The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Bandage‐Based Wearable Potentiometric Sensor for Monitoring Wound pH
Abstract
A new wearable electrochemical sensor for monitoring the pH of wounds is introduced. The device is based on the judicious incorporation of a screen‐printed pH potentiometric sensor into bandages. The fabrication of this sensor, which uses an electropolymerized polyaniline (PANi) conducting polymer for pH sensing, combines the screen‐printing fabrication methodology with all‐solid‐state potentiometry for implementation of both the reference and the working electrodes. The pH bandage sensor displays a Nernstian response over a physiologically relevant pH range (5.5–8), with a noteworthy selectivity in the presence of physiological levels of most common ions. The bandage‐embedded sensor can track pH fluctuations with no apparent carry‐over effect. The sensor displays good resiliency against mechanical stress, along with superior repeatability and reproducibility. The in vitro performance of the device was successfully evaluated using buffer solutions emulating the composition of a wound. The novel pH‐sensitive bandages facilitate new avenues towards the realization of telemedicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gurtner, G. C., Werner, S., Barrandon, Y., & Longaker, M. T. (2008) · Nature · doi:10.1038/nature07039 · Cited by 6,542
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationTattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Self-citationAnalysis of metabolites in sweat as a measure of physical condition
Mitsubayashi, K., Suzuki, M., Tamiya, E., & Karube, I. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80004-9 · Cited by 153
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationFlexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Smart wound dressings for wound healing
Dong, R., & Guo, B. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101290 · Cited by 959
Metadata
- Authors
- Guinovart, T., Valdés‐Ramírez, G., Windmiller, J. R., Andrade, F. J., & Wang, J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2014-03-13
- Volume
- 26
- Issue
- 6
- Pages
- 1345-1353
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2066874563
- Cited by
- 308
- References
- 4
- FWCI
- 10.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bandage‐Based Wearable Potentiometric Sensor for Monitoring Wound pH. https://app.cochat.ai/papers/10.1002/elan.201300558
- The paper
- Guinovart, T., Valdés‐Ramírez, G., Windmiller, J. R., Andrade, F. J., & Wang, J. (2014). Bandage‐Based Wearable Potentiometric Sensor for Monitoring Wound pH. Electroanalysis. https://doi.org/10.1002/elan.201300558
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.