The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A Highly Selective Fluorescent Probe for Thiophenols
Abstract
A rapid response to thiophenols is obtained with probe 1 (see scheme), which induces a significant (>50-fold) fluorescence enhancement as a result of cleavage of the electron-withdrawing moiety, thus generating strongly fluorescent molecule 2. No fluorescence is obtained with aliphatic thiols, including cysteine and glutathione, or other nucleophiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new and rapid colorimetric determination of acetylcholinesterase activity
Ellman, G. L., Courtney, K. D., Andres, V., & Featherstone, R. M. (1961) · Biochemical Pharmacology · doi:10.1016/0006-2952(61)90145-9 · Cited by 27,126
Ellman, G. L. (1959) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(59)90090-6 · Cited by 26,311
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Ullmann's Encyclopedia of Industrial Chemistry
(2012) · Choice Reviews Online · doi:10.5860/choice.50-1224 · Cited by 3,049
Enzyme structure and mechanism
Elmore, D. T. (1978) · Endeavour · doi:10.1016/0160-9327(78)90081-9 · Cited by 2,710
Rettig, W. (1986) · Angewandte Chemie International Edition in English · doi:10.1002/anie.198609711 · Cited by 1,324
Facts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode
Shahrokhian, S. (2001) · Analytical Chemistry · doi:10.1021/ac010541m · Cited by 1,033
Handbook of fluorescent probes and research products
Haugland, R. P. (2002) · Cited by 1,032
Fluorescence of Organic Molecules in Chiral Recognition
Pu, L. (2004) · Chemical Reviews · doi:10.1021/cr030052h · Cited by 819
Detection of Homocysteine and Cysteine
Wang, W., Rusin, O., Xu, X., Kim, K. K., Escobedo, J. O., Fakayode, S. O., Fletcher, K. A., Lowry, M., Schowalter, C. M., Lawrence, C. M., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054962n · Cited by 593
Self-citationVisual Detection of Cysteine and Homocysteine
Rusin, O., St. Luce, N. N., Agbaria, R. A., Escobedo, J. O., Jiang, S., Warner, I. M., Dawan, F. B., Lian, K., & Strongin, R. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja036297t · Cited by 516
Rahman, I., & MacNee, W. (2000) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(00)00215-x · Cited by 489
Maeda, H., Matsuno, H., Ushida, M., Katayama, K., Saeki, K., & Itoh, N. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500114 · Cited by 396
7-chloro-4-nitrobenzo-2-oxa-1,3-diazole: a new fluorigenic reagent for amino acids and other amines
Ghosh, P. B., & Whitehouse, M. W. (1968) · Biochemical Journal · doi:10.1042/bj1080155 · Cited by 359
Ros-Lis, J. V., García, B., Jiménez, D., Martínez-Máñez, R., Sancenón, F., Soto, J., Gonzalvo, F., & Valldecabres, M. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031987i · Cited by 329
Analytical determination of homocysteine: a review
Nekrassova, O. (2003) · Talanta · doi:10.1016/s0039-9140(03)00173-5 · Cited by 310
Fukuyama, T., Cheung, M., Jow, C.-K., Hidai, Y., & Kan, T. (1997) · Tetrahedron Letters · doi:10.1016/s0040-4039(97)01334-8 · Cited by 289
Schwarzbauer, J., Heim, S., Brinker, S., & Littke, R. (2002) · Water Research · doi:10.1016/s0043-1354(01)00452-3 · Cited by 242
Tanaka, F., Mase, N., & Barbas III, C. F. (2004) · Chemical Communications · doi:10.1039/b405642f · Cited by 206
Direct Detection of Homocysteine
Wang, W., Escobedo, J. O., Lawrence, C. M., & Strongin, R. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0318838 · Cited by 198
Self-citationChen, S.-J., & Chang, H.-T. (2004) · Analytical Chemistry · doi:10.1021/ac049787s · Cited by 186
Fluorescence-based detection of thiols in vitro and in vivo using dithiol probes
Pullela, P. K., Chiku, T., Carvan, M. J., & Sem, D. S. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.047 · Cited by 158
Chow, C., Chiu, B. K.-W., Lam, M. H., & Wong, W. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034891x · Cited by 138
3′‐(2,4‐Dinitrobenzenesulfonyl)‐2′,7′‐dimethylfluorescein as a Fluorescent Probe for Selenols
Maeda, H., Katayama, K., Matsuno, H., & Uno, T. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200504299 · Cited by 127
Heparin-Induced Thrombocytopenia
Warkentin, T., & Kelton, J. G. (1989) · Annual Review of Medicine · doi:10.1146/annurev.me.40.020189.000335 · Cited by 113
Fluorescence probes for thiol-containing amino acids and peptides in aqueous solution
Fu, Y., Li, H., Hu, W., & Zhu, D. (2005) · Chemical Communications · doi:10.1039/b503772g · Cited by 89
Munday, R. (1985) · Journal of Applied Toxicology · doi:10.1002/jat.2550050613 · Cited by 75
Maeda, H., Matsuno, H., Ushida, M., Katayama, K., Saeki, K., & Itoh, N. (2005) · Angewandte Chemie · doi:10.1002/ange.200500114 · Cited by 70
Activation of monocrotaline, fulvine and their derivatives to toxic pyrroles by some thiols
Juneja, T. R., Gupta, R. L., & Samanta, S. (1984) · Toxicology Letters · doi:10.1016/0378-4274(84)90204-2 · Cited by 61
3′‐(2,4‐Dinitrobenzenesulfonyl)‐2′,7′‐dimethylfluorescein as a Fluorescent Probe for Selenols
Maeda, H., Katayama, K., Matsuno, H., & Uno, T. (2006) · Angewandte Chemie · doi:10.1002/ange.200504299 · Cited by 21
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
The triplet excited state of Bodipy: formation, modulation and application
Zhao, J., Xu, K., Yang, W., Wang, Z., & Zhong, F. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00364d · Cited by 867
Metadata
- Authors
- Jiang, W., Fu, Q., Fan, H., Ho, J., & Wang, W.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2007-11-02
- Volume
- 46
- Issue
- 44
- Pages
- 8445-8448
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2083255026
- Cited by
- 292
- References
- 34
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.