The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Extraction of Proteins from Biological Fluids by Use of an Ionic Liquid/Aqueous Two‐Phase System
Abstract
An ionic liquid/aqueous two‐phase system based on the hydrophilic ionic liquid 1‐butyl‐3‐methylimidazolium chloride (BmimCl) and K 2 HPO 4 has been employed for direct extraction of proteins from human body fluids for the first time. Proteins present at low levels were quantitatively extracted into the BmimCl‐rich upper phase with a distribution ratio of about 10 between the upper and lower phase and an enrichment factor of 5. Addition of an appropriate amount of K 2 HPO 4 to the separated upper phase results in a further phase separation, giving rise to an improved enrichment factor of 20. FTIR and UV spectroscopy demonstrated that no chemical (bonding) interactions between the ionic liquid and the protein functional groups were identifiable, while no alterations of the natural properties of the proteins were observed. The partitioning of proteins in the two‐phase system was assumed to have been facilitated by the electrostatic potential difference between the coexisting phases, as well as by salting out effects. The system could be applied successfully for the quantification of proteins in human urine after on‐line phase separation in a flow system. The use of an ionic liquid, as a green solvent, offers clear advantages over traditional liquid–liquid extractions, in which the use of toxic organic solvents is unavoidable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Cited by
Aqueous biphasic systems: a boost brought about by using ionic liquids
Freire, M. G., Cláudio, A. F. M., Araújo, J. M. M., Coutinho, J. A. P., Marrucho, I. M., Lopes, J. N. C., & Rebelo, L. P. N. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35151j · Cited by 817
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Ionic Liquids in Chemical Engineering
Werner, S., Haumann, M., & Wasserscheid, P. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100915 · Cited by 373
Ionic liquid/water mixtures: from hostility to conciliation
Kohno, Y., & Ohno, H. (2012) · Chemical Communications · doi:10.1039/c2cc31638b · Cited by 366
Revisiting the Physicochemical Properties and Applications of Deep Eutectic Solvents
Ijardar, S. P., Singh, V., & Gardas, R. L. (2022) · Molecules · doi:10.3390/molecules27041368 · Cited by 363
Metadata
- Authors
- Du, Z., Yu, Y., & Wang, J.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2007-02-08
- Volume
- 13
- Issue
- 7
- Pages
- 2130-2137
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2144359296
- Cited by
- 319
- References
- 1
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extraction of Proteins from Biological Fluids by Use of an Ionic Liquid/Aqueous Two‐Phase System. https://app.cochat.ai/papers/10.1002/chem.200601234
- The paper
- Du, Z., Yu, Y., & Wang, J. (2007). Extraction of Proteins from Biological Fluids by Use of an Ionic Liquid/Aqueous Two‐Phase System. Chemistry – A European Journal. https://doi.org/10.1002/chem.200601234
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.