The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Protease‐catalyzed incorporation of 18O into peptide fragments and its application for protein sequencing by electrospray and matrix‐assisted laser desorption/ionization mass spectrometry
Abstract
Proteins were digested in normal and highly 18 O‐enriched water using proteases commonly employed for protein sequencing. The extent of 18 O incorporation into the resulting peptide fragments was characterized by electrospray ionization (ESI) and matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry (MS). The endoproteinases trypsin, Lys‐C and Glu‐C incorporate two atoms of 18 O, resulting in a mass shift of +4 D for the peptide fragments. This indicates that, following proteolytic cleavage, peptide products continue to interact with these proteases and undergo repeated binding/hydrolysis cycles, resulting in complete equilibration of both oxygens in the carboxy terminus of the fragments with oxygen from solvent water. In contrast, chymotrypsin and Asp‐N incorporate only one atom of 18 O, resulting in a mass shift of +2 D, indicating that after the cleavage step these proteases do not accept the peptides as substrates. In addition, it was found that the proteases trypsin, Glu‐C, and Lys‐C exhibit minor or nontypical sequence specificities, resulting in unexpected peptide fragments. These fragments incorporate only one 18 O atom, indicating that they do not undergo further binding/hydrolysis cycles with the enzyme. Thus, it is possible to discriminate between enzyme‐typical peptide fragments with mass shifts of +4 D and nontypical fragments with mass shifts of only +2 D. Based on these observations, protein digest strategies are described for the generation of 1:1 ion doublets spaced either by 2 or 4 D. In addition, the C‐terminus of a protein can be identified by the absence of an ion doublet in the corresponding peptide fragment. In protein sequencing by mass spectrometry, digest protocols generating ion doublets provide the most clear‐cut analytical results for the recognition of ion series in ESI‐MS/MS and MALDI post‐source decay (PSD) product ion specta. Only the mass spectrometric fragment ions of a C‐terminal series show ion doublets spaced either by 2 or 4 D, whereas the fragment ions belonging to an N‐terminal series remain unshifted. This assignment unequivocally reveals the direction of the identified sequence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Peptide sequencing by matrix‐assisted laser‐desorption mass spectrometry
Spengler, B., Kirsch, D., Kaufmann, R., & Jaeger, E. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290060207 · Cited by 305
Desiderio, D. M., & Kai, M. (1983) · Biological Mass Spectrometry · doi:10.1002/bms.1200100806 · Cited by 158
Rose, K., Simona, M. G., Offord, R. E., Prior, C., Otto, B., & Thatcher, D. R. (1983) · Biochemical Journal · doi:10.1042/bj2150273 · Cited by 79
Murphy, R. C., & Clay, K. L. (1979) · Journal of Mass Spectrometry · doi:10.1002/bms.1200060709 · Cited by 66
Cited by
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Quantitative mass spectrometry in proteomics: a critical review
Bantscheff, M., Schirle, M., Sweetman, G., Rick, J., & Kuster, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1486-6 · Cited by 1,669
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Proteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of Adenovirus
Yao, X., Freas, A., Ramirez, J., Demirev, P. A., & Fenselau, C. (2001) · Analytical Chemistry · doi:10.1021/ac001404c · Cited by 759
Mass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 734
Sinz, A. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20082 · Cited by 648
Kirkpatrick, D. S., Gerber, S. A., & Gygi, S. P. (2005) · Methods · doi:10.1016/j.ymeth.2004.08.018 · Cited by 559
Medintz, I. L., Clapp, A. R., Brunel, F. M., Tiefenbrunn, T., Tetsuo Uyeda, H., Chang, E. L., Deschamps, J. R., Dawson, P. E., & Mattoussi, H. (2006) · Nature Materials · doi:10.1038/nmat1676 · Cited by 550
Huang, B. X., Kim, H.-Y., & Dass, C. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.05.004 · Cited by 527
Mass spectrometric-based approaches in quantitative proteomics
Ong, S. (2003) · Methods · doi:10.1016/s1046-2023(02)00303-1 · Cited by 451
Ong, S.-E., Kratchmarova, I., & Mann, M. (2003) · Journal of Proteome Research · doi:10.1021/pr0255708 · Cited by 432
Proteomics: a pragmatic perspective
Mallick, P., & Kuster, B. (2010) · Nature Biotechnology · doi:10.1038/nbt.1658 · Cited by 430
Mirgorodskaya, O. A., Kozmin, Y. P., Titov, M. I., K�rner, R., S�nksen, C. P., & Roepstorff, P. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000730)14:14<1226::aid-rcm14>3.0.co;2-v · Cited by 368
Adipokines: A treasure trove for the discovery of biomarkers for metabolic disorders
Lehr, S., Hartwig, S., & Sell, H. (2012) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201100052 · Cited by 352
Protein identification methods in proteomics
Gevaert, K., & Vandekerckhove, J. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1145::aid-elps1145>3.0.co;2-z · Cited by 338
Proteomics of Integral Membrane ProteinsTheory and Application
Speers, A. E., & Wu, C. C. (2007) · Chemical Reviews · doi:10.1021/cr068286z · Cited by 325
18 O Labeling: a tool for proteomics
Stewart, I. I., Thomson, T., & Figeys, D. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.525 · Cited by 327
Quantification in Proteomics through Stable Isotope Coding: A Review
Julka, S., & Regnier, F. (2004) · Journal of Proteome Research · doi:10.1021/pr0340734 · Cited by 320
Münchbach, M., Quadroni, M., Miotto, G., & James, P. (2000) · Analytical Chemistry · doi:10.1021/ac000265w · Cited by 280
Proteomic Analysis of Formalin-fixed Prostate Cancer Tissue
Hood, B. L., Darfler, M. M., Guiel, T. G., Furusato, B., Lucas, D. A., Ringeisen, B. R., Sesterhenn, I. A., Conrads, T. P., Veenstra, T. D., & Krizman, D. B. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500102-mcp200 · Cited by 278
Buschow, S. I., van Balkom, B. W. M., Aalberts, M., Heck, A. J. R., Wauben, M., & Stoorvogel, W. (2010) · Immunology & Cell Biology · doi:10.1038/icb.2010.64 · Cited by 275
Quantitative Mass Spectrometry-Based Proteomics: An Overview
Rozanova, S., Barkovits, K., Nikolov, M., Schmidt, C., Urlaub, H., & Marcus, K. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-1024-4_8 · Cited by 275
Stable isotope labelling methods in mass spectrometry-based quantitative proteomics
Chahrour, O., Cobice, D., & Malone, J. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.04.013 · Cited by 267
Methods for samples preparation in proteomic research
Bodzon-Kulakowska, A., Bierczynska-Krzysik, A., Dylag, T., Drabik, A., Suder, P., Noga, M., Jarzebinska, J., & Silberring, J. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.10.040 · Cited by 254
Protein disulfide bond determination by mass spectrometry
Gorman, J. J., Wallis, T. P., & Pitt, J. J. (2002) · Mass Spectrometry Reviews · doi:10.1002/mas.10025 · Cited by 258
Quantitative Proteomics by Metabolic Labeling of Model Organisms
Gouw, J. W., Krijgsveld, J., & Heck, A. J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r900001-mcp200 · Cited by 151
Proteolytic Origin of the Soluble Human IL-6R In Vivo and a Decisive Role of N-Glycosylation
Riethmueller, S., Somasundaram, P., Ehlers, J. C., Hung, C.-W., Flynn, C. M., Lokau, J., Agthe, M., Düsterhöft, S., Zhu, Y., Grötzinger, J., et al. (2017) · PLOS Biology · doi:10.1371/journal.pbio.2000080 · Cited by 135
Towards comprehensive and quantitative proteomics for diagnosis and therapy of human disease
Cifani, P., & Kentsis, A. (2017) · PROTEOMICS · doi:10.1002/pmic.201600079 · Cited by 101
Yadav, R. P., Patel, A. K., & Jagannadham, M. V. (2011) · Process Biochemistry · doi:10.1016/j.procbio.2011.05.013 · Cited by 32
Metadata
- Authors
- Schnölzer, M., Jedrzejewski, P., & Lehmann, W. D.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1996-01
- Volume
- 17
- Issue
- 5
- Pages
- 945-953
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2016707540
- Cited by
- 295
- References
- 5
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.