The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Ultrafluorogenic Coumarin–Tetrazine Probes for Real‐Time Biological Imaging
Open accessAbstract
We have developed a series of new ultrafluorogenic probes in the blue‐green region of the visible‐light spectrum that display fluorescence enhancement exceeding 11 000‐fold. These fluorogenic dyes integrate a coumarin fluorochrome with the bioorthogonal trans‐cyclooctene(TCO)–tetrazine chemistry platform. By exploiting highly efficient through‐bond energy transfer (TBET), these probes exhibit the highest brightness enhancements reported for any bioorthogonal fluorogenic dyes. No‐wash, fluorogenic imaging of diverse targets including cell‐surface receptors in cancer cells, mitochondria, and the actin cytoskeleton is possible within seconds, with minimal background signal and no appreciable nonspecific binding, opening the possibility for in vivo sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EGFR Antagonists in Cancer Treatment
Ciardiello, F., & Tortora, G. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0707704 · Cited by 2,058
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Jones, G., Jackson, W. R., Choi, C. Y., & Bergmark, W. R. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100248a024 · Cited by 1,174
Principles of Fluorescence Spectroscopy
Kumar Jain, M. (1984) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(84)90009-5 · Cited by 1,023
A Fluorogenic 1,3-Dipolar Cycloaddition Reaction of 3-Azidocoumarins and Acetylenes
Sivakumar, K., Xie, F., Cash, B. M., Long, S., Barnhill, H. N., & Wang, Q. (2004) · Organic Letters · doi:10.1021/ol047955x · Cited by 699
Bioorthogonal Turn‐On Probes for Imaging Small Molecules inside Living Cells
Devaraj, N. K., Hilderbrand, S., Upadhyay, R., Mazitschek, R., & Weissleder, R. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906120 · Cited by 457
Self-citationSpeiser, S. (1996) · Chemical Reviews · doi:10.1021/cr941193+ · Cited by 418
Functionalized Cyclopropenes As Bioorthogonal Chemical Reporters
Patterson, D. M., Nazarova, L. A., Xie, B., Kamber, D. N., & Prescher, J. A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3060436 · Cited by 370
Live‐Cell Imaging of Cyclopropene Tags with Fluorogenic Tetrazine Cycloadditions
Yang, J., Šečkutė, J., Cole, C. M., & Devaraj, N. K. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201202122 · Cited by 341
BODIPY–Tetrazine Derivatives as Superbright Bioorthogonal Turn‐on Probes
Carlson, J. C. T., Meimetis, L. G., Hilderbrand, S. A., & Weissleder, R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301100 · Cited by 334
Self-citationMinimal Tags for Rapid Dual‐Color Live‐Cell Labeling and Super‐Resolution Microscopy
Nikić, I., Plass, T., Schraidt, O., Szymański, J., Briggs, J. A. G., Schultz, C., & Lemke, E. A. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201309847 · Cited by 300
A fluorophore ligase for site-specific protein labeling inside living cells
Uttamapinant, C., White, K. A., Baruah, H., Thompson, S., Fernández-Suárez, M., Puthenveetil, S., & Ting, A. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914067107 · Cited by 292
Polarity-Sensitive Coumarins Tailored to Live Cell Imaging
Signore, G., Nifosì, R., Albertazzi, L., Storti, B., & Bizzarri, R. (2010) · Journal of the American Chemical Society · doi:10.1021/ja9050444 · Cited by 264
Single-cell and subcellular pharmacokinetic imaging allows insight into drug action in vivo
Thurber, G. M., Yang, K. S., Reiner, T., Kohler, R. H., Sorger, P., Mitchison, T., & Weissleder, R. (2013) · Nature Communications · doi:10.1038/ncomms2506 · Cited by 194
Self-citationFluorogenic Azidofluoresceins for Biological Imaging
Shieh, P., Hangauer, M. J., & Bertozzi, C. R. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308203h · Cited by 174
Cancer Cell Profiling by Barcoding Allows Multiplexed Protein Analysis in Fine-Needle Aspirates
Ullal, A. V., Peterson, V. M., Agasti, S. S., Tuang, S. L., Juric, D., Castro, C. M., & Weissleder, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3007361 · Cited by 154
Self-citationSynthesis of a Fluorogenic Cyclooctyne Activated by Cu-Free Click Chemistry
Jewett, J. C., & Bertozzi, C. R. (2011) · Organic Letters · doi:10.1021/ol2025026 · Cited by 113
Live‐Cell Imaging of Cyclopropene Tags with Fluorogenic Tetrazine Cycloadditions
Yang, J., Šečkutė, J., Cole, C. M., & Devaraj, N. K. (2012) · Angewandte Chemie · doi:10.1002/ange.201202122 · Cited by 104
Correlations of Structure and Rates of Energy Transfer for Through-Bond Energy-Transfer Cassettes
Kim, T. G., Castro, J. C., Loudet, A., Jiao, J. G.-S., Hochstrasser, R. M., Burgess, K., & Topp, M. R. (2005) · The Journal of Physical Chemistry A · doi:10.1021/jp053388z · Cited by 88
Hedberg, C., Dekker, F. J., Rusch, M., Renner, S., Wetzel, S., Vartak, N., Gerding‐Reimers, C., Bon, R. S., Bastiaens, P. I. H., & Waldmann, H. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201102965 · Cited by 80
Ascites analysis by a microfluidic chip allows tumor-cell profiling
Peterson, V. M., Castro, C. M., Chung, J., Miller, N. C., Ullal, A. V., Castano, M. D., Penson, R. T., Lee, H., Birrer, M. J., & Weissleder, R. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315370110 · Cited by 62
Self-citationSchnelle, zweifarbige Proteinmarkierung an lebenden Zellen für die hochauflösende Mikroskopie
Nikić, I., Plass, T., Schraidt, O., Szymański, J., Briggs, J. A. G., Schultz, C., & Lemke, E. A. (2014) · Angewandte Chemie · doi:10.1002/ange.201309847 · Cited by 51
Theisen, M., Linke, M., Kerbs, M., Fidder, H., Madjet, M. E., Zacarías, A. G., & Heyne, K. (2009) · The Journal of Chemical Physics · doi:10.1063/1.3236804 · Cited by 26
Hedberg, C., Dekker, F. J., Rusch, M., Renner, S., Wetzel, S., Vartak, N., Gerding‐Reimers, C., Bon, R. S., Bastiaens, P. I. H., & Waldmann, H. (2011) · Angewandte Chemie · doi:10.1002/ange.201102965 · Cited by 10
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Inverse electron demand Diels–Alder reactions in chemical biology
Oliveira, B. L., Guo, Z., & Bernardes, G. J. L. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00184c · Cited by 1,139
Scinto, S. L., Bilodeau, D. A., Hincapie, R., Lee, W., Nguyen, S. S., Xu, M., am Ende, C. W., Finn, M. G., Lang, K., Lin, Q., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00028-z · Cited by 592
Lo, K. K.-W. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00211 · Cited by 566
Biomedical applications of copper-free click chemistry: in vitro, in vivo, and ex vivo
Kim, E., & Koo, H. (2019) · Chemical Science · doi:10.1039/c9sc03368h · Cited by 421
Metadata
- Authors
- Meimetis, L. G., Carlson, J. C. T., Giedt, R. J., Kohler, R. H., & Weissleder, R.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2014-06-10
- Volume
- 53
- Issue
- 29
- Pages
- 7531-7534
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2148479920
- Cited by
- 253
- References
- 24
- FWCI
- 9.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.