Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

NIR‐II pH Sensor with a FRET Adjustable Transition Point for In Situ Dynamic Tumor Microenvironment Visualization

Zhao, Mengyao, Wang, Jianbo, Lei, Zuhai, Lu, Lingfei, Wang, Shangfeng, Zhang, Hongxin, Li, Benhao, Zhang, Fan · 2021 · Angewandte Chemie International Edition

Abstract

Monitoring the pH in tumor lesions provides abundant physiological information. However, currently developed pH sensors only achieve sensitive detection in the settled response region around the pH transition point (pH t). To realize tumor pH monitoring with high sensitivity within a wider response region, reported here are serial pH t adjustable sensors (pTAS) that simply regulate the component ratio of second near‐infrared (NIR‐II) emission aza‐BODIPY (NAB) donor and pH sensitive rhodamine‐based pre‐acceptor (NRh) in Förster resonance energy transfer system. Combining the pH response regions of pTAS, a twofold widened pH detection range (6.11–7.22) is obtained compared to the pH t settled sensor (6.38–6.94). With an adjustable pH t, in vivo tumor pH increase and decrease processes could be dynamically visualized through dual‐channel ratiometric bioimaging within the NIR‐II window, with a coefficient of variation under 1 % compared to the standard pH meter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.202012021

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 160

Metadata

Authors
Zhao, M., Wang, J., Lei, Z., Lu, L., Wang, S., Zhang, H., Li, B., & Zhang, F.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2021-01-26
Volume
60
Issue
10
Pages
5091-5095
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W3111029008
Cited by
160
References
3
FWCI
8.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: NIR‐II pH Sensor with a FRET Adjustable Transition Point for In Situ Dynamic Tumor Microenvironment Visualization. https://app.cochat.ai/papers/10.1002/anie.202012021
The paper
Zhao, M., Wang, J., Lei, Z., Lu, L., Wang, S., Zhang, H., Li, B., & Zhang, F. (2021). NIR‐II pH Sensor with a FRET Adjustable Transition Point for In Situ Dynamic Tumor Microenvironment Visualization. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202012021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.