CoChat

Hydrolytically Stable Ionic Fluorogels for High‐Performance Remediation of Per‐ and Polyfluoroalkyl Substances (PFAS) from Natural Water

Open access

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.

Abstract

PFAS are known bioaccumulative and persistent chemicals which pollute natural waters globally. There exists a lack of granular sorbents to efficiently remove both legacy and emerging PFAS at environmentally relevant concentrations. Herein, we report a class of polymer networks with a synergistic combination of ionic and fluorous components that serve as granular materials for the removal of anionic PFAS from water. A library of Ionic Fluorogels (IFs) with systematic variation in charge density and polymer network architecture was synthesized from hydrolytically stable fluorous building blocks. The IFs were demonstrated as effective sorbents for the removal of 21 legacy and emerging PFAS from a natural water and were regenerable over multiple cycles of reuse. Comparison of one IF to a commercial ion exchange resin in mini‐rapid small‐scale column tests demonstrated superior performance for the removal of short‐chain PFAS from natural water under operationally relevant conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ange.202208150

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 A) Previously reported Ionic Fluorogels leveraged carbamateterminated Fluorolink ® MD700 for selective PFAS remediation from water. B) This work uses chain-end modified PFPEs to enable an IF that demonstrates chemical stability and excellent performance under conditions relevant to commercial use.
Figure 1 A) Previously reported Ionic Fluorogels leveraged carbamateterminated Fluorolink ® MD700 for selective PFAS remediation from water. B) This work uses chain-end modified PFPEs to enable an IF that demonstrates chemical stability and excellent performance under conditions relevant to commercial use.CC-BY-NC · From the PDF
Image 2
CC-BY-NC · From the PDF
Image 3
CC-BY-NC · From the PDF
Image 4
CC-BY-NC · From the PDF
Figure 2 A) Synthesis of PFPE crosslinkers (PFPEs starting materials shown in shaded inset). B) Synthesis of Ionic Fluorogel formulations (denoted as IF-X), with varied compositions of PFS-E10H, PFS-FTEG, and 1 . Resulting crosslinked materials after polymerization were ground and sieved to obtain resin particles 75-125 um.
Figure 2 A) Synthesis of PFPE crosslinkers (PFPEs starting materials shown in shaded inset). B) Synthesis of Ionic Fluorogel formulations (denoted as IF-X), with varied compositions of PFS-E10H, PFS-FTEG, and 1 . Resulting crosslinked materials after polymerization were ground and sieved to obtain resin particles 75-125 um.CC-BY-NC · From the PDF
Image 6
CC-BY-NC · From the PDF
Image 7
CC-BY-NC · From the PDF
Figure 4 A) Time dependent GenX sorption by IF-1 ([GenX] 0 = 1 μgL 1 ; [IF-1] = 10 mgL 1 ). pH 9.7. B) GenX Sorption Isotherm by IF-1 ([IF1] = 100 mgL 1 ; [GenX]0 = 0.2-50 mgL 1 ). Lines show fit to Langmuir (red, solid) and Freundlich (blue, dashed) models. C) Regeneration and reuse over 5 cycles of IF-1. IF-1 = 20 mg, [GenX] = 18 mgL 1 (20 mL); extraction with 400 mM ammonium acetate in 1:1 EtOH:H2O (20 mL). Error bars: Standard deviation of 3 experiments.
Figure 4 A) Time dependent GenX sorption by IF-1 ([GenX] 0 = 1 μgL 1 ; [IF-1] = 10 mgL 1 ). pH 9.7. B) GenX Sorption Isotherm by IF-1 ([IF1] = 100 mgL 1 ; [GenX]0 = 0.2-50 mgL 1 ). Lines show fit to Langmuir (red, solid) and Freundlich (blue, dashed) models. C) Regeneration and reuse over 5 cycles of IF-1. IF-1 = 20 mg, [GenX] = 18 mgL 1 (20 mL); extraction with 400 mM ammonium acetate in 1:1 EtOH:H2O (20 mL). Error bars: Standard deviation of 3 experiments.CC-BY-NC · From the PDF
Figure 5 A) Mass loss of IF-20 + (red triangles) and IF-1 (blue diamonds) over 56 days. pH 8.7, 50 ° C. Error bars: standard deviation of 3 experiments. Discs were washed with methanol before drying to determine mass loss. B) Averaged area counts (duplicate samples) of the 5 most-intense peaks detected via nontargeted analysis of the extracts after washing the samples from day 28 of the mass loss study in methanol. The m / z values varied by combinations of 49.99, 65.99, and 115.99, indicative of PFPE repeat units.
Figure 5 A) Mass loss of IF-20 + (red triangles) and IF-1 (blue diamonds) over 56 days. pH 8.7, 50 ° C. Error bars: standard deviation of 3 experiments. Discs were washed with methanol before drying to determine mass loss. B) Averaged area counts (duplicate samples) of the 5 most-intense peaks detected via nontargeted analysis of the extracts after washing the samples from day 28 of the mass loss study in methanol. The m / z values varied by combinations of 49.99, 65.99, and 115.99, indicative of PFPE repeat units.CC-BY-NC · From the PDF
Figure 6 Batch equilibrium adsorption of 21 PFAS by IF -1. [PFAS] 0 = 1 μgL 1 each. Settled conventional water, OWASA, Chapel Hill, NC. Experiment time: 24 hours. Error bars: Standard deviation of 3 experiments.
Figure 6 Batch equilibrium adsorption of 21 PFAS by IF -1. [PFAS] 0 = 1 μgL 1 each. Settled conventional water, OWASA, Chapel Hill, NC. Experiment time: 24 hours. Error bars: Standard deviation of 3 experiments.CC-BY-NC · From the PDF
Figure 7 Mini-Rapid Small-Scale column results of IF-8 (red traces) and IX (blue traces). IX = Purolite PFA694AE. [PFAS] 0 = 500 ngL 1 . Run time = 72 hours. Breakthrough = [PFAS]effluent /[PFAS]0 .
Figure 7 Mini-Rapid Small-Scale column results of IF-8 (red traces) and IX (blue traces). IX = Purolite PFA694AE. [PFAS] 0 = 500 ngL 1 . Run time = 72 hours. Breakthrough = [PFAS]effluent /[PFAS]0 .CC-BY-NC · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 60 references

Cited by

See all 32

Metadata

Authors
Manning, I. M., Guan Pin Chew, N., Macdonald, H. P., Miller, K. E., Strynar, M. J., Coronell, O., & Leibfarth, F. A.
Affiliations
  • University of North Carolina at Chapel Hill (US)
  • Department of Environmental Sciences and Engineering Gillings School of Global Public Health University of North Carolina at Chapel Hill 135 Dauer Dr Chapel Hill NC 27599 USA
  • Environmental Protection Agency (US)
Corresponding author
  • Coronell, Orlando
  • Leibfarth, Frank A.
Venue
Angewandte Chemie
Publisher
Wiley
Published
2022-09-02
Volume
134
Issue
41
ISSN
  • 0044-8249 (ISSN-L)
  • 1521-3757
OpenAlex
W4292458161
Cited by
31
References
60
Citations by year
2026: 5 · 2025: 19 · 2024: 6 · 2023: 1
FWCI
2.30
Type
journal article
Language
en
Open access
Locations
Angewandte Chemie (publishedVersion, cc-by-nc)
Funders
  • Strategic Environmental Research and Development Program (ER20-1211)
  • National Institute of Environmental Health Sciences (P42ES031007)
  • Directorate for Mathematical and Physical Sciences (CHE-1828183, CHE-0922858)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
Keywords
per- and polyfluoroalkyl substances, PFAS removal, water remediation, granular sorbents, emerging PFAS, legacy PFAS, short-chain PFAS, adsorbent regeneration, column experiments

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydrolytically Stable Ionic Fluorogels for High‐Performance Remediation of Per‐ and Polyfluoroalkyl Substances (PFAS) from Natural Water. https://app.cochat.ai/papers/10.1002/ange.202208150
The paper
Manning, I. M., Guan Pin Chew, N., Macdonald, H. P., Miller, K. E., Strynar, M. J., Coronell, O., & Leibfarth, F. A. (2022). Hydrolytically Stable Ionic Fluorogels for High‐Performance Remediation of Per‐ and Polyfluoroalkyl Substances (PFAS) from Natural Water. Angewandte Chemie. https://doi.org/10.1002/ange.202208150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.