The DOI matches its Crossref record.
Highly Sensitive MRI Chemical Exchange Saturation Transfer Agents Using Liposomes
Abstract
Contrasting views: Entrapment of a paramagnetic shift reagent for water protons inside liposomes dramatically improves the sensitivity of chemical exchange saturation transfer agents. The chemical shift of the water entrapped within the liposomes, relative to bulk water, depends upon the nature and concentration of the shift reagent as well as on the permeability of the liposome membrane (see picture; SR=shift reagent, Ln=lanthanide ion).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Inorganic Nanoparticles for MRI Contrast Agents
Na, H. B., Song, I. C., & Hyeon, T. (2009) · Advanced Materials · doi:10.1002/adma.200802366 · Cited by 1,781
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Challenges for Molecular Magnetic Resonance Imaging
Terreno, E., Castelli, D. D., Viale, A., & Aime, S. (2010) · Chemical Reviews · doi:10.1021/cr100025t · Cited by 855
Self-citationVillaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Lipid‐based nanoparticles for contrast‐enhanced MRI and molecular imaging
Mulder, W. J. M., Strijkers, G. J., van Tilborg, G. A. F., Griffioen, A. W., & Nicolay, K. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1011 · Cited by 535
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Alternatives to Gadolinium-Based Metal Chelates for Magnetic Resonance Imaging
Viswanathan, S., Kovacs, Z., Green, K. N., Ratnakar, S. J., & Sherry, A. D. (2010) · Chemical Reviews · doi:10.1021/cr900284a · Cited by 439
Paramagnetic lanthanide complexes as PARACEST agents for medical imaging
Woods, M., Woessner, D. E., & Sherry, A. D. (2006) · Chemical Society Reviews · doi:10.1039/b509907m · Cited by 393
Using lanthanide ions in molecular bioimaging
Amoroso, A. J., & Pope, S. J. A. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00293h · Cited by 391
Grüll, H., & Langereis, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.041 · Cited by 360
Chemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance Imaging
Sherry, A. D., & Woods, M. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151929 · Cited by 356
Aime, S., Castelli, D. D., Crich, S. G., Gianolio, E., & Terreno, E. (2009) · Accounts of Chemical Research · doi:10.1021/ar800192p · Cited by 350
Self-citationNuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
Metadata
- Authors
- Aime, S., Delli Castelli, D., & Terreno, E.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2005-08-22
- Volume
- 44
- Issue
- 34
- Pages
- 5513-5515
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2150548735
- Cited by
- 201
- References
- 0
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.