The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Au@Pt Nanoparticle Encapsulated Target‐Responsive Hydrogel with Volumetric Bar‐Chart Chip Readout for Quantitative Point‐of‐Care Testing
Abstract
Point‐of‐care testing (POCT) with the advantages of speed, simplicity, portability, and low cost is critical for the measurement of analytes in a variety of environments where access to laboratory infrastructure is lacking. While qualitative POCTs are widely available, quantitative POCTs present significant challenges. Here we describe a novel method that integrates an Au core/Pt shell nanoparticle (Au@PtNP) encapsulated target‐responsive hydrogel with a volumetric bar‐chart chip (V‐Chip) for quantitative POCT. Upon target introduction, the hydrogel immediately dissolves and releases Au@PtNPs, which can efficiently catalyze the decomposition of H 2 O 2 to generate a large volume of O 2 to move of an ink bar in the V‐Chip. The concentration of the target introduced can be visually quantified by reading the traveling distance of the ink bar. This method has the potential to be used for portable and quantitative detection of a wide range of targets without any external instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04635 · Cited by 341
Song, P., Ye, D., Zuo, X., Li, J., Wang, J., Liu, H., Hwang, M. T., Chao, J., Su, S., Wang, L., et al. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b01006 · Cited by 258
Metadata
- Authors
- Zhu, Z., Guan, Z., Jia, S., Lei, Z., Lin, S., Zhang, H., Ma, Y., Tian, Z., & Yang, C. J.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2014-08-11
- Volume
- 53
- Issue
- 46
- Pages
- 12503-12507
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2142036107
- Cited by
- 303
- References
- 1
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Au@Pt Nanoparticle Encapsulated Target‐Responsive Hydrogel with Volumetric Bar‐Chart Chip Readout for Quantitative Point‐of‐Care Testing. https://app.cochat.ai/papers/10.1002/anie.201405995
- The paper
- Zhu, Z., Guan, Z., Jia, S., Lei, Z., Lin, S., Zhang, H., Ma, Y., Tian, Z., & Yang, C. J. (2014). Au@Pt Nanoparticle Encapsulated Target‐Responsive Hydrogel with Volumetric Bar‐Chart Chip Readout for Quantitative Point‐of‐Care Testing. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201405995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.