Photopatterning of hydrogel scaffolds coupled to filter materials using stereolithography for perfused 3D culture of hepatocytes
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In vitro models that recapitulate the liver's structural and functional complexity could prolong hepatocellular viability and function to improve platforms for drug toxicity studies and understanding liver pathophysiology. Here, stereolithography (SLA) was employed to fabricate hydrogel scaffolds with open channels designed for post‐seeding and perfused culture of primary hepatocytes that form 3D structures in a bioreactor. Photopolymerizable polyethylene glycol‐based hydrogels were fabricated coupled to chemically activated, commercially available filters (polycarbonate and polyvinylidene fluoride) using a chemistry that permitted cell viability, and was robust enough to withstand perfused culture of up to 1 µL/s for at least 7 days. SLA energy dose, photoinitiator concentrations, and pretreatment conditions were screened to determine conditions that maximized cell viability and hydrogel bonding to the filter. Multiple open channel geometries were readily achieved, and included ellipses and rectangles. Rectangular open channels employed for subsequent studies had final dimensions on the order of 350 µm by 850 µm. Cell seeding densities and flow rates that promoted cell viability were determined. Perfused culture of primary hepatocytes in hydrogel scaffolds in the presence of soluble epidermal growth factor (EGF) prolonged the maintenance of albumin production throughout the 7‐day culture relative to 2D controls. This technique of bonding hydrogel scaffolds can be employed to fabricate soft scaffolds for a number of bioreactor configurations and applications. Biotechnol. Bioeng. 2015;112: 777–787. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280 · cited 3×
“Most hepatocellular functions such as albumin secretion and drug metabolism decline rapidly when hepatocytes are isolated from liver and maintained in standard monolayer culture, but static culture formats that drive 3D hepatocyte aggregation into spheroids or polarization within extracellular matrix (ECM) gels can pr…”
BackgroundOrganotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234 · cited 8×
“However, because hepatocytes are highly metabolically active – typically residing in close contact with blood through the fenestrated endothelium – controlling mass transfer of nutrients, substrates, and metabolites in 3D aggregates in static culture is challenging [Powers et al., 2002a].”
BackgroundMethodResultInfluentialSelf-citationA gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172 · cited 2×
“The production rates in this system translate to ~35 to 42 pg/cell/day, which falls within the range of albumin secretion rates reported for a variety of reactor configurations ranging from 2 to upwards of 150 pg/cell/day (Ong et al., 2008; Powers et al., 2002b; Tsang et al., 2007).”
Background
Cited by
Multivascular networks and functional intravascular topologies within biocompatible hydrogels
Grigoryan, B., Paulsen, S. J., Corbett, D. C., Sazer, D. W., Fortin, C. L., Zaita, A. J., Greenfield, P. T., Calafat, N. J., Gounley, J. P., Ta, A. H., et al. (2019) · Science · doi:10.1126/science.aav9750 · Cited by 1,396
Deterministically patterned biomimetic human iPSC-derived hepatic model via rapid 3D bioprinting
Ma, X., Qu, X., Zhu, W., Li, Y.-S., Yuan, S., Zhang, H., Liu, J., Wang, P., Lai, C. S. E., Zanella, F., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1524510113 · Cited by 872
‘Printability' of Candidate Biomaterials for Extrusion Based 3D Printing: State‐of‐the‐Art
Kyle, S., Jessop, Z. M., Al‐Sabah, A., & Whitaker, I. S. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700264 · Cited by 495
Mondschein, R. J., Kanitkar, A., Williams, C. B., Verbridge, S. S., & Long, T. E. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.005 · Cited by 475
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Metadata
- Authors
- Neiman, J. A. S., Raman, R., Chan, V., Rhoads, M. G., Raredon, M. S. B., Velazquez, J. J., Dyer, R. L., Bashir, R., Hammond, P. T., & Griffith, L. G.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2015-02-23
- Volume
- 112
- Issue
- 4
- Pages
- 777-787
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2115330640
- Cited by
- 78
- References
- 4
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photopatterning of hydrogel scaffolds coupled to filter materials using stereolithography for perfused 3D culture of hepatocytes. https://app.cochat.ai/papers/10.1002/bit.25494
- The paper
- Neiman, J. A. S., Raman, R., Chan, V., Rhoads, M. G., Raredon, M. S. B., Velazquez, J. J., Dyer, R. L., Bashir, R., Hammond, P. T., & Griffith, L. G. (2015). Photopatterning of hydrogel scaffolds coupled to filter materials using stereolithography for perfused 3D culture of hepatocytes. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.25494
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.