Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Prevalence and Prognostic Value of Subclinical Left Ventricular Systolic Dysfunction by Global Longitudinal Strain in a Community-Based Cohort

Open access
Russo, Cesare, Jin, Zhezhen, Elkind, Mitchell S.V., Rundek, Tatjana, Homma, Shunichi, Sacco, Ralph L., Di Tullio, Marco R.·2014·European Journal of Heart Failure

Abstract

Aims: Global longitudinal strain (GLS) assessed by speckle-tracking echocardiography has been proposed as a parameter able to reflect early changes in left ventricular systolic function at a stage when left ventricular ejection fraction (LVEF) is still normal. This study aimed at assessing prevalence and prognostic value of left ventricular systolic dysfunction (LVSD) assessed by echocardiographic speckle-tracking GLS in a community-based cohort. Methods and Results: Participants from the community-based prospective Northern Manhattan Study underwent two-dimensional transthoracic echocardiography as part of the Cardiovascular Abnormalities and Brain Lesions study. Left ventricular systolic function was assessed by LVEF and speckle-tracking GLS. Subjects were followed annually (mean = 4.8 ± 1.5 years) and incident vascular events (ischaemic stroke, myocardial infarction, and vascular death) were reviewed and adjudicated. Of the 708 study participants, 114 (16.1%) had abnormal GLS but normal LVEF (GLS-LVSD), 30 (4.2%) had abnormal LVEF (LVEF-LVSD), and 564 (79.7%) had normal GLS and LVEF (no-LVSD). In multivariate analysis, risk of events was significantly greater in GLS-LVSD [adjusted hazard ratio (HR) = 2.39, 95% confidence interval (CI) = 1.20–4.77] and in LVEF-LVSD (adjusted HR = 3.51, 95% CI = 1.25–9.88) compared with no-LVSD. Among participants with normal LVEF, lower GLS was significantly associated with events (adjusted HR/unit decrease = 1.15, 95% CI = 1.03–1.28) whereas LVEF was not (adjusted HR/unit decrease = 1.01, 95% CI = 0.94–1.07). The GLS prognostic value was incremental to risk factors and LVEF both in the overall population (chi-square change = 7.406, P = 0.006) and in participants with normal LVEF (chi-square change = 6.357, P = 0.012). Conclusion: In a community-based cohort, GLS-LVSD was four times more frequent than LVEF-LVSD. GLS-LVSD was a powerful and independent predictor of cardiovascular events. Left ventricular function assessment by GLS may improve cardiovascular risk stratification in subjects with normal LVEF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ejhf.154

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 252

Metadata

Authors
Russo, C., Jin, Z., Elkind, M. S. V., Rundek, T., Homma, S., Sacco, R. L., & Di Tullio, M. R.
Venue
European Journal of Heart Failure
Published
2014-09-11
Volume
16
Issue
12
Pages
1301-1309
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W1990777046
Cited by
252
References
42
FWCI
9.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.