The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Dual Amino‐Functionalised Phosphonium Ionic Liquids for CO2 Capture
Open accessAbstract
CO2 is locked up: Dual amino‐functionalised phosphonium ionic liquids (ILs; see figure) have been prepared. The ILs have excellent thermal properties, such as low glass transition temperatures and high thermal decomposition temperatures. The supported CO 2 absorption of four of the ILs on porous SiO 2 was found to approach one mol CO 2 per mol IL, a factor of two greater than that reported before.magnified image A series of 20 dual amino‐functionalised phosphonium ionic liquids, (3‐aminopropyl)tributylphosphonium amino acid salts ([aP 4443][AA], in which [AA]−=[Ala]−, [Arg]−, [Asn]−, [Asp]−, [Cys]−, [Gln]−, [Glu]−, [Gly]−, [His]−, [Ile]−, [Leu]−, [Lys]−, [Met]−, [Phe]−, [Pro]−, [Ser]−, [Thr]−, [Trp]−, [Tyr]− and [Val]−), has been prepared. Their physicochemical properties, such as density, viscosity, glass transition and thermal decomposition temperatures and conductivity, have been determined. In particular, the [aP 4443][AA] ionic liquids (ILs) have low glass transition temperatures ranging from −69.7 to −29.6 °C and high decomposition temperatures (all above 200 °C). The effects of the variation of the structure of [AA]− on the above physicochemical properties are discussed. Furthermore, the CO 2 absorption of [aP 4443][Gly], [aP 4443][Ala], [aP 4443][Val] and [aP 4443][Leu], taken as examples, was investigated. It was found that the supported absorption of CO 2 by the [aP 4443][AA] ILs almost reaches equilibrium within 80 min, the chemical absorption of CO 2 by the [aP 4443][AA] ILs approaches 1 mol CO 2 per mol ionic liquid (twice that reported before) and the [aP 4443][AA] ILs can be repeatedly recycled for CO 2 uptake.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrophobic, Highly Conductive Ambient-Temperature Molten Salts
Bonhôte, P., Dias, A.-P., Papageorgiou, N., Kalyanasundaram, K., & Grätzel, M. (1996) · Inorganic Chemistry · doi:10.1021/ic951325x · Cited by 4,358
Ionic Liquids--Solvents of the Future?
Rogers, R. D., & Seddon, K. R. (2003) · Science · doi:10.1126/science.1090313 · Cited by 4,130
Huddleston, J. G., Visser, A. E., Reichert, W. M., Willauer, H. D., Broker, G. A., & Rogers, R. D. (2001) · Green Chemistry · doi:10.1039/b103275p · Cited by 3,712
CO2 Capture by a Task-Specific Ionic Liquid
Bates, E. D., Mayton, R. D., Ntai, I., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017593d · Cited by 2,270
Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction
Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D. (1998) · Chem. Commun. · doi:10.1039/a803999b · Cited by 2,167
Ionic Liquids for Clean Technology
Seddon, K. R. (1997) · Journal of Chemical Technology & Biotechnology · doi:10.1002/(sici)1097-4660(199704)68:4<351::aid-jctb613>3.0.co;2-4 · Cited by 2,034
Why Is CO2 So Soluble in Imidazolium-Based Ionic Liquids?
Cadena, C., Anthony, J. L., Shah, J. K., Morrow, T. I., Brennecke, J. F., & Maginn, E. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039615x · Cited by 1,518
Room Temperature Ionic Liquids from 20 Natural Amino Acids
Fukumoto, K., Yoshizawa, M., & Ohno, H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043451i · Cited by 1,236
Holbrey, J. D., & Seddon, K. R. (1999) · Journal of the Chemical Society, Dalton Transactions · doi:10.1039/a902818h · Cited by 1,230
Anion Effects on Gas Solubility in Ionic Liquids
Anthony, J. L., Anderson, J. L., Maginn, E. J., & Brennecke, J. F. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp046404l · Cited by 1,058
Cited by
Carbon capture and storage (CCS): the way forward
Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., Fennell, P. S., Fuss, S., Galindo, A., Hackett, L. A., et al. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02342a · Cited by 4,374
Carbon capture and storage update
Boot-Handford, M. E., Abanades, J. C., Anthony, E. J., Blunt, M. J., Brandani, S., Mac Dowell, N., Fernández, J. R., Ferrari, M.-C., Gross, R., Hallett, J. P., et al. (2014) · Energy Environ. Sci. · doi:10.1039/c3ee42350f · Cited by 2,386
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
“To enhance CO 2 capture capacity of IL, Zhang et al. (2009b) proposed to use the supported ILs.”
Ionic-Liquid-Based CO2 Capture Systems: Structure, Interaction and Process
Zeng, S., Zhang, X., Bai, L., Zhang, X., Wang, H., Wang, J., Bao, D., Li, M., Liu, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00072 · Cited by 1,000
Self-citationEfficient, selective and sustainable catalysis of carbon dioxide
Song, Q.-W., Zhou, Z.-H., & He, L.-N. (2017) · Green Chemistry · doi:10.1039/c7gc00199a · Cited by 980
Carbon capture with ionic liquids: overview and progress
Zhang, X., Zhang, X., Dong, H., Zhao, Z., Zhang, S., & Huang, Y. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21152a · Cited by 863
Self-citationIonic Liquids-Based Extraction: A Promising Strategy for the Advanced Nuclear Fuel Cycle
Sun, X., Luo, H., & Dai, S. (2012) · Chemical Reviews · doi:10.1021/cr200193x · Cited by 852
Natural gas origin, composition, and processing: A review
Faramawy, S., Zaki, T., & Sakr, A. A.-E. (2016) · Journal of Natural Gas Science and Engineering · doi:10.1016/j.jngse.2016.06.030 · Cited by 788
Review of recent advances in carbon dioxide separation and capture
Kenarsari, S. D., Yang, D., Jiang, G., Zhang, S., Wang, J., Russell, A. G., Wei, Q., & Fan, M. (2013) · RSC Advances · doi:10.1039/c3ra43965h · Cited by 784
Self-citationMultiscale Studies on Ionic Liquids
Dong, K., Liu, X., Dong, H., Zhang, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00776 · Cited by 773
Self-citationGiernoth, R. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905981 · Cited by 746
Tuning the Basicity of Ionic Liquids for Equimolar CO2 Capture
Wang, C., Luo, X., Luo, H., Jiang, D., Li, H., & Dai, S. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201008151 · Cited by 691
Rufford, T. E., Smart, S., Watson, G. C. Y., Graham, B. F., Boxall, J., Diniz da Costa, J. C., & May, E. F. (2012) · Journal of Petroleum Science and Engineering · doi:10.1016/j.petrol.2012.06.016 · Cited by 676
Are Ionic Liquids Chemically Stable?
Wang, B., Qin, L., Mu, T., Xue, Z., & Gao, G. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00594 · Cited by 665
A systematic review on CO2 capture with ionic liquids: Current status and future prospects
Aghaie, M., Rezaei, N., & Zendehboudi, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.07.004 · Cited by 594
Carbon dioxide utilization with C–N bond formation: carbon dioxide capture and subsequent conversion
Yang, Z.-Z., He, L.-N., Gao, J., Liu, A.-H., & Yu, B. (2012) · Energy & Environmental Science · doi:10.1039/c2ee02774g · Cited by 520
Carbon Dioxide Capture by Superbase‐Derived Protic Ionic Liquids
Wang, C., Luo, H., Jiang, D., Li, H., & Dai, S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201002641 · Cited by 516
Ionic liquids for energy, materials, and medicine
Smiglak, M., Pringle, J. M., Lu, X., Han, L., Zhang, S., Gao, H., MacFarlane, D. R., & Rogers, R. D. (2014) · Chem. Commun. · doi:10.1039/c4cc02021a · Cited by 509
Self-citationActive chemisorption sites in functionalized ionic liquids for carbon capture
Cui, G., Wang, J., & Zhang, S. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00462d · Cited by 498
Self-citationLi, L., Zhao, N., Wei, W., & Sun, Y. (2013) · Fuel · doi:10.1016/j.fuel.2011.08.022 · Cited by 480
Molecular Design of High Capacity, Low Viscosity, Chemically Tunable Ionic Liquids for CO2 Capture
Gurkan, B., Goodrich, B. F., Mindrup, E. M., Ficke, L. E., Massel, M., Seo, S., Senftle, T. P., Wu, H., Glaser, M. F., Shah, J. K., et al. (2010) · The Journal of Physical Chemistry Letters · doi:10.1021/jz101533k · Cited by 454
Ionic liquid-based materials: a platform to design engineered CO2 separation membranes
Tomé, L. C., & Marrucho, I. M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00510h · Cited by 430
Carbon Dioxide Capture with Ionic Liquids and Deep Eutectic Solvents: A New Generation of Sorbents
Sarmad, S., Mikkola, J., & Ji, X. (2017) · ChemSusChem · doi:10.1002/cssc.201600987 · Cited by 406
CO2 chemistry: task-specific ionic liquids for CO2 capture/activation and subsequent conversion
Yang, Z.-Z., Zhao, Y.-N., & He, L.-N. (2011) · RSC Advances · doi:10.1039/c1ra00307k · Cited by 393
Multi‐Molar Absorption of CO2 by the Activation of Carboxylate Groups in Amino Acid Ionic Liquids
Chen, F., Huang, K., Zhou, Y., Tian, Z., Zhu, X., Tao, D., Jiang, D., & Dai, S. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602919 · Cited by 351
Experimental Measurements of Amine-Functionalized Anion-Tethered Ionic Liquids with Carbon Dioxide
Goodrich, B. F., de la Fuente, J. C., Gurkan, B. E., Zadigian, D. J., Price, E. A., Huang, Y., & Brennecke, J. F. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie101688a · Cited by 305
Energy Applications of Ionic Liquids: Recent Developments and Future Prospects
Zhou, T., Gui, C., Sun, L., Hu, Y., Lyu, H., Wang, Z., Song, Z., & Yu, G. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00391 · Cited by 305
Advancements in carbon capture technologies: A review
Dubey, A., & Arora, A. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.133932 · Cited by 303
Deep eutectic solvents as attractive media for CO2 capture
Trivedi, T. J., Lee, J. H., Lee, H. J., Jeong, Y. K., & Choi, J. W. (2016) · Green Chemistry · doi:10.1039/c5gc02319j · Cited by 299
Goodrich, B. F., de la Fuente, J. C., Gurkan, B. E., Lopez, Z. K., Price, E. A., Huang, Y., & Brennecke, J. F. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp2015534 · Cited by 272
CO2 Capture from Dilute Gases as a Component of Modern Global Carbon Management
Jones, C. W. (2011) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-061010-114252 · Cited by 268
Are ionic liquids a proper solution to current environmental challenges?
Cevasco, G., & Chiappe, C. (2014) · Green Chemistry · doi:10.1039/c3gc42096e · Cited by 267
Chemically Tunable Ionic Liquids with Aprotic Heterocyclic Anion (AHA) for CO2 Capture
Seo, S., Quiroz-Guzman, M., DeSilva, M. A., Lee, T. B., Huang, Y., Goodrich, B. F., Schneider, W. F., & Brennecke, J. F. (2014) · The Journal of Physical Chemistry B · doi:10.1021/jp502279w · Cited by 265
Metadata
- Authors
- Zhang, Y., Zhang, S., Lu, X., Zhou, Q., Fan, W., & Zhang, X.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2009-02-26
- Volume
- 15
- Issue
- 12
- Pages
- 3003-3011
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2014752811
- Cited by
- 436
- References
- 25
- FWCI
- 10.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.