CoChat

A General Approach to Design Dual Ratiometric Fluorescent and Photoacoustic Probes for Quantitatively Visualizing Tumor Hypoxia Levels In Vivo

Zhang, Shuping, Chen, Hua, Wang, Liping, Qin, Xue, Jiang, Bang‐Ping, Ji, Shi‐Chen, Shen, Xing‐Can, Liang, Hong · 2022 · Angewandte Chemie International Edition
Cited by 139

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Herein, we describe an energy balance strategy between fluorescence and photoacoustic effects by sulfur substitution to transform existing hemicyanine dyes (Cy) into optimized NIRF/PA dual ratiometric scaffolds. Based on this optimized scaffold, we reported the first dual‐ratio response of nitroreductase probe AS‐Cy‐NO 2, which allows quantitative visualization of tumor hypoxia in vivo. AS‐Cy‐NO 2, composed of a new NIRF/PA scaffold thioxanthene‐hemicyanine (AS‐Cy‐1) and a 4‐nitrobenzene moiety, showed a 10‐fold ratiometric NIRF enhancement (I 773/I 733) and 2.4‐fold ratiometric PA enhancement (PA 730/PA 670) upon activation by a biomarker (nitroreductase, NTR) associated with tumor hypoxia. Moreover, the dual ratiometric NIRF/PA imaging accurately quantified the hypoxia extent with high sensitivity and high imaging depth in xenograft breast cancer models. More importantly, the 3D maximal intensity projection (MIP) PA images of the probe can precisely differentiate the highly heterogeneous oxygen distribution in solid tumor. Thus, this study provides a promising NIRF/PA scaffold that may be generalized for the dual ratiometric imaging of other disease‐relevant biomarkers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.202107076

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 139

Metadata

Authors
Zhang, S., Chen, H., Wang, L., Qin, X., Jiang, B., Ji, S., Shen, X., & Liang, H.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2021-12-27
Volume
61
Issue
7
Pages
e202107076-e202107076
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W3180760057
Cited by
139
References
5
FWCI
8.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A General Approach to Design Dual Ratiometric Fluorescent and Photoacoustic Probes for Quantitatively Visualizing Tumor Hypoxia Levels In Vivo. https://app.cochat.ai/papers/10.1002/anie.202107076
The paper
Zhang, S., Chen, H., Wang, L., Qin, X., Jiang, B., Ji, S., Shen, X., & Liang, H. (2022). A General Approach to Design Dual Ratiometric Fluorescent and Photoacoustic Probes for Quantitatively Visualizing Tumor Hypoxia Levels In Vivo. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202107076

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.