The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Rapid, Sensitive, and Quantitative Detection of Pathogenic DNA at the Point of Care through Microfluidic Electrochemical Quantitative Loop‐Mediated Isothermal Amplification
Open accessAbstract
Single-step DNA detection: a microfluidic electrochemical loop mediated isothermal amplification platform is reported for rapid, sensitive, and quantitative detection of pathogen genomic DNA at the point of care. DNA amplification was electrochemically monitored in real time within a monolithic microfluidic device, thus enabling the detection of as few as 16 copies of Salmonella genomic DNA through a single-step process in less than an hour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Mori, Y., Nagamine, K., Tomita, N., & Notomi, T. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5921 · Cited by 1,711
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Yang, S., & Rothman, R. E. (2004) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(04)01044-8 · Cited by 1,112
Real-time turbidimetry of LAMP reaction for quantifying template DNA
Mori, Y., Kitao, M., Tomita, N., & Notomi, T. (2004) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2003.12.005 · Cited by 627
Electrochemical DNA Hybridization Biosensors
Gooding, J. J. (2002) · Electroanalysis · doi:10.1002/1521-4109(200209)14:17<1149::aid-elan1149>3.0.co;2-8 · Cited by 480
Fang, X., Liu, Y., Kong, J., & Jiang, X. (2010) · Analytical Chemistry · doi:10.1021/ac1000652 · Cited by 292
Cited by
Wang, S., Zhang, L., Wan, S., Cansiz, S., Cui, C., Liu, Y., Cai, R., Hong, C., Teng, I.-T., Shi, M., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00373 · Cited by 476
Integrated Magneto–Electrochemical Sensor for Exosome Analysis
Jeong, S., Park, J., Pathania, D., Castro, C. M., Weissleder, R., & Lee, H. (2016) · ACS Nano · doi:10.1021/acsnano.5b07584 · Cited by 469
Reid, M. S., Le, X. C., & Zhang, H. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712217 · Cited by 338
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3114714 · Cited by 329
Metadata
- Authors
- Hsieh, K., Patterson, A. S., Ferguson, B. S., Plaxco, K. W., & Soh, H. T.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2012-04-04
- Volume
- 51
- Issue
- 20
- Pages
- 4896-4900
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2114940529
- Cited by
- 278
- References
- 21
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid, Sensitive, and Quantitative Detection of Pathogenic DNA at the Point of Care through Microfluidic Electrochemical Quantitative Loop‐Mediated Isothermal Amplification. https://app.cochat.ai/papers/10.1002/anie.201109115
- The paper
- Hsieh, K., Patterson, A. S., Ferguson, B. S., Plaxco, K. W., & Soh, H. T. (2012). Rapid, Sensitive, and Quantitative Detection of Pathogenic DNA at the Point of Care through Microfluidic Electrochemical Quantitative Loop‐Mediated Isothermal Amplification. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201109115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.