CoChat

Oxygen is a factor determining in vitro tissue assembly: Effects on attachment and spreading of hepatocytes

Rotem, Avi, Toner, Mehmet, Bhatia, Sangeeta, Foy, Brent D., Tompkins, Ronald G., Yarmush, Martin L. · 1994 · Biotechnology and Bioengineering
Cited by 94

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Many recent studies related to the development of bioartificial liver devices have utilized hepatocytes cultured within devices of various geometries. Because hepatocytes are anchorage‐dependent cells, they need to attach and spread onto the extracellular matrix to be able to function, a process that requires energy. Thus, it is important to deliver enough oxygen to hepatocytes contained within bioartificial liver devices during the early phase of cellular organization while the cells interact with the extracellular matrix. In this study, we investigated the effect of oxygen on the attachment and spreading of hepatocytes. Increasing the gas phase oxygen from 0 to 160 mmHg resulted in an increase in the percentage of cells attaching from 43.0 ± 5.8% to 103.6 ± 29%, 1 h after seeding. In a similar manner, increasing the gas phase oxygen from 0 to 160 mmHg resulted in an increase of the projected surface area from 310 ± 35 to 827 ± 127 μm 2, 24 h after seeding. Furthermore, the partial pressure of oxygen at the cell level was estimated using a diffusion‐reaction model. The model indicated that a cell surface oxygen partial pressure of 0.064 mmHg was required for the half‐maximal (K) attachment of hepatocytes to collagen‐based substrate. On the other hand, the K value of the spreading process was predicted to be 0.13 mmHg. The results of this study demonstrate the importance of oxygen during the initial stages of attachment and spreading of hepatocytes, and it has important implications in the design of hepatocyte‐based bioartificial liver devices. © 1994 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.260430715

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 94

Metadata

Authors
Rotem, A., Toner, M., Bhatia, S., Foy, B. D., Tompkins, R. G., & Yarmush, M. L.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
1994-03-25
Volume
43
Issue
7
Pages
654-660
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2147002266
Cited by
94
References
1
FWCI
2.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen is a factor determining in vitro tissue assembly: Effects on attachment and spreading of hepatocytes. https://app.cochat.ai/papers/10.1002/bit.260430715
The paper
Rotem, A., Toner, M., Bhatia, S., Foy, B. D., Tompkins, R. G., & Yarmush, M. L. (1994). Oxygen is a factor determining in vitro tissue assembly: Effects on attachment and spreading of hepatocytes. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260430715

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.