group (p = 0.0112). VEP latencies at week 16 were shorter in erythropoietin‐treated patients than in the placebo group (p = 0.0011). Testing of visual functions revealed trends toward an improved outcome after erythropoietin treatment. Interpretation: These results give the first indications that erythropoietin might be neuroprotective in optic neuritis. ANN NEUROL 2012;72:199–210.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.23573

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 155

Metadata

Authors
Sühs, K., Hein, K., Sättler, M. B., Görlitz, A., Ciupka, C., Scholz, K., Käsmann‐Kellner, B., Papanagiotou, P., Schäffler, N., Restemeyer, C., Bittersohl, D., Hassenstein, A., Seitz, B., Reith, W., Fassbender, K., Hilgers, R., Heesen, C., Bähr, M., & Diem, R.
Venue
Annals of Neurology
Publisher
Wiley
Published
2012-08
Volume
72
Issue
2
Pages
199-210
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2059528602
Cited by
155
References
2
FWCI
8.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.