CoChat

Gait Speed and Dependence in Activities of Daily Living in Older Adults With Severe Aortic Stenosis

Open access
Green, Philip, Woglom, Abigail E., Genereux, Philippe, Maurer, Mathew S., Kirtane, Ajay J., Hawkey, Marian, Schnell, Susan, Sohn, Jeanie, Moses, Jeffrey W., Leon, Martin B., Smith, Craig R., Williams, Mathew, Kodali, Susheel · 2012 · Clinical Cardiology
Cited by 68

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Background: In the transcatheter aortic valve replacement era, characterization of functional status in older adults with aortic stenosis (AS) is essential. Gait speed (GS) is emerging as a marker of frailty and predictor of outcomes in older adults undergoing cardiovascular intervention. The objective of this study was to delineate the prevalence of slow GS, evaluate the association of GS with factors used in standard cardiovascular assessments, and evaluate the association of GS with dependence in activities of daily living (ADLs) in older adults with AS. Hypothesis: We hypothesized that gait speed would not be associated with clinical factors, but would be associated with ADLs. Methods: We evaluated GS, ADLs dependence, and Society of Thoracic Surgery score along with clinical and functional assessments in 102 older adults with AS being evaluated for transcatheter valve. Gait speed <0.5 m/s was considered slow, and GS ≥0.5 m/s was considered preserved. We assessed the association of covariates with GS as well as with ADLs dependence. Results: Median GS was 0.37 m/s (interquartile range, 0.0–0.65 m/s). Sixty‐four (63%) subjects had slow GS. Of commonly employed clinical covariates, only prior coronary intervention and serum albumin were weakly associated with GS. However, GS was independently associated with ADLs dependence (Odds ratio: 1.52 [1.21‐1.91] for every 0.1 m/s decrease in GS; P = 0.0003). Conclusions: Although the prevalence of slow GS in a population of elderly patients with severe AS being screened for transcatheter valve was high, there were only weak associations between GS and other risk stratifying tools. The strong association between GS and dependent functional status suggests that assessment of gait speed is a useful, objectively measurable, risk stratification tool in this population. Dr. Maurer is supported by a grant from the NIH/NIA AG036778‐02. The other authors have no funding, financial relationships, or conflicts of interest to disclose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/clc.21974

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

Metadata

Authors
Green, P., Woglom, A. E., Genereux, P., Maurer, M. S., Kirtane, A. J., Hawkey, M., Schnell, S., Sohn, J., Moses, J. W., Leon, M. B., Smith, C. R., Williams, M., & Kodali, S.
Venue
Clinical Cardiology
Publisher
Wiley
Published
2012-02-13
Volume
35
Issue
5
Pages
307-314
ISSN
  • 0160-9289 (ISSN-L)
  • 1932-8737
OpenAlex
W2151966905
Cited by
68
References
23
FWCI
4.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.