The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
NIR‐II pH Sensor with a FRET Adjustable Transition Point for In Situ Dynamic Tumor Microenvironment Visualization
Abstract
Monitoring the pH in tumor lesions provides abundant physiological information. However, currently developed pH sensors only achieve sensitive detection in the settled response region around the pH transition point (pH t). To realize tumor pH monitoring with high sensitivity within a wider response region, reported here are serial pH t adjustable sensors (pTAS) that simply regulate the component ratio of second near‐infrared (NIR‐II) emission aza‐BODIPY (NAB) donor and pH sensitive rhodamine‐based pre‐acceptor (NRh) in Förster resonance energy transfer system. Combining the pH response regions of pTAS, a twofold widened pH detection range (6.11–7.22) is obtained compared to the pH t settled sensor (6.38–6.94). With an adjustable pH t, in vivo tumor pH increase and decrease processes could be dynamically visualized through dual‐channel ratiometric bioimaging within the NIR‐II window, with a coefficient of variation under 1 % compared to the standard pH meter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vogelstein, B., Papadopoulos, N., Velculescu, V. E., Zhou, S., Diaz, L. A., & Kinzler, K. W. (2013) · Science · doi:10.1126/science.1235122 · Cited by 7,863
Maeda, H., Nakamura, H., & Fang, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.002 · Cited by 2,376
Li, H.-J., Du, J.-Z., Liu, J., Du, X.-J., Shen, S., Zhu, Y.-H., Wang, X., Ye, X., Nie, S., & Wang, J. (2016) · ACS Nano · doi:10.1021/acsnano.6b02326 · Cited by 537
Self-citation
Cited by
The Chemistry of Organic Contrast Agents in the NIR‐II Window
Mu, J., Xiao, M., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202114722 · Cited by 305
Cheng, H., Cao, X., Zhang, S., Zhang, K., Cheng, Y., Wang, J., Zhao, J., Zhou, L., Liang, X., & Yoon, J. (2023) · Advanced Materials · doi:10.1002/adma.202207546 · Cited by 260
Self-citationZhang, X., Chen, Y., He, H., Wang, S., Lei, Z., & Zhang, F. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202109728 · Cited by 176
Self-citationQin, Z., Ren, T., Zhou, H., Zhang, X., He, L., Li, Z., Zhang, X., & Yuan, L. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202201541 · Cited by 140
NIR‐II Organic Nanotheranostics for Precision Oncotherapy
Dai, H., Wang, X., Shao, J., Wang, W., Mou, X., & Dong, X. (2021) · Small · doi:10.1002/smll.202102646 · Cited by 110
Metadata
- Authors
- Zhao, M., Wang, J., Lei, Z., Lu, L., Wang, S., Zhang, H., Li, B., & Zhang, F.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2021-01-26
- Volume
- 60
- Issue
- 10
- Pages
- 5091-5095
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W3111029008
- Cited by
- 160
- References
- 3
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NIR‐II pH Sensor with a FRET Adjustable Transition Point for In Situ Dynamic Tumor Microenvironment Visualization. https://app.cochat.ai/papers/10.1002/anie.202012021
- The paper
- Zhao, M., Wang, J., Lei, Z., Lu, L., Wang, S., Zhang, H., Li, B., & Zhang, F. (2021). NIR‐II pH Sensor with a FRET Adjustable Transition Point for In Situ Dynamic Tumor Microenvironment Visualization. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202012021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.