The DOI matches its Crossref record; 100 of the 101 references it cites were found in a registry or an index.
Bright and Stable NIR‐II J‐Aggregated AIE Dibodipy‐Based Fluorescent Probe for Dynamic In Vivo Bioimaging
Abstract
Organic dyes emitting in the second near‐infrared (NIR‐II, 900–1700 nm) window, with high molar extinction coefficients (MEC) and quantum yields (QY) in aqueous, are essential for in vivo bioimaging and biosensing. In this work, we developed a dibodipy‐based aggregation‐induced emission (AIE) fluorescent probe, THPP, to meet this aim. THPP exhibits a high MEC and has intensified absorption and emission in J‐aggregated state, which significantly enhance the fluorescence intensity (≈55 folds) and extend the maximal absorption/emission wavelengths to 970/1010 nm in NIR‐II region. Based on the bright THPP, imaging with a high frame rate (34 frames per second) at a deep “valid penetration depth” up to 6 mm can be achieved. This enabled simultaneous and dynamic imaging of vasculatures and deep tissues. Besides, we succeeded in monitoring the respiratory rate of acute‐lung‐injury mice and tracing the collateral circulation process with a high frame rate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“An incorporation of the free rotating TPA groups led to a low Φfl in polar solvents due to the TICT effect.”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [152]
In the citing paper
“The restriction of the formation of its TICT state led to a 150-fold enhancement in Φfl in a nonpolar solvent.”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [152]
In the citing paper
“A fluorescent probe, THPP, based on the rigidified planar core structure of di-BODIPY, showed roughly an order of magnitude higher molar extinction coefficient than conventional D-A-D systems (Figure 7d).152”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [152]
In the citing paper
“The aggregation of the THPP molecules in water/THF mixtures revealed a further increase in Φfl that was accompanied by a shortened fluorescence lifetime, a strong red-shift of the fluorescence spectra (1006 nm), and a spectral narrowing (fwhm from 65 to 36 nm).”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [152]
In the citing paper
“Benefiting from an extended π-conjugation system of di-BODIPY, the absorption and emission wavelengths in polar solvents shifted to 900 and 920 nm, respectively.”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [152]
In the citing paper
“Worse still, D-A engineering leads to weak absorption in the long wavelengths20.”
From Alleviating NIR-II emission quenching in ring-fused fluorophore via manipulating dimer populations for superior fluorescence imaging (2025) · cites this paper as [20]
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 3,048
J‐Aggregates: From Serendipitous Discovery to Supramolecular Engineering of Functional Dye Materials
Würthner, F., Kaiser, T. E., & Saha‐Möller, C. R. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201002307 · Cited by 2,597
Cancer cell metabolism: warburg and beyond
Hsu, P. P., & Sabatini, D. M. (2008) · Cell · doi:10.1016/j.cell.2008.08.021 · Cited by 2,452
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R. E., Choyke, P. L., & Urano, Y. (2009) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,205
Bioprobes Based on AIE Fluorogens
Ding, D., Li, K., Liu, B., & Tang, B. Z. (2013) · Accounts of Chemical Research · doi:10.1021/ar3003464 · Cited by 1,835
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Rettig, W. (1986) · Angewandte Chemie International Edition in English · doi:10.1002/anie.198609711 · Cited by 1,328
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Semiconducting polymer nanoparticles as photoacoustic molecular imaging probes in living mice
Pu, K., Shuhendler, A. J., Jokerst, J. V., Mei, J., Gambhir, S. S., Bao, Z., & Rao, J. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.302 · Cited by 1,188
Research works printed but not linked: 1
- Xu W., 2020, Angew. Chem. Int. Ed.
Cited by
Sorted by citations
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 615
Self-citationLiu, Y., Li, Y., Koo, S., Sun, Y., Liu, Y., Liu, X., Pan, Y., Zhang, Z., Du, M., Lu, S., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00553 · Cited by 547
Self-citationThe Chemistry of Organic Contrast Agents in the NIR‐II Window
Mu, J., Xiao, M. W., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X. S. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202114722 · Cited by 322
NIR-II bioimaging of small organic molecule
Su, Y., Yu, B., Wang, S., Cong, H., & Shen, Y. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120717 · Cited by 251
Lee, K., Gao, Y., Wei, W., Tan, J., Wan, Y., Feng, Z., Zhang, Y., Liu, Y., Zheng, X., Cao, C., et al. (2023) · Advanced Materials · doi:10.1002/adma.202211632 · Cited by 182
Metadata
- Authors
- Zhang, Q., Yu, P., Fan, Y., Sun, C., He, H., Liu, X., Lu, L., Zhao, M., Zhang, H., & Zhang, F.
- Affiliations
- Fudan University (CN)
- Corresponding author
- Fan, Yong
- Zhang, Fan
- ORCID
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2020-12-23
- Volume
- 60
- Issue
- 8
- Pages
- 3967-3973
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W3088121390
- Cited by
- 216
- References
- 101
- Citations by year
- 2026: 22 · 2025: 38 · 2024: 33 · 2023: 34 · 2022: 55 · 2021: 32 · 2020: 1
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Angewandte Chemie International Edition (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (21725502, 51961145403, 21904023, 21908030)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- aggregation-induced emission, J-aggregation, second near-infrared window, in vivo imaging, deep tissue imaging, vascular imaging, acute lung injury, respiratory rate estimation, collateral circulation, ultrafast imaging, molar absorptivity
- MeSH terms
- Animals, Biocompatible Materials, Cerebral Veins, Fluorescent Dyes, Micelles, Propiophenones, Quantum Theory, Spectroscopy, Near-Infrared, Mice, Nanoparticles, Acute Lung Injury, Signal-To-Noise Ratio, Optical Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review