The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Addressing the PEG Mucoadhesivity Paradox to Engineer Nanoparticles that “Slip” through the Human Mucus Barrier
Open accessAbstract
Outsmarting the barrier: Conventional poly(ethylene glycol) (PEG) coated particles (green with light purple border) are immobilized in human mucus networks by adhesive interactions (red) with the mucus mesh (black lines). A dense, low molecular weight PEG coating (blue) uniquely endows nanoparticles with a mucoinert surface that enables their rapid mucus penetration (trajectory indicated by grey line).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mucus clearance as a primary innate defense mechanism for mammalian airways
Knowles, M. R., & Boucher, R. C. (2002) · Journal of Clinical Investigation · doi:10.1172/jci0215217 · Cited by 1,054
Rapid transport of large polymeric nanoparticles in fresh undiluted human mucus
Lai, S. K., O'Hanlon, D. E., Harrold, S., Man, S. T., Wang, Y.-Y., Cone, R., & Hanes, J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608611104 · Cited by 1,050
Self-citation
Cited by
PEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523
Self-citationBiomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Barua, S., & Mitragotri, S. (2014) · Nano Today · doi:10.1016/j.nantod.2014.04.008 · Cited by 1,257
Nanoparticles for direct nose-to-brain delivery of drugs
Mistry, A., Stolnik, S., & Illum, L. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.06.019 · Cited by 734
Adapting liposomes for oral drug delivery
He, H., Lu, Y., Qi, J., Zhu, Q., Chen, Z., & Wu, W. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2018.06.005 · Cited by 663
Metadata
- Authors
- Wang, Y., Lai, S. K., Suk, J. S., Pace, A., Cone, R., & Hanes, J.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2008-11-26
- Volume
- 47
- Issue
- 50
- Pages
- 9726-9729
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2154855352
- Cited by
- 597
- References
- 2
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Addressing the PEG Mucoadhesivity Paradox to Engineer Nanoparticles that “Slip” through the Human Mucus Barrier. https://app.cochat.ai/papers/10.1002/anie.200803526
- The paper
- Wang, Y., Lai, S. K., Suk, J. S., Pace, A., Cone, R., & Hanes, J. (2008). Addressing the PEG Mucoadhesivity Paradox to Engineer Nanoparticles that “Slip” through the Human Mucus Barrier. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.200803526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.