Cited by 20Molecular Sensors and Ion DetectionLuminescence and Fluorescent MaterialsNanoplatforms for cancer theranostics

Access to Diverse Activatable Heptamethine Cyanine Probes with Low Intrinsic Fluorescence via 5‐ exo‐trig Cyclization Strategy for High‐Contrast Bioimaging In Vivo

Wu, Fapu, Zheng, Bingbing, Qiu, Xinyu, Hu, Tao, Yang, Yuexia, Yang, Kairong, Zhou, Bijia, Ma, Qian +2 more·2025·Angewandte Chemie International Edition

Abstract

The conversion of conventional “always‐on” cyanine dyes into activatable NIR probes with low inherent fluorescence remains challenging, resulting in poor imaging contrast and nonspecific response in vivo. We herein report a 5‐ exo‐trig cyclization strategy to create diverse activatable heptamethine cyanine probes with “zero” intrinsic background fluorescence for high‐contrast bioimaging. This intramolecular ring‐closure approach imparts a built‐in switch to regulate the fluorescence of cyanine dyes, which predominantly exist in the nonfluorescent closed‐loop form at pH over 5.0 and are not affected by environmental polarity and protein interaction, thereby reducing false‐positive fluorescent signals. Upon reaction with various biomarkers, including methylglyoxal (MGO), hydroxyl radical (·OH), and adenosine triphosphate (ATP), they could rapidly transform into fluorescent open‐loop structures, showing significant NIR fluorescence enhancement (up to 184‐fold). Furthermore, we extended this strategy to develop a variety of NIR‐II ATP‐activatable cyanine probes for the first time, as well as a theranostic probe 57 using host–guest chemistry. Probe 57 not only sensitively monitored ATP levels in inflammatory bowel disease (IBD) with a high signal‐to‐background ratio of 48/1, but it also precisely detected extracellular ATP in stools. This work opens a new avenue to develop stimuli‐responsive NIR cyanine probes for improving disease diagnosis.

Integrity signals

Registry

Crossref · 10.1002/anie.202423059

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cy-57 achieved highly sensitive ATP monitoring in inflammatory bowel disease with an SBR of 48:1.

    “It achieved highly sensitive ATP monitoring in inflammatory bowel disease (IBD) with an SBR of 48:1.”
  • Upon activation by target biomarkers MGO, •OH, and ATP, these probes showed 109-137-fold fluorescence enhancement at 940 nm, yielding high SBRs of 28:1, 13:1, and 38:1, respectively.

    “Upon activation by the target biomarkers, including methylglyoxal (MGO), hydroxyl radicals (•OH), and adenosine triphosphate (ATP), these probes showed 109–137-fold fluorescence enhancement at 940 nm, yielding high SBRs of 28:1, 13:1, and 38:1, respectively.”
  • Xiong et al. engineered three activatable cyanine probes (Cy-29, Cy-30, and Cy-31) featuring diverse reactive groups.

    “Xiong et al. rationally engineered three activatable cyanine probes (Cy-29, Cy-30, and Cy-31) featuring diverse reactive groups (Fig. 15a)206.”
  • These activatable cyanine probes demonstrated excellent performance across multiple live models, highlighting significant potential for advancing disease diagnosis and multiplexed detection of biomarkers.

    “Collectively, these probes demonstrated excellent performance across multiple live models, highlighting their significant potential for advancing disease diagnosis and multiplexed detection of biomarkers in complex biological environments.”
  • Leveraging host-guest chemistry, researchers developed a dual-responsive NIR-II theranostic probe Cy-57 capable of simultaneous sensing of ATP and ROS.

    “Furthermore, leveraging host-guest chemistry, the researchers developed a dual-responsive NIR-II theranostic probe (Cy-57) capable of simultaneous sensing of ATP and ROS.”

Cites

Flagged first, then by citations

1 of the 56 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Wu, F., Zheng, B., Qiu, X., Hu, T., Yang, Y., Yang, K., Zhou, B., Ma, Q., Pang, D., & Xiong, H.
Affiliations
  • Nankai University (CN)
  • Research Center for Analytical Sciences Tianjin Key Laboratory of Biosensing and Molecular Recognition Frontiers Science Center for New Organic Matter College of Chemistry Nankai University 94 Weijin Road, Nankai District Tianjin 300071 China
Corresponding author
Xiong, Hu
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2025-06-02
Volume
64
Issue
31
Pages
e202423059-e202423059
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W4410832237
Cited by
18
References
56
Citations by year
2026: 12 · 2025: 6
FWCI
4.56
Type
journal article
Language
en
Open access
closed
Locations
  • Angewandte Chemie International Edition (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (22422407, 22174078)
  • Fundamental Research Funds for the Central Universities (020–63253156)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
Keywords
heptamethine cyanine dyes, activatable fluorescent probes, 5-exo-trig cyclization, intramolecular ring closure, NIR-II fluorescence, host-guest chemistry, theranostic probes, inflammatory bowel disease, hydroxyl radical detection
MeSH terms
Adenosine Triphosphate, Animals, Carbocyanines, Cyclization, Fluorescence, Fluorescent Dyes, Humans, Molecular Structure, Mice, Optical Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review