A correlation for gas holdup in turbulent coalescing bubble columns
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A review of existing literature for the purpose of comparing correlations which allow the explicit predictiosn of gas holdup in two‐ or three‐phase bubble columns shows wide disagreement concerning the effect of various variables. Further, various correlations, apparently of equal validity, show equally wide disagreement in the predicted absolute values of gas holdup among three test systems; water‐air, hydrocarbon solvent—air, and trichloroethytene air. Some possible reasons for these disagreements are discussed. Extensive gas holdup data obtained in a 0.30 m diameter column for the three test systems were correlated statistically for the transition and the turbulent region. The resulting correlation gives agreement with experiment to within ±20%, with most data showing ± 10% agreement. The proposed correlation was also tested against thirteen data sets (from eight researchers) which corresponded to its region of validity and gave good agreement. Three additional relevant data sets were not satisfactorily predicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design parameters estimations for bubble column reactors
Shah, Y. T., Kelkar, B. G., Godbole, S. P., & Deckwer, W. ‐. (1982) · AIChE Journal · doi:10.1002/aic.690280302 · Cited by 1,202
Gas Holdup and Volumetric Mass Transfer Coefficient in Bubble Columns. Effects of Liquid Properties
Akita, K., & Yoshida, F. (1973) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260045a015 · Cited by 684
Cited by
Kantarci, N., Borak, F., & Ulgen, K. O. (2005) · Process Biochemistry · doi:10.1016/j.procbio.2004.10.004 · Cited by 1,057
“The most widely used technique in estimating gas holdup is the pressure profile method which is based on measuring the static pressure at two or more points along the column using manometers or more recently pressure transducers and thus obtaining the pressure drop, DP, along the bed [56,59,61,62].”
BackgroundMethodDesign parameters estimation for scale‐up of high‐pressure bubble columns
Wilkinson, P. M., Spek, A. P., & van Dierendonck, L. L. (1992) · AIChE Journal · doi:10.1002/aic.690380408 · Cited by 393
Improved tools for bubble column reactor design and scale-up
Deckwer, W.-D., & Schumpe, A. (1993) · Chemical Engineering Science · doi:10.1016/0009-2509(93)80328-n · Cited by 280
Experimental study of gas‐induced liquid‐flow structures in bubble columns
Degaleesan, S., Dudukovic, M., & Pan, Y. (2001) · AIChE Journal · doi:10.1002/aic.690470904 · Cited by 225
Reilly, I. G., Scott, D. S., Debruijn, T. J. W., & Macintyre, D. (1994) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450720102 · Cited by 211
Self-citationTwo-Phase Bubble Columns: A Comprehensive Review
Besagni, G., Inzoli, F., & Ziegenhein, T. (2018) · ChemEngineering · doi:10.3390/chemengineering2020013 · Cited by 190
“When using active compounds, the bubble size distribution changes because of coalescence suppression, and a decrease in db is expected (along with an increase in εG) [8,38,56,80,108,127,149,161, 234,241,253,270,271].”
BackgroundMethodInfluentialGas‐holdup measurements in bubble columns using computed tomography
Kumar, S. B., Moslemian, D., & Duduković, M. P. (1997) · AIChE Journal · doi:10.1002/aic.690430605 · Cited by 186
Mass transfer and bubble size in a bubble column under pressure
Wilkinson, P. M., Haringa, H., & Van Dierendonck, L. L. (1994) · Chemical Engineering Science · doi:10.1016/0009-2509(93)e0022-5 · Cited by 178
Krishna, R., Wilkinson, P. M., & Van Dierendonck, L. L. (1991) · Chemical Engineering Science · doi:10.1016/0009-2509(91)80042-w · Cited by 167
Kantarci, N., Ulgen, K. O., & Borak, F. (2005) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450830417 · Cited by 34
Metadata
- Authors
- Reilly, I. G., Scott, D. S., De Bruijn, T., Jain, A., & Piskorz, J.
- Venue
- The Canadian Journal of Chemical Engineering
- Publisher
- Wiley
- Published
- 1986-10
- Volume
- 64
- Issue
- 5
- Pages
- 705-717
- ISSN
- 0008-4034 (ISSN-L)
- 1939-019X
- OpenAlex
- W2027409047
- Cited by
- 145
- References
- 2
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.