The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Au@Pt Nanoparticle Encapsulated Target‐Responsive Hydrogel with Volumetric Bar‐Chart Chip Readout for Quantitative Point‐of‐Care Testing
Abstract
Point‐of‐care testing (POCT) with the advantages of speed, simplicity, portability, and low cost is critical for the measurement of analytes in a variety of environments where access to laboratory infrastructure is lacking. While qualitative POCTs are widely available, quantitative POCTs present significant challenges. Here we describe a novel method that integrates an Au core/Pt shell nanoparticle (Au@PtNP) encapsulated target‐responsive hydrogel with a volumetric bar‐chart chip (V‐Chip) for quantitative POCT. Upon target introduction, the hydrogel immediately dissolves and releases Au@PtNPs, which can efficiently catalyze the decomposition of H 2 O 2 to generate a large volume of O 2 to move of an ink bar in the V‐Chip. The concentration of the target introduced can be visually quantified by reading the traveling distance of the ink bar. This method has the potential to be used for portable and quantitative detection of a wide range of targets without any external instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Liu, J., & Lu, Y. (2006) · Nature Protocols · doi:10.1038/nprot.2006.38 · Cited by 1,126
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Drivers of biodiagnostic development
Giljohann, D. A., & Mirkin, C. A. (2009) · Nature · doi:10.1038/nature08605 · Cited by 749
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Y., & Lu, Y. (2011) · Nature Chemistry · doi:10.1038/nchem.1092 · Cited by 677
Aptamers from Cell-Based Selection for Bioanalytical Applications
Tan, W., Donovan, M. J., & Jiang, J. (2013) · Chemical Reviews · doi:10.1021/cr300468w · Cited by 649
Autonomous Movement and Self-Assembly
Ismagilov, R. F., Schwartz, A., Bowden, N., & Whitesides, G. M. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020215)41:4<652::aid-anie652>3.0.co;2-u · Cited by 601
Requirements for high impact diagnostics in the developing world
Urdea, M., Penny, L. A., Olmsted, S. S., Giovanni, M. Y., Kaspar, P., Shepherd, A., Wilson, P., Dahl, C. A., Buchsbaum, S., Moeller, G., et al. (2006) · Nature · doi:10.1038/nature05448 · Cited by 594
Au@Pt nanostructures as oxidase and peroxidase mimetics for use in immunoassays
He, W., Liu, Y., Yuan, J., Yin, J.-J., Wu, X., Hu, X., Zhang, K., Liu, J., Chen, C., Ji, Y., et al. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.040 · Cited by 587
He, W., Zhou, Y.-T., Wamer, W. G., Hu, X., Wu, X., Zheng, Z., Boudreau, M. D., & Yin, J.-J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.10.010 · Cited by 416
An Aptamer Cross‐Linked Hydrogel as a Colorimetric Platform for Visual Detection
Zhu, Z., Wu, C., Liu, H., Zou, Y., Zhang, X., Kang, H., Yang, C. J., & Tan, W. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905570 · Cited by 364
Self-citationEngineering Target-Responsive Hydrogels Based on Aptamer−Target Interactions
Yang, H., Liu, H., Kang, H., & Tan, W. (2008) · Journal of the American Chemical Society · doi:10.1021/ja801339w · Cited by 363
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3114714 · Cited by 329
Self-citationMultiplexed volumetric bar-chart chip for point-of-care diagnostics
Song, Y., Zhang, Y., Bernard, P. E., Reuben, J. M., Ueno, N. T., Arlinghaus, R. B., Zu, Y., & Qin, L. (2012) · Nature Communications · doi:10.1038/ncomms2292 · Cited by 220
DNAzyme crosslinked hydrogel: a new platform for visual detection of metal ions
Lin, H., Zou, Y. W., Huang, Y., Chen, J., Zhang, W. Y., Zhuang, Z., Jenkins, G. N., & Yang, C. J. (2011) · Chemical Communications · doi:10.1039/c1cc12290h · Cited by 135
Self-citationBattig, M. R., Soontornworajit, B., & Wang, Y. (2012) · Journal of the American Chemical Society · doi:10.1021/ja305238a · Cited by 134
Li, J., Yang, Z., Ren, B. W., Liu, G., Fang, P., Jiang, Y., Wu, D., & Tian, Z. (2006) · Langmuir · doi:10.1021/la061366d · Cited by 123
Self-citationReaction Between Catalase and Hydrogen Peroxide
George, P. (1947) · Nature · doi:10.1038/160041a0 · Cited by 105
Lewis, G. G., Robbins, J. S., & Phillips, S. T. (2013) · Analytical Chemistry · doi:10.1021/ac402415v · Cited by 99
A Multistage Volumetric Bar Chart Chip for Visualized Quantification of DNA
Song, Y., Wang, Y., & Qin, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4085397 · Cited by 87
An Aptamer Cross‐Linked Hydrogel as a Colorimetric Platform for Visual Detection
Zhu, Z., Wu, C. S., Liu, H., Zou, Y. W., Zhang, X., Kang, H., Yang, C. J., & Tan, W. (2010) · Angewandte Chemie · doi:10.1002/ange.200905570 · Cited by 74
Self-citationUser-Loaded SlipChip for Equipment-Free Multiplexed Nanoliter-Scale Experiments
Li, L., Du, W., & Ismagilov, R. F. (2009) · Journal of the American Chemical Society · doi:10.1021/ja908555n · Cited by 73
Battig, M. R., Huang, Y., Chen, N., & Wang, Y. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.06.001 · Cited by 67
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Nanozymes: Classification, Catalytic Mechanisms, Activity Regulation, and Applications
Huang, Y., Ren, J., & Qu, X. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00672 · Cited by 3,523
Hydrogels for Biomedical Applications: Their Characteristics and the Mechanisms behind Them
Chai, Q., Jiao, Y., & Yu, X. (2017) · Gels · doi:10.3390/gels3010006 · Cited by 1,072
Nanozymes in bionanotechnology: from sensing to therapeutics and beyond
Wang, X., Hu, Y., & Wei, H. (2016) · Inorganic Chemistry Frontiers · doi:10.1039/c5qi00240k · Cited by 609
Metadata
- Authors
- Zhu, Z., Guan, Z., Jia, S., Lei, Z., Lin, S., Zhang, H., Ma, Y., Tian, Z., & Yang, C. J.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2014-08-11
- Volume
- 53
- Issue
- 46
- Pages
- 12503-12507
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2142036107
- Cited by
- 303
- References
- 28
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.