CoChat

In‐capillary approach to eliminate SDS interferences in antibody analysis by capillary electrophoresis coupled to mass spectrometry

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Capillary electrophoresis is an important technique for the characterization of monoclonal antibodies (mAbs), especially in the pharmaceutical context. However, identification is difficult as upscaling and hyphenation of used methods directly to mass spectrometry is often not possible due to separation medium components that are incompatible with MS detection. Here a CE‐MS method for the analysis of mAbs is presented analyzing SDS‐complexed samples. To obtain narrow and intensive peaks of SDS‐treated antibodies, an in‐capillary strategy was developed based on the co‐injection of positively charged surfactants and methanol as organic solvent. For samples containing 0.2% (v/v) of SDS, recovered MS peak intensities up to 97 and 95% were achieved using cetyltrimethylammonium bromide or benzalkonium chloride, respectively. Successful removal of SDS was shown in neutral coated capillaries but also in a capillary with a positively charged coating applying reversed polarity. The usefulness of this in‐capillary strategy was demonstrated also for other proteins and for antibodies dissolved in up to 10% v/v SDS solution, and in other SDS‐containing matrices, including the sieving matrix used in a standard CE‐SDS method and gel‐buffers applied in SDS‐PAGE methods. The developed CE‐MS approaches enable fast and reproducible characterization of SDS‐complexed antibodies.

Overview

Integrity signals

Registry

Crossref · 10.1002/elps.201600464

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 34 references

Research works printed but not linked: 2

  1. Heftmann E., 2004, Chromatography, 633
  2. 10.1002/1522-2683(200109)22:17<3813::AID-ELPS3813>3.0.CO;2-D · doi:10.1002/1522-2683(200109)22:17<3813::aid-elps3813>3.0.co;2-d

Cited by

Metadata

Authors
Sánchez‐Hernández, L., Montealegre, C., Kiessig, S., Moritz, B., & Neusüß, C.
Affiliations
  • Hochschule Aalen (DE)
  • F. Hoffmann-La Roche AG (CH)
Corresponding author
Neusüß, Christian
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2017-02-02
Volume
38
Issue
7
Pages
1044-1052
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2564157347
Cited by
29
References
33
Citations by year
2024: 3 · 2023: 2 · 2022: 4 · 2021: 7 · 2020: 3 · 2019: 5 · 2018: 4 · 2017: 1
FWCI
1.60
Type
journal article
Language
en
Open access
closed
Locations
  • Electrophoresis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
monoclonal antibodies, capillary electrophoresis-mass spectrometry, cetyltrimethylammonium bromide, benzalkonium chloride, reversed polarity, protein characterization
MeSH terms
Antibodies, Monoclonal, Sodium Dodecyl Sulfate, Mass Spectrometry, Reproducibility of Results, Electrophoresis, Capillary

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.