Synthesis of unsaturated polyphosphoester as a potential injectable tissue engineering scaffold materials
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Polyphosphoester is a kind of biodegradable polymer with excellent biocompatibility and have been used in drug delivery, tissue engineering, and other bioapplications. A novel unsaturated polyphosphoester (UPPE) based on bis(1,2‐propylene glycol) fumarate (BPGF) and ethyl dichlorophosphate was synthesized by polycondensation reaction, and crosslinkable double bonds was introduced into the resulting polymer through the fumarate groups. NMR results indicate that there are three possible bonding models in polyphosphoester because of three isomers of BPGF. The GPC results express that increase in polymerization time leads to high molecular weight of polyphosphester and narrow distribution of molecular weight. After 18 h of polymerization reaction, the molecular weight reached to 5956 g mol−1 and the polydispersity index was 1.12. The UPPE was soluble in N‐vinyl pyrrolidone and easily crosslinked by free‐radical polymerization. At the constant temperature (37°C), the maximum temperature due to heat release during crosslinking reaction varied from 41.1°C to 82.30°C and the setting time was between 1.95 and 10.28 min, according to different formulas. © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 102: 3095–3101, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Injectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554
Kumar, N., Langer, R. S., & Domb, A. J. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00050-9 · Cited by 394
A review of photocrosslinked polyanhydrides:
Burkoth, A. K., & Anseth, K. S. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00107-1 · Cited by 191
Cited by
Biodegradable synthetic polymers: Preparation, functionalization and biomedical application
Tian, H., Tang, Z., Zhuang, X., Chen, X., & Jing, X. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.004 · Cited by 1,293
Polymer carriers for drug delivery in tissue engineering
Sokolsky-Papkov, M., Agashi, K., Olaye, A., Shakesheff, K., & Domb, A. J. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.001 · Cited by 452
Phosphorus-Containing Polymers: A Great Opportunity for the Biomedical Field
Monge, S., Canniccioni, B., Graillot, A., & Robin, J.-J. (2011) · Biomacromolecules · doi:10.1021/bm2004803 · Cited by 317
Recent progress in polyphosphoesters: From controlled synthesis to biomedical applications
Wang, Y., Yuan, Y., Du, J., Yang, X., & Wang, J. (2009) · Macromolecular Bioscience · doi:10.1002/mabi.200900253 · Cited by 203
Bauer, K. N., Tee, H. T., Velencoso, M. M., & Wurm, F. R. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.05.004 · Cited by 189
Metadata
- Authors
- Qiu, J., Liu, C., Hu, F., Guo, X., & Zheng, Q.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2006-08-29
- Volume
- 102
- Issue
- 4
- Pages
- 3095-3101
- ISSN
- 0021-8995 (ISSN-L)
- 1097-4628
- OpenAlex
- W2056552959
- Cited by
- 26
- References
- 3
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.