Sensor systems for bioprocess monitoring
The DOI matches its Crossref record; 230 of the 230 references it cites were found in a registry or an index.
Abstract
The ability to measure all process variables is of great importance in the field of bioprocess monitoring and control, and continuous, real‐time measurements are highly desired. The more complete and real‐time the measurements are, the more stable, reproducible, and efficient the process can be, leading to reproducibly high‐quality products. This additional information allows the operator to better document the entire process. The process analytical technologies initiative of the US Food and Drug Administration is strongly related to the analysis and control of biopharmaceutical processes. The aim of the initiative is to create processes, generating products of ensured quality by measuring quality‐related process variables. The quality of the product is enhanced by a deep understanding of the process, which is enabled by an effective and suitable sensor system. The aim of this review is to provide an overview of current and emerging sensors for bioprocess monitoring. Sensors directly interfaced to bioreactors for measuring important variables from the gas phase, such as oxygen and carbon dioxide concentration, are discussed, as well as sensors for the monitoring of the biomass concentration and morphology and of the changing medium composition. Furthermore, sensor systems are discussed. These involve sensors (especially biosensors) that are not implemented directly inside the bioreactor but rather are used in conjunction with sample‐taking systems such as flow injection analysis. A major focus is given to spectroscopic sensors, which are noninvasive and offer interesting options for a simultaneous analysis of various compounds. Since data handling is extremely important for this kind of sensor, chemometrics are also included. Soft sensors are discussed as technology that allows a user to incorporate more process data as it become available. Finally, the current state of disposable sensor technology is presented. These sensors are needed for the growing area of disposable and continuous biomanufacturing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Items 201–230 of 230
Different approaches to multivariate calibration of nonlinear sensor data
Dieterle, F., Busche, S., & Gauglitz, G. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2652-8 · Cited by 22 · cited 1×
“Neural networks are a completely different concept to provide quantitative on-line prediction of process variables based on spectroscopic methods [215,216].”
BackgroundProcess analytical sensors and image‐based techniques for single‐use bioreactors
Bluma, A., Höpfner, T., Prediger, A., Glindkamp, A., Beutel, S., & Scheper, T. H. (2011) · Engineering in Life Sciences · doi:10.1002/elsc.201000191 · Cited by 22 · cited 15×
“PAT is a regulatory initiative introduced by the FDA to improve the understanding of production processes and to increase the quality of the final product by building this quality into the entire production process.”
BackgroundSelf-citationAn In-Line Flow Injection Optical Biosensor for Real-Time Bioprocess Monitoring
Bracewell, D. G., Gill, A., & Hoare, M. (2002) · Food and Bioproducts Processing · doi:10.1205/09603080252938690 · Cited by 21 · cited 1×
“Other reviews focus on specific biosensor classes, including calorimetric [52, 55–57], optical [39, 41], and electrochemical biosensors [38, 43, 44].”
BackgroundLüder, C., Lindner, P., Bulnes‐Abundis, D., Lu, S. M., Lücking, T. H., Solle, D., & Scheper, T. H. (2014) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.14.13 · Cited by 20 · cited 1×
“A recent paper reports on the combination of an ISM with MIR measurement to obtain reliable estimates of the process state of a CHO cell cultivation, as well as the establishment of a process control loop for substrate feed and optimal harvest [163].”
BackgroundSelf-citationMerten, O.-W., Palfi, G. E., Staheli, J., & Steiner, J. (1987) · PubMed · Cited by 20
Determination of Cell Concentration and Characterization of Cells
Reardon, K. F., & Scheper, T. H. (2001) · Wiley eBooks · doi:10.1002/9783527620999.ch6c · Cited by 18
Self-citationRecombinant Protein Production in Yeast: Methods and Protocols
Ergün, B. G., Hüccetoğulları, D., Öztürk, S., AKDUR, E. Ç., & Çalík, P. (2012) · Methods in molecular biology · doi:10.1007/978-1-61779-770-5 · Cited by 18
Rhee, J. I., Ritzka, A., & Scheper, T. H. (2004) · Biotechnology and Bioprocess Engineering · doi:10.1007/bf02942286 · Cited by 18
Self-citationPark, J., & Kim, H. (1990) · Biotechnology and Bioengineering · doi:10.1002/bit.260360713 · Cited by 17 · cited 3×
“Another approach uses the enzymes glucose/fructose oxidoreductase and gluconolactonase, immobilized upon a pH electrode, which determines the production of hydrogen ions resulting from the enzymatic turnover in presence of glucose [51, 58, 59].”
BackgroundMethodApplication of an enzyme thermistor for the determination of glucose in complex fermentation media
Wehnert, G., Sauerbrei, A., Bayer, T., Scheper, T., Schügerl, K., & Herold, T. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83759-9 · Cited by 17 · cited 4×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodSelf-citationMilligan, M., Lewin‐Koh, N., Coleman, D., Arroyo, A., & Saucedo, V. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25161 · Cited by 16 · cited 1×
“Pilot tests, spiking experiments, and data from experimental design allow one to construct premodels, which can be adjusted and validated by process data [213, 214].”
MethodOptical Inline Measurement Procedures for Counting and Sizing Cells in Bioprocess Technology
Rudolph, G., Lindner, P., Bluma, A., Joeris, K., Martínez, G., Hitzmann, B., & Scheper, T. H. (2009) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2009_12 · Cited by 14
Self-citationA new version of an in situ sampling system for bioprocess analysis
Hilmer, J., & Scheper, T. (1996) · Acta Biotechnologica · doi:10.1002/abio.370160216 · Cited by 14 · cited 1×
“Both probe types must provide a representative, stable sample stream with minimal time delay [2, 19, 20].”
BackgroundSelf-citationOnline‐Infrarotspektroskopie in der Bioprozessanalytik
Haake, C., Landgrebe, D., Scheper, T. H., Rhiel, M. H., & Rhiel, M. H. (2009) · Chemie Ingenieur Technik · doi:10.1002/cite.200900042 · Cited by 13
Self-citationAdvanced methods of process computer control for industrial processes
Isermann, R. (1981) · Computers in Industry · doi:10.1016/0166-3615(81)90046-4 · Cited by 12
Multivariate Curve Resolution – Integration von Wissen in Chemometrische Modelle
Kessler, W., & Kessler, R. W. (2010) · Chemie Ingenieur Technik · doi:10.1002/cite.200900176 · Cited by 12 · cited 1×
“Insertion of constraints to a PCA offers the possibility to monitor the course of different unspecific process variables, represented by the most relevant changes in the spectra [200].”
BackgroundAn automatic aseptic bioreactor sampling system
Seifert, G. K. E., & Matteau, P. P. (1988) · Biotechnology and Bioengineering · doi:10.1002/bit.260320713 · Cited by 11 · cited 1×
“There are also automated systems [21, 22] that use multivalve systems to flush tubing with cleaning solution and hot steam for sterilization after each sample-removal step [23].”
BackgroundA novel fiber optic probe for on-line monitoring of biomass concentrations
Janelt, G., Gerbsch, N., & Buchholz, R. (2000) · Bioprocess and Biosystems Engineering · doi:10.1007/s004490050732 · Cited by 11
Austin, G. D., Sankhe, S. K., & Tsao, G. T. (1992) · Bioprocess and Biosystems Engineering · doi:10.1007/bf00386233 · Cited by 10 · cited 1×
“A common example for the analysis of ethanol or methanol is the Figaro sensor, based on tin dioxide semiconducting material [17, 18].”
BackgroundBiotechnology, 4: Measuring, modelling and control
(1992) · Journal of Biotechnology · doi:10.1016/0168-1656(92)90045-b · Cited by 10
Continuous monitoring of D-glucose and L-lactate by flow injection analysis
Haouz, A., & Stieg, S. (2002) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(01)00477-x · Cited by 9
Lee, S.-J., Saleemuddin, M., Scheper, T. H., Loos, H., & Sahm, H. (1994) · Journal of Biotechnology · doi:10.1016/0168-1656(94)90021-3 · Cited by 8 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodSelf-citationHemminga, M. A., & Visser, J. (2000) · Journal of Biotechnology · doi:10.1016/s0168-1656(99)00202-3 · Cited by 7 · cited 1×
“2 NMR spectroscopy Alternatively, NMR spectroscopy allows the direct measurement of different intracellular components such as metabolic intermediates, amino acids, ammonia, intracellular pH, Ca+ and Na+, adenosine-triphosphate, and NAD(P)H [2, 171, 172].”
BackgroundDetermination of pH Value in Biotechnology
Henkel, S., & Beutel, S. (2013) · Chemie Ingenieur Technik · doi:10.1002/cite.201200099 · Cited by 7 · cited 2×
“review possible electrodes, materials, and combinations [85].”
BackgroundAnalytical applications of Raman spectroscopy in the pharmaceutical field
Tensmeyer, L. G., & Heathman, M. A. (1989) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(89)80009-3 · Cited by 7
Online Monitoring of Biomass Accumulation in Recombinant Yeast Cultures
Palmer, S. M., & Kunji, E. R. S. (2012) · Methods in molecular biology · doi:10.1007/978-1-61779-770-5_14 · Cited by 7
Automatic whole broth multi-fermentor sampling
Reda, K. D., Thien, M. P., Feygin, I., Marcin, C., Chartrain, M. M., & Greasham, R. (1991) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/bf01575886 · Cited by 6 · cited 1×
“There are also automated systems [21, 22] that use multivalve systems to flush tubing with cleaning solution and hot steam for sterilization after each sample-removal step [23].”
BackgroundAn ethanol-auxostat with on-line gas sensing
M�hlemann, H. M., & Bungay, H. R. (1993) · Biotechnology Techniques · doi:10.1007/bf00156332 · Cited by 5 · cited 1×
“A common example for the analysis of ethanol or methanol is the Figaro sensor, based on tin dioxide semiconducting material [17, 18].”
BackgroundImage Analysis Based Real Time-Control of Glucose Concentration
Brückerhoff, T., Frerichs, J.-G., Joeris, K., Konstantinov, K., & Scheper, T. H. (2005) · Springer eBooks · doi:10.1007/1-4020-3103-3_117 · Cited by 3
Self-citationScheper, T. H. (1991) · Vieweg+Teubner eBooks · doi:10.1007/978-3-322-83738-7_3 · Cited by 1
Self-citation
Research works printed but not linked: 12
- R. W. Kessler 2006 Wiley‐VCH Weinheim
- Shuk P., 2010, Process zirconia oxygen analyzer‐state of art. tm‐Technisches Messen Plattform für Methoden, Systeme und Anwendungen der Messtechnik., 77, 19
- Pohlscheidt M., 2009, Bioprocess and Fermentation Monitoring, in Encyclopedia of Industrial Biotechnology
- Ruzicka J., 1988, Chemical Analysis
- Ulber R., 2000, Academic Press, Enyclopedia of Microbiology, 567
- Glindkamp A., 2009, Sensors in disposable bioreactors status and trends, Adv. Biochem. Eng. Biotechnol., 115, 145
- Henriques J. G., 2010, Optical Sensor Systems in Biotechnology, 29
- Card C., 2008, Near‐infrared spectroscopy for rapid, simultaneous monitoring, BioProcess Int., 6, 58
- Moretto J., 2011, Process Raman spectroscopy for in‐line CHO cell culture monitoring, Am. Pharmaceut. Rev., 14, 18
- Lottspeich F., 2006, Bioanalytik
- Logan D. W., 2011, BMC Proc, P57
- Shaw A. D., 1999, Advances in Biochemical Engineering and Biotechnology, 83
Cited by
Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04635 · Cited by 341
Digital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
“In the gas phase, the commonly used sensing system consists of semiconducting, electrochemical, and paramagnetic sensors, which can be applied to oxygen and carbon dioxide measurements [185,186].”
BackgroundMethodClaßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
“It includes a gas (aeration), a liquid (growth medium), and a solid phase (cells) [5].”
BackgroundInfluentialSelf-citationProcess Analytical Technologies – Advances in bioprocess integration and future perspectives
Gerzon, G., Sheng, Y., & Kirkitadze, M. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114379 · Cited by 176
Blueprints for Biosensors: Design, Limitations, and Applications
Carpenter, A. C., Paulsen, I. T., & Williams, T. C. (2018) · Genes · doi:10.3390/genes9080375 · Cited by 183
“This involves the sampling of large scale biological processes such as beer/wine fermentations, garbage degradation, or bio-remediation [13,14].”
Background
Metadata
- Authors
- Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K.
- Affiliations
- Leibniz University Hannover (DE)
- Colorado State University (US)
- Corresponding author
- Solle, Dörte
- Venue
- Engineering in Life Sciences
- Publisher
- Wiley
- Published
- 2015-05-12
- Volume
- 15
- Issue
- 5
- Pages
- 469-488
- ISSN
- 1618-0240 (ISSN-L)
- 1618-2863
- OpenAlex
- W2085488202
- Semantic Scholar
- d24fffc6c68def0606d462a8628ed3175d254e61
- Cited by
- 224
- References
- 230
- Citations by year
- 2026: 27 · 2025: 22 · 2024: 17 · 2023: 17 · 2022: 23 · 2021: 23 · 2020: 22 · 2019: 24 · 2018: 14 · 2017: 22 · 2016: 10 · 2015: 3
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Engineering in Life Sciences (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Fluid Dynamics and Mixing
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- bioprocess monitoring, real-time process analysis, oxygen sensors, CO2 sensor, biosensors, flow injection analysis, spectroscopic sensors, chemometrics, soft sensors, disposable sensors, biopharmaceutical manufacturing, continuous biomanufacturing, quality by design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.